
グループ: MP

カタログの抜粋

Malvern laser diffraction technology The smartest way to measure particle size
カタログの1ページ目を開く
Class-leading performance with added intelligence Mastersizer 3000+ builds on the trusted and marketleading Malvern Panalytical platform to define the next evolutionary step in particle size analysis. The plus embodies groundbreaking easy-to-use capabilities that boost your confidence during your work and in your results. Smart Manager harnesses the power of IoT to ensure instrument health and makes the Mastersizer 3000+ more connected than ever. Data Quality Guidance gives real-time feedback and troubleshooting advice, whereas SOP Architect, fueled by automated data analysis algorithms,...
カタログの2ページ目を開く
A system built with brilliance Mastersizer Auto-Lab Quality data you can rely on Saving valuable time The Mastersizer 3000+ uses laser diffraction to measure particle size distributions from 10 nm to 3.5 mm. Its optical core design delivers measurements in as little as a few seconds, enabling high sample throughput. The Mastersizer Auto-Lab measures up to 42 samples and you can utilize the same great measurement performance and flexibility as the Mastersizer whilst minimizing manual operating time. Freeing your team to be where they will add most value to your business. For this and more...
カタログの3ページ目を開く
Measurement Manager Method development made simple Being able to view how particle-size results change with dispersion conditions is essential to rapid method development within ISO and USP guidelines. With the Measurement Manager window, users can observe, control, and optimize measurement conditions in real time, making the method development process as efficient and straightforward as possible. Mastersizer Xplorer Guidance through every measurement stage In today’s busy laboratory environments, with more and more demands on instruments and users, software that is intuitive and easy to...
カタログの4ページ目を開く
Data Quality Guidance Making good data excellent Method matters Any scientist will know that, to ensure robust results, it’s good experimental practice to assess measurement quality. The Data Quality Guidance feature within the Mastersizer Xplorer software supports this, providing an immediate assessment of your data quality. This means you can spend less time troubleshooting and more time working with results you are confident in. Without support, the method development process can be challenging: there are many experiments to perform and many decisions to make when reviewing data. SOP...
カタログの5ページ目を開く
Adaptive Diffraction and Size Sure Smart Manager Deeper analysis for smarter insights Daily support to optimize uptime In real-world applications, outside influences can make your laser diffraction measurements more difficult. Contaminants, bubbles, and dust can all interfere and contribute to the measured scattering signal, resulting in misleading particle size distributions. Smart Manager is a cloud based background service that performs a regular ‘health check’ on several of Malvern Panalytical’s Instruments. The Mastersizer 3000+ has the ability to connect to this cloud platform,...
カタログの6ページ目を開く
Main system specifications MALVERN LASER DIFFRACTION TECHNOLOGY The flexibility to suit your application and budget Particle size distribution Suspensions, emulsions, dry powders General Principle Laser light scattering Data acquisition rate Typical measurement time • Measures particles ranging from 0.1 – 1,000 µm Blue light source Lens arrangement Reverse Fourier (convergent beam) Reverse Fourier (convergent beam) Effective focal length Every application area – and budget! – is different. That’s why the Mastersizer 3000+ range contains options that cater to multiple MASTERSIZER3000+ needs....
カタログの7ページ目を開く
Mastersizer 3000+ sample dispersion overview Sample dispersion is controlled by a range of wet and dry dispersion units. These ensure the particles are delivered to the measurement area of the optical bench at the correct concentration and in a suitable, stable state of dispersion to make accurate and reliable particle size measurements. Aero S dry powder disperser Hydro - Rapid and effective wet dispersion accessories State-of-the art dry powder dispersion The Aero S dry powder disperser has been developed using state-of-theart powder dispersion understanding. Modular in design, it is...
カタログの8ページ目を開く
Aero M dry powder disperser Bulk dry powder dispersion Large volume wet sample dispersion Intended for applications where sample availability is not an issue, the Hydro LV is ideal for measuring larger particles and broad size distributions, which demand larger sample volumes to ensure representative measurement. The Aero M is an entry-level dry powder disperser for the Mastersizer 3000+ Lab and Pro, enabling particle size distribution measurements to be made for bulk dry powder samples. Its design achieves robust particle size measurements in industrial applications and also ensures it is...
カタログの9ページ目を開く
Medium volume automated dispersion unit Flexible volume wet dispersion The Hydro EV has a unique dip-in centrifugal pump and stirrer design that achieves full and rapid dispersion in standard laboratory beakers, allowing close matching of the dispersant volume to the application requirements. Following measurement, the dispersion head can be raised out of the beaker, enabling quick cleaning and sample recovery. The Hydro MV is medium volume unit for the controlled, automated wet dispersion of samples for particle size analysis. Designed for applications that require smaller sample sizes,...
カタログの10ページ目を開く
Small volume wet sample dispersion Manual entry level wet dispersion unit The Hydro SV is a simple, cost effective dispersion unit designed to enable particle size analysis using small volumes of sample and dispersant. It is particularly useful where the amount of sample available for analysis is very limited, or where there are significant environmental or health and safety issues associated with the use of the dispersant required to measure the sample. The Hydro SM is a cost effective wet sample dispersion unit designed for measuring samples in non-aqueous dispersants where solvent usage...
カタログの11ページ目を開くMalvern Panalyticalのすべてのカタログと技術パンフレット
-
NanoSight Pro
5 ページ
-
Zetasizer Advance
5 ページ
-
creoptix
12 ページ
-
omnisec
9 ページ
-
spectrometre
2 ページ
-
superQ
5 ページ
-
Zetasizer Advance
5 ページ
-
Aeris Cement Edition
5 ページ
-
Claisse LeDoser
6 ページ
-
EMPYREAN ALPHA-1
3 ページ
-
MicroCal DSC range
7 ページ
-
Empyrean
5 ページ
-
Epsilon 1
7 ページ
-
Claisse Eagon 2
4 ページ
-
Epsilon 4
7 ページ
-
Xflow
8 ページ
-
Zetasizer Pro and Ultra
20 ページ
-
2830 ZT
12 ページ
-
MicroCal ITC range
16 ページ
-
Spraytec
9 ページ
-
Aero M
2 ページ
-
MICROCAL PEAQ-DSC Range
12 ページ
-
Viscotek UV
2 ページ