カタログの抜粋

FL - 1

Implants trauma Fibula Locking Plate

カタログの1ページ目を開く
FL - 2

All ITS plates are preformed anatomically as a matter of principle. If adjustment of the plate to the shape of the bone is required, this is possible by carefully bending gently in one direction once. Particular care is required when bending in the region of a plate hole, as deformation of the plate may lead to a failure of the locking mechanism. The plate must not be buckled or bent several times. This is particularly important in the case of titanium implants, to prevent material fatigue and subsequent failure. The method of bending is the conscious responsibility of the operating doctor;...

カタログの2ページ目を開く
FL - 3

1. Introduction P. 5 Preface P. 6 Screws P. 7 Properties P. 8 Indications & Contraindications P. 8 Time of operation 2. Surgical Technique P. 10 Pre-operative patient preparation P. 10 Access P. 10 Reduction P. 11 Placement of the screws P. 15 Postoperative treatment P. 15 Explantation 3. Information P. 17 Locking P. 17 Dotize® P. 18 Order list P. 20 Reconditioning Manual P. 22 Notes

カタログの3ページ目を開く
FL - 5

Preface The Fibula Locking Plate is a proven osteosynthesis system for various distal fibula fractures. The special feature of this implant is the free choice of screw placement. The user is able to set any desired screw in any hole, either locking or non-locking screw (except oblong hole). The free choice of screw angulation (+/- 15°, see page 17) provides an advantage in fracture treatment, especially in the case of complex fractures.

カタログの5ページ目を開く
FL - 6

Cortical Screw, locking, D=3.5mm, SH Spiral Drill, D=2.7mm, L=100mm, AO Connector Screwdriver, WS 2.5, self-holding sleeve Spiral Drill, D=2.7mm, L=100mm, AO Connector Screwdriver, WS 2.5, self-holding sleeve Cancellous Screw, locking, D=3.5mm, SH Spiral Drill, D=2.0mm, L=100mm, AO Connector Screwdriver, WS 2.5, self-holding sleeve

カタログの6ページ目を開く
FL - 7

Properties Properties of the implant: • Plate material: Titanium • Material of screws: TiAl6V4 ELI • Easier removal of the implant after the fracture has healed • Improved fatigue strength of the implant • Reduced risk of cold welding • Reduced risk of inflammation and allergy • Multi-directional Locking • Anatomically shaped • Oblong-hole for optimal positioning and alignment of the fibula length • Pointed proximal plate end for percutaneous insertion • Left/right version • Plate lengths: 4, 6, 8, 10, 12-hole

カタログの7ページ目を開く
FL - 8

Indications, Contraindications & Time of operation Indications: • Dislocated ankle-fractures group B+C according to Weber (with or without comminuted zones) Existing infections in the fracture zone and operation area Common situations that do not allow osteosynthesis With advanced osteoporosis In cases of skin and soft tissue problems that prevent a tension-free skin closure Obesity Lack of patient compliance Time of operation: • Immediately after injury • After regression of the swelling

カタログの8ページ目を開く
FL - 10

Pre-operative patient preparation • Supine position • Primary Tourniquet • General or regional anesthesia Access Lateral access: • Skin incision above the centre of the fibula • The incision should be made 1-2cm away from the fracture so that the suture is not directly over the plate • After incision of the inferior extensor retinaculum (cruciform ligament) directly in front of the fibula the toe extensors and the variable peroneus tertius are retracted forwards 1 Reduction • Temporary fixation of the plate to the fibula shaft using forceps or temporary plate holder (58164-150) • Anatomical...

カタログの10ページ目を開く
FL - 11

Placement of the screws With the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100), drill through the drill giude, D=2.7/2.0mm (62202) into the long-hole. Determine appropriate length using the depth gauge, solid small fragment screws (59022). Insert the D=3.5mm cortical screw (32351-XX) with the screwdriver, WS 2.5, self-holding sleeve (56252). Advice: For optimal alignment of the plate with fibula length, we recommend to first occupy the oblong hole.

