カタログの抜粋

Implants trauma Distal Humeral Locking Plates
カタログの1ページ目を開く
CAUTION: Federal Law (USA) restricts this device to sale by or on the order of a board certified physician. WARNING: If there is no sufficient bone healing, wrong or incomplete postoperative care, plate might break. All ITS plates are preformed anatomically as a matter of principle. If adjustment of the plate to the shape of the bone is required, this is possible by carefully bending gently in one direction once. Particular care is required when bending in the region of a plate hole, as deformation of the plate may lead to a failure of the locking mechanism. The plate must not be buckled or...
カタログの2ページ目を開く
1. Introduction P. 5 Preface P. 6 Screws P. 7 Properties P. 8 Indications & Contraindications P. 8 Time of operation 2. Surgical Technique P. 10 Pre-operative patient preparation P. 10 Access P. 11 Reduction P. 12 Placement of the screws P. 15 Postoperative treatment P. 15 Explantation 3. Information P. 17 Locking P. 17 Dotize® P. 18 Order list
カタログの3ページ目を開く
Preface The Distal Humeral Locking Plates are a proven osteosynthesis system for various fractures of the distal humerus. The special feature of these implants is the free choice of screw placement. The user is able to set any desired screw in any hole either locking or non-locking screw (except sliding hole). The free choice of screw angulation (+/- 15°, see page 17) provides an advantage in fracture treatment, especially in the case of complex fractures.
カタログの5ページ目を開く
Cortical Screw, locking, D=3.5mm, SH Spiral Drill, D=2.7mm, L=100mm, AO Connector Screwdriver, WS 2.5, self-holding sleeve Spiral Drill, D=2.7mm, L=100mm, AO Connector Screwdriver, WS 2.5, self-holding sleeve Cancellous Screw, locking, D=4.2mm, SH Spiral Drill, D=2.5mm, L=180mm, AO Connector Screwdriver, WS 2.5, self-holding sleeve Guide Wire, Steel, D=1.6mm, L=150mm, TR, with thread
カタログの6ページ目を開く
Properties Properties of the implant: • Plate material: Titanium • Material of screws: TiAl6V4 ELI • Easier removal of the implant after the fracture has healed • Improved fatigue strength of the implant • Reduced risk of cold welding • Reduced risk of inflammation and allergy • Multi-directional locking • Anatomical plate design • Sliding hole with compression option up to 4mm • Pointed proximal plate end for percutaneous insertion • Left/right version • Lengths, dorsolateral: 4, 5, 6, 7-hole • Lengths, medial: 8, 9, 10-hole
カタログの7ページ目を開く
♦ Supra- and diacondylar upper-arm fractures Contraindications: ♦ Severe osteoporosis ♦ Existing infections in the area of the fracture ♦ Strongly reduced general conditions • Obesity ♦ Lack of patient compliance Time of operation: ♦ Within the first hours of the trauma or in the following days ♦ If the operation is not primary, arm should be immobilized in a splint
カタログの8ページ目を開く
Surgical Technique
カタログの9ページ目を開く
♦ General or regional anaesthesia or combination can be used • Tourniquet ♦ Prone position o Access Posterior approach: ♦ Median incision in the ulnar rim on the distal upper arm above the olecranon • Exposure and retraction of the ulnar nerve • Depending on the type of fracture, olecranon osteotomy and retraction of the triceps • In the case of supracondylar fractures, it is possible to approach from the ulnar and radial side adjacent to the brachial triceps tendon
カタログの10ページ目を開く
Reduction • Temporary fixation of the plate using guide wires • Anatomical reduction of the fracture segments to the plate • Subsequent control under fluoroscopy Optionally, the plate can be stabilized using the ITS. Temporary Plate Holder (58164-150).
カタログの11ページ目を開く
Placement of the screws Use the drill guide, D=2.7/2.0mm (62202) to bore holes with the spiral drill D=2.7mm, L=100mm, AO Connector (61273-100) into the compression hole. Use the screwdriver, WS 2.5, self-holding sleeve (56252) to insert D=3.5mm cortical screws (32351-XX) of appropriate lengths determined previously with the depth gauge, solid small fragment screws (59022).
