カタログの抜粋
Product Configuration Item Description Rotational speed settings: 0.75s, 1s, 1.5s Tilt function can produce optimal image by alignment of region of interest during head and lumbar spine scans minimizing the dose and extending the X-ray tube life. 3D Laser Alignment System Internal line laser and external cross line laser make 3D alignment accurate.Single button positioning makes it convenient to operate. Wide-Angle Gantry Display Internal line laser and external cross line laser make 3D alignment accurate.Single button positioning makes it convenient to operate. Smart Breathing Guide System...
カタログの10ページ目を開くX-ray Tube and High Voltage Generator X-ray Tube Type: Dual Metal X-Ray Tube Metal Enclosure + Liquid Metal Bearing) ( Higher performance with continuous scan capability of >200 patient exams per day Doubling the lifetime of other type X-ray tubes saving significant replacement cost High-end configuration matching X-ray tubes used solely for cardiac CT systems X-ray Tube Enclosure Type: Metal Reliable: Metal has greater strength withstanding higher centrifugal force under high-speed rotation compared with glass. Durable: Arcing is avoided with no change to field strength with ionization....
カタログの11ページ目を開くPatient Table Horizontal Movement Range: 1700mm Maximum Weight on Table: 205kg Large Vertical Movement Range Make it convenient for the elderly, children and handicap patients Smart Patient Table Release Switches Table Pad Pad with wings covering table effectively preventing pinching and liquid spilling Operator Console Display Monitor Console & Recon Computer Fast image reconstruction via recon computer equipped with GPU acceleration Keyboard and Mouse Control Box Support patient table control, scan exposure and intercom in console room Single touch emergency stop button Single key stroke...
カタログの12ページ目を開くClinical Application Software Automatic Bolus Tracking Automatically trigger CT scan when contrast media reaches the threshold level with real-time monitoring. Pediatric Protocols Protocols optimized to meet clinical needs of children with low dose exposure Smart mA Modulation Technique - AccumA Automatic adjustment of scan parameter based on patient’ body and target scan area optimizing radias tion dose without compromise in image quality Three-Domain Iterative Algorithm - ZTV Breaking the projection data and image data limitation by conventional iterative algorithms, ZTV algorithm...
カタログの13ページ目を開くJiangsu Aegean Technologyのすべてのカタログと技術パンフレット
-
SZYSL-002 Glucometer
2 ページ
-
Head Immobilizer
2 ページ
-
Doctor Sool
2 ページ
-
AG-LJ02 Trash Can
2 ページ
-
AG-GZ01 Soap Box
2 ページ
-
AG-2B7D Spine Board
2 ページ
-
Aegea Catalog
32 ページ