HTO - 1

Implants trauma High Tibia Osteotomy Plate

カタログの1ページ目を開く
HTO - 2

All ITS plates are preformed anatomically as a matter of principle. If adjustment of the plate to the shape of the bone is required, this is possible by carefully bending gently in one direction once. Particular care is required when bending in the region of a plate hole, as deformation of the plate may lead to a failure of the locking mechanism. The plate must not be buckled or bent several times. This is particularly important in the case of titanium implants, to prevent material fatigue and subsequent failure. The method of bending is the conscious responsibility of the operating doctor;...

カタログの2ページ目を開く
HTO - 3

1. Introduction P. 5 Preface P. 6 Screws P. 7 Properties P. 7 Instruments P. 8 Advantages of the „Closed Wedge“ Technique P. 8 Indications & Contraindications 2. Surgical Technique P. 10 Pre-operative patient preparation P. 10 Access P. 11 Exposure P. 12 Implantation P. 13 Compression instrument P. 15 Postoperative treatment P. 15 Explantation P. 15 Summary 3. Information P. 17 Locking P. 17 Dotize® P. 18 Order list P. 20 Reconditioning Manual P. 22 Notes

カタログの3ページ目を開く
HTO - 5

Preface The locking Tibia Head Plate is anatomically preshaped and is fixed laterally. The preshaping leads to reduced operation times since an intraoperative anatomical contouring no longer needs to be performed. All holes are occupied in a locking way thus ensuring an early ability to bear weight without any loss of correction.

カタログの5ページ目を開く
HTO - 6

37451-xx Cortical Screw, Locking, D=4.8mm 61408-225 Spiral DriLL, D=4.0mm, L=225mm, AO Connector Mill Mill MM lllllllllllllllllllllll III Mill Mill MM lllll III lllllllllllllll llll Mil MM lllllll^

カタログの6ページ目を開く
HTO - 7

Properties Properties of the material: • Plate material: Titanium • Material of screws: TiAl6V4 ELI • Easier removal of the implant after the fracture has healed • Improved fatigue strength of the implant • Reduced risk of cold welding • Reduced risk of inflammation and allergy Locking Anatomically contoured Left/right version Stable plate with ability to bear weight early on without loss of correction • Plate lenght: 6-hole Instruments Tension bolts: • Tension bolt A is fixed on the tibia slightly ventral to the plate • Tension bolt B is fixed in one of the two plate holes Compression...

カタログの7ページ目を開く
HTO - 8

Advantages of the „Closed Wedge“ Technique • • • • Fast osseous restoration times - 2 planar bony areas are apposed under compression Immediate load stability - 3 weeks partial weight bearing - then full weight bearing Adjusted correction angle and adjusted tibial slope are held exactly No loss of correction due to worse bone quality Indications & Contraindications Indications: • Tibia-head osteotomy with valgus („Closed Wedge“ Technique) • Femoral osteotomy with varus („Closed Wedge“ Technique) Existing infections in the fracture zone and operation area Common situations that do not allow...

カタログの8ページ目を開く
HTO - 10

Pre-operative patient preparation • Body position is the same as for arthroscopy, which is routinely performed before the osteotomy • Additionally, a roll is pushed under the bone in order to bend the knee to about 20° in order to protect the neurovascular structures in the hollow of the knee. Access • Lateral approach of about 6cm length at the height of the proximal tibia, viewed laterally at the centre of the lower leg, between tub. tibiae and palpable head of the fibula. • First, the lig. patellae is displayed, the anterior musculature of the tibia is transversely separated from the...

カタログの10ページ目を開く
HTO - 11

Exposure • Next, the guide wires for the osteotomy are drilled (check using fluoroscopy). • For this purpose an angle gauge (6820202-1) is used to display an accurate guidance for the D=3.2mm guide wire • First of all, the guide wire, steel, D=3.2mm, L=170mm (35324-170) is attached and fastened in the blind hole with the 0 mark using the appropriate fixation screw (6820202-2). • The second long guide wire, steel, D=3.2mm, L=228mm (35324-228) is subsequently drilled in, in such a way that both wires meet each other at the medial cortex of the tibia. • After checking the angle of the planned...

