RaySafe Solo Specifications
1 / 5ページ

{{requestButtons}}

カタログの抜粋

RaySafe Solo  Specifications - 1

RaySafe Solo Specifications

カタログの1ページ目を開く
RaySafe Solo  Specifications - 2

RAYSAFE SOLO GENERAL EXPOSURE NEEDED One RESET Automatic DETECTOR CABLE LENGTH 2 and 10 m (6.5 and 33 ft) PATENT Germany DE69430268.6-08 SIZE BASE UNIT WEIGHT POWER OFF POWER SOURCE BATTERY TIME READ OUT Rechargeable 7.4 V Li-on battery 201 - 401hours (depending on detector and if Bluetooth is used) Three row alphanumerical backlit display with four digits numerical resolution RANGE mA UNCERTAINTY mA RANGE mAs UNCERTAINTY mAs MAX LOAD REPRODUCIBILITY OVER VOLTAGE PROTECTION EXPOSURE TIME RANGE UNCERTAINTY PULSE RANGE PEAK TRIG LEVEL PULSE RATE RANGE mAs PER PULSE RANGE SIZE...

カタログの2ページ目を開く
RaySafe Solo  Specifications - 3

RAYSAFE SOLO DOSE SIZE DETECTOR WEIGHT DOSE (R/F LOW) RANGE TRIG LEVEL SIZE DETECTOR WEIGHT RANGE TRIG LEVEL UNCERTAINTY DOSE (R/F HIGH) RANGE TRIG LEVEL RANGE MIN. PEAK TRIG LEVEL UNCERTAINTY 10 nGy/s –1 mGy/s (70 µR/min – 7 R/min) MIN. PEAK TRIG LEVEL RANGE MIN. PEAK TRIG LEVEL UNCERTAINTY RANGE UNCERTAINTY PEAK TRIG LEVEL (DENT LOW) PEAK TRIG LEVEL (DENT HIGH) 10 % or ± 0.2 mm Al (at signal levels above 1/1000 of max dose rate for selected sensor) 2 % (for total filtrations from 2.5 mm Al up to 15 mm Al or equivalent, Active Compensation) 0.8 mA, 70 kV, 50 cm (19.7 in), no added filtration...

カタログの3ページ目を開く
RaySafe Solo  Specifications - 4

RAYSAFE SOLO LIGHT SIZE DETECTOR 117 x 22 x 12 mm WEIGHT DOSE BEAM QUALITITES RANGE TRIG LEVEL UNCERTAINTY Mo/Mo, Mo/Al, Mo/Rh, Rh/Rh, Rh/Al, W/Rh, WAg 5 pGy - 9999 Gy (0.5 mR - 9999R) 10 pGy/s (70 mR/min) 5 % or ± 5 pGy (0.5 mR) (20 - 40 kV: Mo/Mo 22 - 49 kV: Mo/Al, Rh/Rh, Rh/Al 22 - 40 kV: Mo/Rh, W/Rh, W/Ag, 0 - 2.5 mm Al added filtration, Active Compensation:' (1) Definition: Paddle = 0.1 mm Al Note! Variation in paddle thickness and homogeneity may affect kV results. To achieve the most accurate result, kV measurements without paddle is recommended. (2) HVL is an option to RaySafe...

カタログの4ページ目を開く
RaySafe Solo  Specifications - 5

RAYSAFE UNCERTAINTY DEFINITION The expanded uncertainty is stated as the combined uncertainty of measurement multiplied by the coverage factor k=2, which assuming a normal distribution has a coverage probability of 95 % (complies with GUM by ISO (1995, ISBN 92-67-10188-9)). Instrument specifications are subject to purchased configuration. All specifications may change without not

カタログの5ページ目を開く

Fluke Health Solutionsのすべてのカタログと技術パンフレット

  1. ESA612

    6 ページ

  2. PS320

    5 ページ

  3. Impulse 6000D/7000DP

    15 ページ

  4. 190M

    8 ページ

  5. ESA615

    7 ページ

  6. Gas flow analyzer

    2 ページ

  7. ProSim 3 and 2

    7 ページ

  8. Product catalog

    40 ページ

  9. IDA-6 Flyer

    1 ページ

  10. ProSim SPOT Light

    4 ページ

  11. VT900A Datasheet

    6 ページ

  12. VT900A + VAPOR

    7 ページ

  13. ESA614 Datasheet

    6 ページ

  14. 451B

    3 ページ

  15. 451P

    3 ページ

  16. ProSim 4

    6 ページ

カタログアーカイブ

  1. QA-ES Series II

    4 ページ

  2. RAYSAFE 452

    9 ページ

  3. RaySafe Dose Viewer

    10 ページ

  4. RaySafe DXR+

    2 ページ

  5. BP Pump 2

    82 ページ

  6. RaySafe Solo

    5 ページ

  7. DPM1B

    2 ページ

  8. SigmaPace™ 1000

    8 ページ

  9. 965 Stack Monitor

    3 ページ

  10. INCU ?

    4 ページ

  11. 76-606DX

    2 ページ

  12. 07-CRXW and 07-QRX

    4 ページ

  13. RaySafe Xi

    8 ページ

  14. RaySafe X2

    12 ページ

  15. VT305

    4 ページ

  16. ProSim

    8 ページ