CAUTION: Federal Law (USA) restricts this device to sale by or on the order of a board certified physician. WARNING: If there is no sufficient bone healing, wrong or incomplete postoperative care, plate might break. All ITS plates are preformed anatomically as a matter of principle. If adjustment of the plate to the shape of the bone is required, this is possible by carefully bending gently in one direction once. Particular care is required when bending in the region of a plate hole, as deformation of the plate may lead to a failure of the locking mechanism. The plate must not be buckled or...

カタログの2ページ目を開く
PHL - 3

1. Introduction P. 5 Preface P. 6 Screws P. 7 Properties P. 8 Indications & Contraindications P. 8 Time of operation 2. Surgical Technique P. 10 Assembling of the percutaneous guide P. 10 Pre-operative patient preparation P. 11 Exposure P. 11 Reduction P. 12 Plate insertion P. 13 Intraoperative identification of screw length P. 14 Placement of the screws P. 18 Disassembling of the percutaneous guide P. 19 Optional fixation of soft tissue P. 19 Optional fixation in the shaft area with cerclage P. 19 Postoperative treatment P. 19 Explantation 3. Information P. 21 Locking P. 21 Dotize® P. 22...

カタログの3ページ目を開く
PHL - 5

Preface The newly developed Proximal Humeral Locking Plate enables the medical treatment of fractures in the joint area with an optional less invasive method. The special feature of this implant is the free choice of screw placement. The user is able to set any desired screw in any hole (except oblong hole). Especially with complex fractures the free choice of screw angle (+/- 15°, see page 21) has advantages in the fracture treatment.

カタログの5ページ目を開く
PHL - 6

Cortical Screw, Locking, D=3.5mm, SH Spiral Drill, D=2.7mm, L=220mm, AO Connector Screwdriver, WS 2.5, self-holding Cortical Screw, D=3.5mm Spiral Drill, D=2.7mm, L=220mm, AO Connector Screwdriver, WS 2.5, self-holding Cancellous Screw, locking, D=4.2mm, SH Spiral Drill, D=2.5mm, L=220mm, AO Connector Screwdriver, WS 2.5, self-holding Guide Wire, Steel, D = 1.6mm, L=260mm, TR, w. thread

カタログの6ページ目を開く
PHL - 7

Properties Properties of the material: • Plate material: Titanium • Material of screws: TiAl6V4 ELI • Easier removal of the implant after the fracture has healed • Improved fatigue strength of the implant • Reduced risk of cold welding • Reduced risk of inflammation and allergy • Multi-directional locking • Anatomical plate design • 6 proximal plate holes for optimal reconstruction of the humeral head • Oblong hole for optimal positioning and adjustment of the humeral length • K-Wire holes for preliminary plate fixation • Pointed distal plate end for percutaneous insertion • Lengths: 4, 7,...

カタログの7ページ目を開く
PHL - 8

Indications, Contraindications & Time of operation Indications: • All stable and unstable fractures with or without shaft involvement Severe osteoporosis Existing infections in the area of the fracture In cases of skin and soft tissue problems Obesity Lack of patient compliance Time of operation: • Primary as well as secondary after swelling subsides and after temporary

カタログの8ページ目を開く
PHL - 10

Assembling of the percutaneous guide 1 Pre-operative patient preparation • Positioning on a radiolucent surgical table • Semi-sitting angle of about 30° - 40°, shoulder should be freely moveable (optional shoulder table) • The arm should be freely moveable to allow fracture reduction • General anaesthesia, regional anaesthesia or combination can be u

カタログの10ページ目を開く
PHL - 11

Exposure Anterolateral access: • Skin incision parallel to the anterior acromion and extension 5cm distally in fiber direction of the M. deltoideus. • Detachment of the pars acromialis of the M. deltoideus. Reduction Anatomical reduction of the fracture under fluoroscopy.