カタログの11ページ目を開く
FL - 12

Then using the spiral drill, D=2.5mm, L=100mm, AO Connector (61253-100) to drill through the drill guide, D=2.7/2.0mm (62202) into a distal plate hole. Determine appropriate length using the depth gauge, solid small fragment screws (59022). Insert the D=3.5mm locking cortical screw (37351-XX-N) with the screwdriver, WS 2.5, selfholding sleeve (56252).

カタログの12ページ目を開く
FL - 13

Using the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) drill through the drill guide, D=2.7/2.0mm (62202) into a shaft plate hole. Determine appropriate length using the depth gauge, solid small fragment screws (59022). Insert the D=3.5mm cortical screw (32351-XX) with the screwdriver, WS 2.5, self-holding sleeve (56252).

カタログの13ページ目を開く
FL - 14

The remaining plate holes are then filled, with either locking or non-locking screws. Subsequent control of plate position under fluoroscopy.

カタログの14ページ目を開く
FL - 15

Postoperative treatment • Splinted shank for 2 weeks • Physical therapy • 6-8 weeks rest • When a locking screw connection has been used, it is necessary to be aware that the diagnosis of a non-union may be very delayed. Explantation If desired by the patient, the implant can be removed. Removal should be performed at the earliest 6 months - 1 1/2 years later or after radiographic verification of the healed bone. The problem of cold welding was resolved by using a special surface treatment (for further information see page 17).

カタログの15ページ目を開く
FL - 17

Locking Locking works because: • Screw material (TiAlV) is slightly harder than plate material (Titanium Grade 2) • Screw head forms thread into the plate (no cutting) ± 15° and Locking No pre threading No cold welding No debris You can re-set the screw up to 3 times Dotize® Chemical process - anodization in a strong alkaline solution* Dotize Type II anodization • Layer thickness 2000-10 000nm + Film becomes an interstitial part of the titanium + Different colors - Implant surface remains sensitive to: Chipping Peeling Discoloration - No visible cosmetic effect Dotize® Type - II Anodization...

カタログの17ページ目を開く

I.T.S. のすべてのカタログと技術パンフレット

  1. ufs

    1 ページ

  2. DHL

    2 ページ

  3. ITS

    2 ページ

  4. PHL

    24 ページ

  5. ACLS

    20 ページ

  6. CFN

    32 ページ

  7. OLS

    24 ページ

  8. PHLs

    20 ページ

  9. SR Sacral Rods

    20 ページ

  10. HCS

    24 ページ

  11. TOS Twist-Off Screw

    20 ページ

  12. TLS

    20 ページ

  13. PRS-RX

    32 ページ

  14. HLS

    20 ページ

  15. ES

    20 ページ

  16. SR

    20 ページ

  17. CAS

    40 ページ

  18. FCN

    20 ページ

  19. HOL

    24 ページ

  20. FLS

    24 ページ

  21. PFL

    20 ページ

  22. DTL

    24 ページ

  23. HTO

    24 ページ

  24. PTL

    32 ページ

  25. DFL

    32 ページ

  26. SCL

    32 ページ

  27. SLS

    24 ページ

  28. CAL

    20 ページ

  29. DUL

    24 ページ

  30. CLS

    28 ページ

カタログアーカイブ

  1. SR Old

    20 ページ

  2. ES Old

    20 ページ

  3. CAS Old

    36 ページ

  4. CS

    16 ページ

  5. SN Old

    16 ページ

  6. FCN Old

    16 ページ

  7. DFL Old

    28 ページ

  8. FTN

    12 ページ

  9. PRS

    28 ページ

  10. PRL

    28 ページ

  11. UOL

    32 ページ

  12. SL

    16 ページ

  13. OHL

    24 ページ

  14. OL

    16 ページ

  15. DHL

    16 ページ

  16. PHL

    16 ページ

  17. CLS

    24 ページ