グループ: Danaher

カタログの抜粋

Leica HCS A Amplify the Power of Imaging High Content Screening Automation
カタログの1ページ目を開く
• Amplify the power of confocal imaging with Leica HCS A • Maximum flexibility for universal applications • Easy-to-use automation provides efficient high content screening • Powerful hardware for high resolution imaging and maximum content 2 Leica Design by Christophe
カタログの2ページ目を開く
High Content Screening (HCS) allows researchers to quickly change from descriptive to quantitative fluorescence imaging during an experiment. High resolution imaging automation therefore answers complex questions in shorter time. It simplifies research work and efficiently reveals relationships within and between cells and organisms. Leica Microsystems offers a set of innovative tools to convert your high resolution confocal microscope into a high content imaging device. Leica HCS A High Content Screening Automation Leica Microsystems provides a wide range of true spectral confocal imaging...
カタログの3ページ目を開く
Features • High resolution imaging • Time saving automation • Open architecture • Platform independent results • OME data formats • Perfect integration Modern research is a continuous cycle of experiment design, setup imaging, data handling, and analysis to discover live's processes and answer questions. Power of Imaging Result Content Analysis Data Processing Sample Preparation Automated Leica High Content Screening High resolution imaging techniques answer many questions in modern life science. For high content screening, automation is essential to efficiently achieve results. Intelligent...
カタログの4ページ目を開く
Sample eparation Leica High Content Screening Automation Data Management Content Analysis Research Result a Rat brain slice, small neuron network layer 5. Interneurons (Alexa 594, red) and Pyramidal Cell Oregon (Bapta 1, calcium sensitive, green). Courtesy of Dr. Thomas Nevian, Institute of Physiology, University of Bern, Switzerland. b Danio rerio – Zebrafish – Nuclear and Acetylated α-Tubulin staining of 6 days flh:eGFP Zebrafish larvae Nuclei (Hoechst, blue), acetylated tubulin (red) and neurons (GFP, green). Courtesy of ICI Imaging Centre IGBMC, Illkirch, France. Choose the adequate...
カタログの5ページ目を開く
Many companies offer dedicated imaging routines for dedicated assays only. Leica Microsystems provides standard solutions for routine experiments plus maximum flexibility to freely adapt imaging. Features • Smart user interfaces • Workflow oriented wizards • Predefined templates • Easy adjustment • Quick start Easy-to-use AutomationWe Keep It Simple! Wizards guide the user through an experiment in a streamlined way. Design follows function - benefit from clear user interfaces, ensuring fast training and the highest productivity. Predefined Scanning Templates Place the specimen carrier on...
カタログの6ページ目を開く
Mouse diaphragm muscle stained against neuro-filament 150. Mosaic: xyz: 5 x 5 x 101 images Green: Alexa Fluor 488-secondary antibody and acetylcholine receptors (Red: Alexa Fluor 647-alpha-bungarotoxin). Courtesy of Dr. R. Rudolf, Cellular Signaling in Skeletal Muscle, Karlsruhe Institute of Technology, Germany.
カタログの7ページ目を開く
Automated High Content Screening Simplifies Da LAS AF software simplifies routines. Leica Microsystems’ goal is to make daily work as easy as possible so researchers can concentrate on the results, not on the imaging process. We Keep it Simple! LAS AF MATRIX Mosaic Fine details as well as an overview are important when evaluating experimental results. Today, simple routine tasks, such as stitching of individual images are challenging. Leica HCS A provides entirely new designed mosaic algorithms for excellent results at the push of a button. Leica LAS AF MATRIX Mosaic generates large high...
カタログの8ページ目を開く
Daily Routines High Resolution Single Image High Content Mosaic Fast Multiwell Plate Screening High Content Information
カタログの9ページ目を開く
Gain Flexibility Flexible scanning conditions, even on the smallest scan field level, match a full variety of experiments. Adjustable Scanning Templates No need to be a programmer – new scanning templates can be designed at micron scale to easily fit chamber slides, multiwell plates or simple spotter arrays. Once defined, the templates are ready to use for all applications and can even be conveniently shared between laboratories or communities. Imaging without Limits – MultiJob and MultiPositioning Feel free to combine a variety of individual scan jobs for any area of interest of the specimen....
カタログの10ページ目を開く
Autofocus Routines Five autofocus algorithms are available, optimized for different setups. The suitable routine is selected from a pull-down menu. After the initial scan, the software automatically creates a focus map with true sample topology. This map is used for fast, accurate z-positioning during the scan. According to the size and planarity of the samples, the optimal number and positions of the autofocus points can be freely defined. Z-Drift Compensation Live specimens can grow in long-time measurements, changing the z-position of interest. Microscope conditions can change due to...
カタログの11ページ目を開く
Automated High Content Screening for Quant Detect Rare Events On-the-Fly! LAS AF MATRIX Developer Suite Highly complex assay designs are now possible with LAS AF MATRIX Developer Suite. The Mitocheck project (1), conducted at the EMBL in Heidelberg, is an excellent example of comprehensive and flexible automation: The self-acting process automates mitosis identification. High Content Screening with Fast Pre-Scan Pre-Scan – Object Identification At first, a fast, low resolution pre-scan of sample plates is routinely performed to identify the events of interest (1). After each scan, OME-image...
