カタログの抜粋

SACRAL RODS emergency team for broken bones®
カタログの1ページ目を開く
• aterial: TiAL6V4 ELI M • asier removal of implant after fracture has healed E • mproved fatigue strength of implant I • educed risk of cold bonding R • educed risk of inflammation and allergy R • Threaded rods with washers and locknuts for ilio-iliac compression osteosynthesis • Stepped thread to increase fatigue strength • Washer: wedge-shaped, ribbed, anatomically contoured • Stable guiding instrument for simple and safe positioning of threaded rods • Socket spanner system with AO standard adapter for fast and simple fastening of nuts SACRAL RODS emergency team for broken bones®...
カタログの2ページ目を開く
Indications • Dorsal stabilisation on the posterior pelvic ring for unstable pelvic ring injures type C/AO, especially in the case of: • Unstable sacral fractures in all three zones • Osteo-ligament instabilities of the sacro-iliac joint SACRAL RODS emergency team for broken bones® Sacral Rods
カタログの4ページ目を開く
Sacral Rods The operative management of pelvic ring disruptions has always represented a challenge to the treating surgeon. The sufficient stabilisation of such an injury requires both a profound knowledge of the anatomy and biomechanics of the pelvis and an understanding of the mechanism of fracture. The chosen technique of a posterior stabilisation depends on the one hand on the kind of fracture, and on the other hand on the personal experience of the individual operator. Threaded rods as fixators of posterior pelvic ring instability have been well known and well proven for a long time,...
カタログの5ページ目を開く
Description of Surgery Ventral stabilisation As a rule, a ventral stabilisation is carried out as the first intervention since a secondary reposition of the anterior pelvic ring in the case of an already reduced dorsal fracture could lead to an uncontrolled compression of the plexus sacralis. SACRAL RODS emergency team for broken bones® Dorsal stabilisation Dorsal stabilisation is carried out in the prone position of the patient, usually under full anaesthesia and in the same session. A curved skin incision is made on both sides lateral to the sacro-iliac joint, from the spina iliaca...
カタログの6ページ目を開く
Preparation Spina iliaca post. superior Preparation of the subcutaneous fat tissue and carried down to the fascia of the glutaeus maximus muscle. Loosen the musculature from the outer surface of the dorsal os ileum. Linea glutea posterior Reposition A possibly necessary reposition of half of the pelvis is carried out by means of a Schanz screw attached to the crista iliaca. Deployment of the guiding instrument and checking by means of image converter. Guiding instrument: It is strongly advised not to use the enclosed guiding device for reducing bone fragments since it could be damaged in...
カタログの7ページ目を開く
Spina iliaca post. superior The linea glutea posterior acts as the reference point. The guiding instrument is positioned on a considered line between the origin of the linea glutaea posterior on the iliac crest and the spina iliaca inferior; the drill hole will then lie some 0.5 cm higher. The caudal screw is attached first, and the point of entry is to be chosen such that the rod is at a tangent to the crista centralis of the os sacrum or even perforates it, but at least comes to rest behind the lamina dorsalis of the sacrum. connecting line Linea glutea posterior – spina iliaca post....
カタログの8ページ目を開く
The asymmetric washer, nut and locknut are attached (this is done the most simply by continuing to turn the rod with the drill). Both nuts must be definitively tightened. The drill chuck is released, the guiding instrument removed, and the washer is attached as are, successively, both nuts on the second side using the special socket spanner and the soft-part protector. Wedge shaped spacers: Please note the exact anatomical position shown here to arrive at the best result. SACRAL RODS
カタログの9ページ目を開く
SACRAL RODS emergency team for broken bones®
カタログの10ページ目を開く
socket spanner with soft-part protection The first nut is tightened until the desired compression of the fracture area is reached (care must be taken not to use excessive compression with transforaminal fractures of the sacrum.) Both nuts must be tightened. Remove the excess end using the bolt cutters. The same procedure is undertaken with the second screw, which is to be positioned some 2 cm cranially to the first screw. adapter for socket spanner Check Final check using image converter or X-ray, redon drainage, subsequent closure of the wound. SACRAL RODS Postoperative Treatment Dependent...
カタログの11ページ目を開く
Implants & Instruments SACRAL RODS emergency team for broken bones® Order No. 5 Guiding Instrument, 5 Parts, Sacral Rod 8 Tissue Protection Sleeve 12 AO Screw Adaptor, Socket Wrench 13 Bolt Cutter, Pelvis Screws, Sacral Rod 14 Sterilization Tray, Sacral Rods
カタログの12ページ目を開く
SACRAL RODS Implants Order No. 1 Sacral Rod, Threaded 2 Washer, Wedge-Shaped, Ribbed
カタログの13ページ目を開く
Chemical process - anodization in a strong alkaline solution * Type III anodization Dotize Type II anodization Different colors Film become an interstitial part of the titanium Implant surface remains sensitive to: Chipping Peeling Discoloration No visible cosmetical effect Anodization Type II leads to following benefits * • • • • • • • • Oxygen and silicon absorbing conversion layer Decrease in protein adsorption Closing of micro pores and micro cracks Reduced risk of inflammation and allergy Hardened titanium surface Reduced tendency of cold welding of titanium implants Increased fatigue...
カタログの14ページ目を開く
Sterilization Guidelines The following remarks should serve as a guideline in the sterilization of medical products. IMPORTANT INDICATIONS FOR DOCTORS AND OPERATING THEATRE PERSONNEL This instruction leaflet refers to all supplied nonsterile implants and all reusable instruments from I.T.S. GmbH. Detailed information for the identification of the product (such as system classification, cat. no.) can be found in the product identification code and/ or on the package label. Make sure that you are familiar with the possibilities of application, combinability and correct handling of the...
カタログの16ページ目を開くI.T.S. のすべてのカタログと技術パンフレット
-
ufs
1 ページ
-
DHL
2 ページ
-
ITS
2 ページ
-
PHL
24 ページ
-
ACLS
20 ページ
-
CFN
32 ページ
-
OLS
24 ページ
-
PHLs
20 ページ
-
SR Sacral Rods
20 ページ
-
HCS
24 ページ
-
TOS Twist-Off Screw
20 ページ
-
TLS
20 ページ
-
PRS-RX
32 ページ
-
HLS
20 ページ
-
ES
20 ページ
-
SR
20 ページ
-
FL
24 ページ
-
CAS
40 ページ
-
FCN
20 ページ
-
HOL
24 ページ
-
FLS
24 ページ
-
PFL
20 ページ
-
DTL
24 ページ
-
HTO
24 ページ
-
PTL
32 ページ
-
DFL
32 ページ
-
SCL
32 ページ
-
SLS
24 ページ
-
CAL
20 ページ
-
DUL
24 ページ
-
CLS
28 ページ