PRL
1 / 28ページ

{{requestButtons}}

カタログの抜粋

PRL - 1

PRL PROlock RADIUS LOCKING PLATE 2.0 emergency team for broken bones®

カタログの1ページ目を開く
PRL - 2

CONTENT Introduction 3 Properties 4 Indication & Contraindication 8 Time of Operation Surgical Technique Preface 8 Positioning of the Patient 9 Access Implantation 10 Postoperative Treatment 18 Explantation 18 Summary Information 10 18 Order Information 20 Locking 22 Dotize® 23 Sterilization Guidelines 24 Notes 26

カタログの2ページ目を開く
PRL - 3

Preface Preface: The development of the PROlock Radius Locking Plate 2.0 is based on the excellent results of the previous I.T.S. Radius Plates. Minimisation of the flexor tendon irritation due to anatomical plate design and rounded edges. Precise and rapid screw placement of the distal plate holes with predefined angles due to radiolucent drill guide. The special feature of this implant is the free choice of screw placement. So the user is able to set every desired screw in every hole (except long hole). 03

カタログの3ページ目を開く
PRL - 4

PROlock Radius Locking Plate 2.0 32271-XX Cortical Screw, D=2.7mm 61203-100 Spiral Drill, D=2.0mm, L=100mm, AO Connector 56095-70 Screwdriver, Torque, T9x70 37304-XX Cortical Stabilization Screw RH, D=3.0mm 61243-100 Spiral Drill, D=2.4mm, L=100mm, AO Connector 56095-70 Screwdriver, Torque, T9x70 37303-XX Cancellous Stabilization Screw RH, D=3.0mm 61203-100 Spiral Drill, D=2.0mm, L=100mm, AO Connector 56095-70 Screwdriver, Torque, T9x70 37241-XX Stabilization Screw RH, D=2.4mm 61183-100 Spiral Drill, D=1.8mm, L=100mm, AO Connector 56095-70 Screwdriver, Torque, T9x70 35164-150 Guide Wire,...

カタログの4ページ目を開く
PRL - 5

• Multidirectional Locking • Version left/right • Minimisation of the flexor tendon irritation due to anatomical plate design • K-Wire holes for preliminary plate fixation • Long hole for optimal positioning and adjustment of radius length • Optionally drill block • Plate material: Titanium • Easier removal after fracture has healed • Improved fatigue strength of Implant • Reduced risk of cold bonding • Reduced risk of Inflammation and allergy All ITS locking plates are anatomically pre-ccrtcurco. n- the unlikely oven: tra: :rc- cla:c "as to be formed to the bone please no:;cc :nat slight...

カタログの5ページ目を開く
PRL - 6

Advanced Properties PROlock 2.0: • Predefined angles of the distal holes 4 Version left 3 5 6 2 7 1 1 Version right 7 2 3 4 6 5 Hole number 1 2 3 4 5 6 7 06 Proximal/distal direction distal 15° proximal 5° proximal 5° proximal 5° distal 5° distal 5° distal 10° Ulnar/radial direction radial 8° radial 8° radial 3° ulnar 3° 0° radial 7° radial 13°

カタログの6ページ目を開く
PRL - 7

Drill Block Properties Left Right • Precise and rapid screw placement with predefined angles • Click mechanism for easy mounting and disassembly • Radiolucent • Allows for screw insertion through drill block • Color coding for left and right version Assembling • Slide the drill block to the distal end till it engages audible into the designated holes (see picture on the right, red marked) • In addition there is the possibility to fix the drill block with a K-Wire (see picture on the right, blue marked) • Depth gauge, PROlock II in single-hand design (59026) can be pushed through the drill...

カタログの7ページ目を開く
PRL - 8

Indication & Contraindication Indication: • Complex intra-articular fractures of the distal radius with comminuted zone • Complex extra-articular fractures of the distal radius with comminuted zone • Corrective osteotomy of the distal radius Contraindication: • Very advanced osteoporosis with soft bones • Disintegration of the radius-joint surfaces to the extent that there is no support for screws Time of Operation Time of Operation: • Acut, on the day of the accident • After swelling has subsided (5-10 days) In the case of additional questions concerning the wrist surface, a CT scan can be...