カタログの11ページ目を開く
PHL - 12

Plate insertion • • • • Insert the plate, assembled on the percutaneous guide (recommended in Z position) Plate remains in constant contact with the bone and slide distally Align the proximal end of the plate on the Tuberculum majus Verify the correct plate position. Optional temporary fixation with guide wires, steel, D=1.6mm, L=260mm, TR, w. thread (35164-260) into proximal guide wire h

カタログの12ページ目を開く
PHL - 13

Intraoperative identification of screw length 1. Insert the depth gauge for humeral systems (59222) after drilling screw holes. Then, hook into the far medial cortices and read off the required screw length. 2. Drill screw holes under fluoroscopy guidance through the far medial cortices. Then, read off the required screw length at the calibrated spiral drill D=2.7mm, L=220mm (61273-220). Note: In the proximal area, the screw length is determined using the depth gauge, solid small fragment screws (59022).

カタログの13ページ目を開く
PHL - 14

Placement of the screws Fix the plate temporarily to the bone and drill with the spiral drill, D=2.7mm, L=220mm, AO Connector (61273-220) in the oblong hole. Drilling is performed through the D=2.8mm drill sleeve (118005-10) that was placed in the tissue protection sleeve (118005-8). Then, the drill sleeve is removed and a D=3.5mm cortical screw (32351-XX) (appropriate length measured before) is inserted through the tissue protection sleeve. Advice: For optimal positioning and adjustment of the humeral length, we recommend to first fill the oblong hole. Therefore there is a centric and...

カタログの14ページ目を開く
PHL - 15

Unscrew the clamping nut (118005-4) up to the black mark (see picture below), rotate the handle 180° and tighten the clamping nut by hand. Then using the spiral drill, D=2.5/2.7mm, L=220mm, AO Connector (61253-220/61273-220) to drill through the drill guide, D=2.7/2.0mm (62202) into a proximal hole. Use the screwdriver, WS 2.5 (56252-150) to insert a D=3.5mm locking cortical screw (37351XX-N) or a D=4.2mm locking cancellous screw (37422-XX-N) of appropriate length determined previously with the depth gauge, solid small fragment screws (59022).

カタログの15ページ目を開く
PHL - 16

Following unscrew the clamping nut (118005-4) up to the black mark (see picture below), rotate the handle 180° and tighten the clamping nut by hand. Then the shaft holes are occupied, optionally with locking or non-locking screws. Use the screwdriver, WS 2.5 (56252-150) to insert D=4.2mm locking cancellous screws (37422XX-N) or D=3.5mm cortical screws, optionally locking or non-locking (32351-XX/37351XX-N) of appropriate lengths determined previously.

カタログの16ページ目を開く

I.T.S. のすべてのカタログと技術パンフレット

  1. ufs

    1 ページ

  2. DHL

    2 ページ

  3. ITS

    2 ページ

  4. ACLS

    20 ページ

  5. CFN

    32 ページ

  6. OLS

    24 ページ

  7. PHLs

    20 ページ

  8. SR Sacral Rods

    20 ページ

  9. HCS

    24 ページ

  10. TOS Twist-Off Screw

    20 ページ

  11. TLS

    20 ページ

  12. PRS-RX

    32 ページ

  13. HLS

    20 ページ

  14. ES

    20 ページ

  15. SR

    20 ページ

  16. FL

    24 ページ

  17. CAS

    40 ページ

  18. FCN

    20 ページ

  19. HOL

    24 ページ

  20. FLS

    24 ページ

  21. PFL

    20 ページ

  22. DTL

    24 ページ

  23. HTO

    24 ページ

  24. PTL

    32 ページ

  25. DFL

    32 ページ

  26. SCL

    32 ページ

  27. SLS

    24 ページ

  28. CAL

    20 ページ

  29. DUL

    24 ページ

  30. CLS

    28 ページ

カタログアーカイブ

  1. SR Old

    20 ページ

  2. ES Old

    20 ページ

  3. CAS Old

    36 ページ

  4. CS

    16 ページ

  5. SN Old

    16 ページ

  6. FCN Old

    16 ページ

  7. DFL Old

    28 ページ

  8. FTN

    12 ページ

  9. PRS

    28 ページ

  10. PRL

    28 ページ

  11. UOL

    32 ページ

  12. SL

    16 ページ

  13. OHL

    24 ページ

  14. OL

    16 ページ

  15. DHL

    16 ページ

  16. PHL

    16 ページ

  17. CLS

    24 ページ