カタログの12ページ目を開く
Then, drill holes into a distal and proximal plate hole using the drill guide, D=2.7/2.0mm (62202) to bore holes with the spiral drill D=2.5mm, L=180mm resp. D=2.7mm, L=100mm, AO Connector (61253-180/61273-100). Use the screwdriver, WS 2.5, self-holding sleeve (56252) to insert the D=4.2mm cancellous screw (37422-XX-N) or D=3.5mm cortical screw, optionally locking (32351-XX/37351-XX-N) of appropriate lengths determined previously with the depth gauge, solid small fragment screws (59022).
カタログの13ページ目を開く
The remaining plate holes are then filled, with either locking or non-locking screws. Subsequent control of plate position under fluoroscopy.
カタログの14ページ目を開く
Postoperative treatment • Physical therapy • In case of poor bone quality or insecure fixation, movement fixator for a maximum of 6 weeks or upper-arm plaster cast for a maximum of 3 weeks • When a locking screw connection has been used, it is necessary to be aware that the diagnosis of non-union may be very delayed. Explantation If desired by the patient, the implant can be removed Removal should be performed at the earliest 6 months - 1 1/2 years later or after radiographic verification of the healed bone. The problem of cold welding was resolved by using a special surface treatment (for...
カタログの15ページ目を開く
o Locking Locking works because of: ♦ Screw material (TiALV) is slightly harder than plate material (Titanium Grade 2) • Screw head forms thread into the plate (no cutting) Benefits: • ± 15° and Locking • No pre threading • No cold welding • No debris • You can re-set the screw up to 3 times Dotize Type II anodization • Layer thickness 60-200nm Different colors + Film becomes an interstitial part of the titanium Implant surface remains sensitive to: Chipping - No visible cosmetic effect Peeling Discoloration Anodization Type II leads to following benefits* • Oxygen and silicon...
カタログの17ページ目を開く
Humeral Plate, Distal, 4-hole, Left, Dorsolateral Humeral Plate, Distal, 4-hole, Right, Dorsolateral Humeral Plate, Distal, 5-hole, Left, Dorsolateral Humeral Plate, Distal, 5-hole, Right, Dorsolateral Humeral Plate, Distal, 6-hole, Left, Dorsolateral Humeral Plate, Distal, 6-hole, Right, Dorsolateral Humeral Plate, Distal, 7-hole, Left, Dorsolateral Humeral Plate, Distal, 7-hole, Right, Dorsolateral Humeral Plate, Distal, 8-hole, Left, Medial Humeral Plate, Distal, 8-hole, Right, Medial Humeral Plate, Distal, 9-hole, Left, Medial Humeral Plate, Distal, 9-hole, Right, Medial Humeral Plate,...
カタログの18ページ目を開くI.T.S. のすべてのカタログと技術パンフレット
-
ufs
1 ページ
-
DHL
2 ページ
-
ITS
2 ページ
-
PHL
24 ページ
-
ACLS
20 ページ
-
CFN
32 ページ
-
OLS
24 ページ
-
PHLs
20 ページ
-
SR Sacral Rods
20 ページ
-
HCS
24 ページ
-
TOS Twist-Off Screw
20 ページ
-
TLS
20 ページ
-
PRS-RX
32 ページ
-
HLS
20 ページ
-
ES
20 ページ
-
SR
20 ページ
-
FL
24 ページ
-
CAS
40 ページ
-
FCN
20 ページ
-
HOL
24 ページ
-
FLS
24 ページ
-
PFL
20 ページ
-
DTL
24 ページ
-
HTO
24 ページ
-
PTL
32 ページ
-
DFL
32 ページ
-
SCL
32 ページ
-
SLS
24 ページ
-
CAL
20 ページ
-
DUL
24 ページ
-
CLS
28 ページ