カタログの11ページ目を開く
HTO - 12

Implantation The locking plate is positioned laterally and then fastened to the head of the shin bone using the three screws running parallel to the articular surface. Use the drill guide, D=4.0mm (62401-88) to bore holes with the spiral drill, D=4.0mm, L=225mm, AO Connector (61408-225) into the proximal plate holes. Read off the required screw length at the calibrated spiral drill and insert D=4.8mm locking cortial screws (37481-XX), using the screwdriver, WS 3.5, conic, self-holding (56352-SH). Then fix the tension bolt, 4x13 (70102-40/13) in one of the two plate holes (see picture...

カタログの12ページ目を開く
HTO - 13

Compression instrument For the closure of the osteotomy, a compression device (70100) has been developed which engages two tension bolts. Through rotation of the T-handpiece the osteotomy can be closed tightly without any problems.

カタログの13ページ目を開く
HTO - 14

For the final positioning of the three distal plate holes, the compression instrument can be tilted without losing any tension, in a ventral or dorsal direction, in order to be able to insert the screws. Weight bearing stability is thus provided. The axis is now once more intraoperatively checked (if required, using computer navigation). The musculature is refixed onto the head of the tibia, a drain is put in place, and the wound closed.

カタログの14ページ目を開く
HTO - 15

Postoperative treatment • The drain is removed on the first postoperative day, and mobilisation is started with the patient. • After exposure to partial weight bearing for three weeks and in case of an uneventful course, the patient can start walking with full weight. • Osseous restoration is achieved after 4 - 6 weeks according to radiography. • Patients are discharged from treatment on average 6 - 7 weeks after the osteotomy has healed. • Thrombosis prophylaxis is carried out for 4 - 6 weeks. Explantation If desired by the patient, the implant can be removed. Removal should be performed...

カタログの15ページ目を開く

I.T.S. のすべてのカタログと技術パンフレット

  1. ufs

    1 ページ

  2. DHL

    2 ページ

  3. ITS

    2 ページ

  4. PHL

    24 ページ

  5. ACLS

    20 ページ

  6. CFN

    32 ページ

  7. OLS

    24 ページ

  8. PHLs

    20 ページ

  9. SR Sacral Rods

    20 ページ

  10. HCS

    24 ページ

  11. TOS Twist-Off Screw

    20 ページ

  12. TLS

    20 ページ

  13. PRS-RX

    32 ページ

  14. HLS

    20 ページ

  15. ES

    20 ページ

  16. SR

    20 ページ

  17. FL

    24 ページ

  18. CAS

    40 ページ

  19. FCN

    20 ページ

  20. HOL

    24 ページ

  21. FLS

    24 ページ

  22. PFL

    20 ページ

  23. DTL

    24 ページ

  24. PTL

    32 ページ

  25. DFL

    32 ページ

  26. SCL

    32 ページ

  27. SLS

    24 ページ

  28. CAL

    20 ページ

  29. DUL

    24 ページ

  30. CLS

    28 ページ

カタログアーカイブ

  1. SR Old

    20 ページ

  2. ES Old

    20 ページ

  3. CAS Old

    36 ページ

  4. CS

    16 ページ

  5. SN Old

    16 ページ

  6. FCN Old

    16 ページ

  7. DFL Old

    28 ページ

  8. FTN

    12 ページ

  9. PRS

    28 ページ

  10. PRL

    28 ページ

  11. UOL

    32 ページ

  12. SL

    16 ページ

  13. OHL

    24 ページ

  14. OL

    16 ページ

  15. DHL

    16 ページ

  16. PHL

    16 ページ

  17. CLS

    24 ページ