カタログの抜粋

ELISA ANALYZER THE OPEN ELISA AUTOMATION
カタログの1ページ目を開く
Open, Fully-Automated, Multi-Test, Multi-Batch, Immunoassay System
カタログの2ページ目を開く
TRITURUS® is a COMPLETELY OPEN AND FULLY AUTOMATED enzyme immunoassay analyzer. Using 96 WELL-PLATES, it can perform A VARIETY OF DIFFERENT ASSAYS on a group of samples and PROCESS SEVERAL CONSECUTIVE BATCHES SIMULTANEOUSLY. The instrument is designed to automatically perform ALL THE STEPS OF ANY MICROPLATE EIA TEST. TRITURUS® is a HIGHLY FLEXIBLE SYSTEM that offers the most efficient approach to automation of the ELISA workload without changing the laboratory’s normal workflow routine. Fully Automated TRITURUS® performs all steps of any microplate EIA assay, including: • Sample dilution...
カタログの3ページ目を開く
THE TRITURUS® ANALYZER: ITS SOFTWARE Complete Flexibility Worksheet Set-Up Status Screen Result Sheet
カタログの4ページ目を開く
TRITURUS ® offers complete flexibility in the processing of the laboratory’s workload without changing the routine workflow. With TRITURUS ® the laboratory manager has unlimited options to customize the test menu and the test protocols to fully meet the needs of any size clinical or research laboratory. The TRITURUS ® analyzer is known world wide for having the most innovative and easy to use operating software. A series of logical interactive screens guide the user through the program, thus allowing the processing of the complex daily ELISA workload in a comprehensive and absolutely user...
カタログの5ページ目を開く
MORE ABOUT TRITURUS®… Analyzer Self-Test Quality Control High Speed Processing Fixed Needles and/ or Disposable Tips High Precision Dispensing High Capacity Sample Identification and Bar Code Reading Multiple and/or Serial Sample Dilution Optimal Assay Performance
カタログの6ページ目を開く
Automatic self-test conveniently checks that all parts of the instrument are working properly. A status report is generated with the results. The Quality Control program records the evolution of data processed on TRITURUS ® . For each parameter selected, a line graph is shown for easy visual comparison of analytical runs. TRITURUS ® QC program uses Westgard Multirules procedure, a combination of decision criteria to decide whether an analytical run is in-control or out-of-control. The end-user can define the internal and external parameters. TRITURUS ® accepts an unlimited number of QC...
カタログの7ページ目を開く
TRITURUS® SPECIFICATIONS SAMPLE STATION Capacity Controls + Calibrators / test Reagents Sample identification Bar code types Batch verification Disposable tips Pipetting Carry-over INCUBATOR Capacity Temperature Stability Mixing WASHER Plate washer Wash type Wash solutions 92 samples per batch / 96 predilution tubes per batch / 4 plates per batch / 8 tests per batch / 4 batches simultaneously Up to 14 12 independent positions for reagents / 8 positions for sample diluents / Automatic calculation of required volumes Positive sample ID with built-in bar code reader Bar code types: Code 39,...