Implants trauma Straight Compression Locking Plate
カタログの1ページ目を開く
CAUTION: Federal Law (USA) restricts this device to sale by or on the order of a board certified physician. WARNING: If there is no sufficient bone healing, wrong or incomplete postoperative care, plate might break. All ITS plates are preformed anatomically as a matter of principle. If adjustment of the plate to the shape of the bone is required, this is possible by carefully bending gently in one direction once. Particular care is required when bending in the region of a plate hole, as deformation of the plate may lead to a failure of the locking mechanism. The plate must not be buckled or...
カタログの2ページ目を開く
1. Introduction P. 5 Preface P. 6 Screws P. 7 Properties P. 8 Indications & Contraindications P. 8 Time of operation 2. Surgical Technique P. 10 Drill Guide P. 10 Implantation P. 11 Compression 0 - 3.5mm P. 17 Compression 0 - 7mm P. 25 Postoperative treatment P. 25 Explantation P. 25 Summary 3. Information P. 27 Locking P. 27 Dotize® P. 28 Order list P. 29 Notes P. 30 Reconditioning Manual
カタログの3ページ目を開く
Preface The special feature of this implant is its compression hole. Due to an innovative technology it is possible to compress a fracture gap up to 7mm. A special design of the compression hole enables the use of a locking screw, which locks automatically after the full distance of compression. Indentations on the rear side of the plate for protection of the periosteum.
カタログの5ページ目を開く
37351-XX-N-N Cortical Screw, Locking, D=3.5mm, SH 61273-100 Spiral Drill, D=2.7mm, L=l00mm, AO Connector self-holding sleeve 61273-100 Spiral Drill, D=2.7mm, L=l00mm, AO Connector self-holding sleeve 35164-150 Guide wire, steel, D=l.6mm,
カタログの6ページ目を開く
Properties Properties of the implant: • Plate material: Titanium • Material of screws: TiAl6V4 ELI • Easier removal of the implant after the fracture has healed • Improved fatigue strength of the implant • Reduced risk of cold welding • Reduced risk of inflammation and allergy • Multi-directional locking • Indentations on the rear side of the plate for protection of the periosteum • Anatomical plate design • K-Wire holes for preliminary plate fixation • Fracture gap compression up to 7mm • Plate lengths: 4, 6, 8, 10-hole
カタログの7ページ目を開く
Indications, Contraindications & Time of operation Indications: • The plate should primary be used to reconstruct an anatomic situation • Corrective osteotomies The plate is not intended for shaft fractures of large bones such as femur and tibia Advanced osteoporosis In cases of skin and soft tissue problems Obesity Lack of patient compliance Time of operation: • Whitin the first hours after trauma • After swelling decreases (5-10 days)
カタログの8ページ目を開く
Surgical Technique
カタログの9ページ目を開く
Drill Guide Properties: • Two drill holes for free choice of using compression or static fixation • Special design of drill guide enables centric placement in the plate hole Hole close to handle for drilling a fixation screw Dark grey marked hole for drilling a compression screw Asymmetric centering assistance for easy placement in the plate hole Implantation • Prepare the patient with a general or regional anesthetic to the affected limb and use a pneumatic (tourniquet) for partial deprivation of the blood supply. • During the procedure, observe (using intra-operative x-ray fluoroscopy)...
カタログの10ページ目を開く
Compression 0 - 3.5mm For the compression up to 3.5mm alternatively the D=3.5mm cortical screw and the D=3.5mm locking cortical screw can be used at one side of the fracture to fixate the plate on the bone. Attach the drill guide, D=2.7mm (62216) in any plate hole. Use the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) to drill through the hole close to handle of the drill guide. In accordance with the measured length a D=3.5mm locking cortical screw (37351-XX-N) is placed.
カタログの11ページ目を開く
Use the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) to drill through the hole close to handle of the drill guide, D=2.7mm (62216) in the plate hole near the fracture. In accordance with the measured length a D=3.5mm cortical screw (32351-XX) is placed.
カタログの12ページ目を開く
On the right side of the fracture the D=3.5mm cortical screw and the D=3.5mm locking cortical screw are placed for the compression. Attach the drill guide (62216) in the opposite plate hole. Use the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) to drill through the dark gray marked hole of the drill guide, D=2.7mm (62216). In accordance with the measured length a D=3.5mm cortical screw (32351-XX) is placed half way down as it is used as a guide screw during the compression.
カタログの13ページ目を開く
Attach the drill guide (62216) in the adjacent plate hole. Use the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) to drill through the dark gray marked hole of the drill guide, D=2.7mm (62216). In accordance with the measured length a D=3.5mm locking cortical screw (37351-XX-N) is placed half way down.
カタログの14ページ目を開く
During screwing in the D=3.5mm locking cortical screw (37351-XX-N) a compression is exerted to the fracture gap (see pictures below).
カタログの15ページ目を開く
Afterwards attach the drill guide, D=2.7mm (62216) to the furthest left plate hole. Use the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) to drill through the hole close to handle of the drill guide. In accordance with the measured length a D=3.5mm locking cortical screw (37351-XX-N) is placed. Attach the drill guide, D=2.7mm (62216) to the furthest right plate hole. Use the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) to drill through the hole close to handle of the drill guide. In accordance with the measured length a D=3.5mm locking cortical screw (37351-XX-N) is...
カタログの16ページ目を開く
Compression 0 - 7mm For the compression up to 7mm the D=3.5mm locking cortical screws are used at both sides of the fracture for compression. The D=3.5mm cortical screws and the D=3.5mm locking cortical screws in both plate holes farthest to the fracture are for fixation. Attach the drill guide, D=2.7mm (62216) in any plate hole. Use the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) to drill through the dark gray marked hole of the drill guide. In accordance with the measured length a D=3.5mm locking cortical screw (37351-XX-N) is placed half way down (screw head may not have...
カタログの17ページ目を開くI.T.S. のすべてのカタログと技術パンフレット
-
ufs
1 ページ
-
DHL
2 ページ
-
ITS
2 ページ
-
PHL
24 ページ
-
ACLS
20 ページ
-
CFN
32 ページ
-
OLS
24 ページ
-
PHLs
20 ページ
-
SR Sacral Rods
20 ページ
-
HCS
24 ページ
-
TOS Twist-Off Screw
20 ページ
-
TLS
20 ページ
-
PRS-RX
32 ページ
-
HLS
20 ページ
-
ES
20 ページ
-
SR
20 ページ
-
FL
24 ページ
-
CAS
40 ページ
-
FCN
20 ページ
-
HOL
24 ページ
-
FLS
24 ページ
-
PFL
20 ページ
-
DTL
24 ページ
-
HTO
24 ページ
-
PTL
32 ページ
-
DFL
32 ページ
-
SLS
24 ページ
-
CAL
20 ページ
-
DUL
24 ページ
-
CLS
28 ページ