カタログの12ページ目を開く
h Interactive System Control: Fully Automated Mitosis Acquisition High Content Scan Feedback Automation Image Analysis embl ijjjjjjjl 1. Pro-Scan 2. Analysis 3. Classification Segmentation Feature Extractor Object Object Selection
カタログの13ページ目を開く
The Perfect MatchData Interfaces Open architecture for truly platform independent information exchange in an interactive environment - this is the goal attained by the new Leica HCS A data model. Experiment Meta Data Administration Experiment IDs, description, and meta data can be entered manually or by barcode. Additional experiment information can be added to the existing XML meta data file by external programming to provide comprehensive result data sets. Platform Independent Results Distribution Leica HCS A imaging formats can be used platform independent on Apple MAC™ OS, Microsoft...
カタログの14ページ目を開くLeica Microsystems/ライカのすべてのカタログと技術パンフレット
-
M844 F40/F20
16 ページ
-
EnFocus
12 ページ
-
M822 F40 / F20
12 ページ
-
M320 for ENT
12 ページ
-
ARveo 8
16 ページ
-
M320 Dental Brochure
12 ページ
-
Emspira 3
4 ページ
-
Exalta
2 ページ
-
FLEXACAM C1
4 ページ
-
EM KMR3
8 ページ
-
EM UC7
16 ページ
-
EM TRIM2
8 ページ
-
EM RAPID
8 ページ
-
EM ICE
12 ページ
-
EM TXP
10 ページ
-
EM RES102
12 ページ
-
EM TIC 3X
16 ページ
-
TL4000 BFDF
16 ページ
-
F12 I floor stand
6 ページ
-
XL Stand
4 ページ
-
KL300 LED
8 ページ
-
LED1000
16 ページ
-
LED3000 BLI
20 ページ
-
LED5000 NVI
20 ページ
-
LED3000 NVI
20 ページ
-
LED3000 DI
20 ページ
-
LED5000 HDI
20 ページ
-
LED5000 CXI
20 ページ
-
LED2500
8 ページ
-
LED5000 MCI
20 ページ
-
LED3000 MCI
20 ページ
-
LED5000 SLI
20 ページ
-
LED3000 SLI
20 ページ
-
LED2000
8 ページ
-
LED5000 RL
20 ページ
-
LED3000 RL
20 ページ
-
MZ10 F
4 ページ
-
M165 FC
16 ページ
-
M205 FCA, M205 FA
16 ページ
-
A60 F, A60 S
16 ページ
-
M50, M60, M80
12 ページ
-
DVM6
16 ページ
-
TCS SPE
20 ページ
-
DFC450 C
6 ページ
-
DFC295
6 ページ
-
MC170 HD
6 ページ
-
DFC3000 G
6 ページ
-
DMC4500
4 ページ
-
ICC50 W, ICC50 E
6 ページ
-
DFC9000
2 ページ
-
IC90 E
6 ページ
-
DMC6200
8 ページ
-
DMC5400
8 ページ
-
SFL7000
4 ページ
-
EL6000
4 ページ
-
SFL100
4 ページ
-
SFL4000
4 ページ
-
DMi8 S Platform
2 ページ
-
DMi8 M / C / A
12 ページ
-
DM IL LED
12 ページ
-
DMi1
6 ページ
-
DM3 XL
7 ページ
-
FS M
4 ページ
-
FS C
4 ページ
-
FS CB
4 ページ
-
DM3000, DM3000 LED
16 ページ
-
DM750 M
12 ページ
-
DM750
12 ページ
-
DM500
12 ページ
-
DM300
8 ページ
-
DM12000 M
8 ページ
-
DM8000 M
8 ページ
-
DM1750 M
12 ページ
-
DM4 M, DM6 M
12 ページ
-
DM4 P, DM2700 P, DM750 P
12 ページ
-
DM2000, DM2000 LED
16 ページ
-
DM1000
16 ページ
-
DCM8
16 ページ
-
DM1000 LED
16 ページ
-
DM2500
16 ページ
-
DM4 B & DM6 B
16 ページ
-
DM6 M LIBS
2 ページ
-
S9 Series
12 ページ
-
Z6 APO
16 ページ
-
Z16 APO
16 ページ
-
M620 F20
8 ページ
-
M220 F12
8 ページ
-
Proveo 8
16 ページ
-
M525 F20
12 ページ
-
PROvido
8 ページ
-
Leica M530 OHX
16 ページ
-
Leica TCS SP8 STED 3X
24 ページ
-
Leica TCS SP8 Objective
24 ページ
-
Leica AOBS
16 ページ
-
Leica DMC2900
6 ページ
-
Leica DMshare
2 ページ
-
Leica_SL801-Flyer
2 ページ
-
DM2700 M
12 ページ
-
Leica_SR_GSD-Brochure
10 ページ
-
Leica_AF6000-Brochure
16 ページ
-
Leica TCS SP8-Flyer
2 ページ
-
Leica TCS SP8-Brochure
40 ページ