カタログの8ページ目を開く
PRL - 9

Positioning of the Patient Positioning of the Patient: • The patient is placed in the supine position with pneumatic partial deprivation of blood supply • The hand is positioned on a X-ray transparent surgical hand table 09

カタログの9ページ目を開く
PRL - 10

Access The skin incision is performed volarly on the distal forearm above the tendon of the flexor carpi radialis and reaching to the crease of the wrist (FCR-approach). Splitting of the deep fascia of the forearm, releasing the pronator quadratus muscle from the distal radius beginning at the radial edge. Implantation Suspending the thumb with a counterpoise, the fracture is loosened and the length restored. The individual fragments are positioned using the raspatory, and, if necessary, the comminuted zones are filled with bone substitute to achieve a provisional reduction in position and...

カタログの10ページ目を開く
PRL - 11

Possible temporary fixation of individual fragments using guide wire, steel, D=1.6mm, L=150mm, TR w. Thrd. (35164-150) - check reduction using the fluoroscope. After anatomical reduction is achieved, the implant is chosen and, if required, its shape can be additionally adapted. First, fill the long hole with a D=2.7mm cortical screw (32271-XX) (suitable drills see page 4). Once more check the reduction and position of the plate using the fluoroscope. 11

カタログの11ページ目を開く
PRL - 12

Due to the longhole it is possible to adjust the plate position either distal or proximal. 12

カタログの12ページ目を開く
PRL - 13

For temporary fixation of the fragments there are 3 distal K-wire holes. 13

カタログの13ページ目を開く
PRL - 14

Following fill the shaft holes optionally with D=3.0mm cortical stabilization screws (37304-XX) or with D=2.7mm cortical screws (32271-XX) (suitable drills see page 4). 14

カタログの14ページ目を開く
PRL - 15

After re-checking the reduction 4 or more D=2.4mm stabilization screws (37241-XX) or D=3.0mm cancellous stabilization screws (37303-XX) should be used for the relevant fragments (suitable drills see page 4). Pay attention that the distal locking screws are placed as closely to the wrist surface as possible in order to take advantage of the hard subchondral bone. Two rows of screws are recommended to provide optimal support to the articular surface especially if only the D=2.4mm stabilization screw is used. Final checking using the fluoroscope. 15

カタログの15ページ目を開く

I.T.S. のすべてのカタログと技術パンフレット

  1. ufs

    1 ページ

  2. DHL

    2 ページ

  3. ITS

    2 ページ

  4. PHL

    24 ページ

  5. ACLS

    20 ページ

  6. CFN

    32 ページ

  7. OLS

    24 ページ

  8. PHLs

    20 ページ

  9. SR Sacral Rods

    20 ページ

  10. HCS

    24 ページ

  11. TOS Twist-Off Screw

    20 ページ

  12. TLS

    20 ページ

  13. PRS-RX

    32 ページ

  14. HLS

    20 ページ

  15. ES

    20 ページ

  16. SR

    20 ページ

  17. FL

    24 ページ

  18. CAS

    40 ページ

  19. FCN

    20 ページ

  20. HOL

    24 ページ

  21. FLS

    24 ページ

  22. PFL

    20 ページ

  23. DTL

    24 ページ

  24. HTO

    24 ページ

  25. PTL

    32 ページ

  26. DFL

    32 ページ

  27. SCL

    32 ページ

  28. SLS

    24 ページ

  29. CAL

    20 ページ

  30. DUL

    24 ページ

  31. CLS

    28 ページ

カタログアーカイブ

  1. SR Old

    20 ページ

  2. ES Old

    20 ページ

  3. CAS Old

    36 ページ

  4. CS

    16 ページ

  5. SN Old

    16 ページ

  6. FCN Old

    16 ページ

  7. DFL Old

    28 ページ

  8. FTN

    12 ページ

  9. PRS

    28 ページ

  10. UOL

    32 ページ

  11. SL

    16 ページ

  12. OHL

    24 ページ

  13. OL

    16 ページ

  14. DHL

    16 ページ

  15. PHL

    16 ページ

  16. CLS

    24 ページ