The 3-HEAD SPECT imager family for clinical and clinical/preclinical research SPECT, SPECT/CT and SPECT/CT/PET The first and only clinical Triple-Detector SPECT/CT system with Parallel and Multi-PinHole Collimation with PET-like Imaging and Workflow

カタログの1ページ目を開く
ANTR_1118_web.pdf - 2

Introduction of AnyScan® TRIO Triple-Detector SPECT-Based Imager Family Mediso is at the frontier of the development of SPECT & PET systems. This is based upon more than 50 years of medical imaging experience and a century of company tradition within the precision engineering industry. Mediso is the only vendor in the world to design, develop and manufacture both pre-clinical research and clinical hybrid molecular imaging systems. The AnyScan® TRIO SPECT/CT Systems originate from this unique synergy, as the new breakthrough in hybrid molecular imaging. Triple detector SPECT imaging systems...

カタログの2ページ目を開く
ANTR_1118_web.pdf - 3

Mediso also offers Clinical Edition of this triple detector AnyScan® TRIO SPECT/CT. This system is designed with the clinical practice in mind. Increased resolution and significant reduction in imaging time result in greater patient comfort and compliance. Enhanced imaging protocols and software advances result in more precise diagnostics and an improved clinical decision workflow, thus higher daily patient throughput. The main features of Clinical Edition are: ------ Clinical Edition UHP detectors, with 60 PMTs each, or Xtreme EditionTM with 94 PMTs each Extended FOV and sensitivity...

カタログの3ページ目を開く
ANTR_1118_web.pdf - 4

The AnyScan® Platform Made for NM Department IMAGING TABLE AnyScan® TRIO inherited AnyScan®’s unique flexibility in modularity ----- SPECT/CT and PET/CT imaging in ONE room All protocols are completed in less than 20 minutes Flexible system combinations due to “building block” SPECT, CT and PET system Multiple upgrade paths: -- Add-on upgrade from single unit to triple modality which covers all NM diagnostic procedures with a single device in a single room -- Splitting upgrade from triple modality to more units in order to achieve a higher throughput of the NM department -- Made for NM...

カタログの4ページ目を開く
ANTR_1118_web.pdf - 5

AnyScan® TRIO SPECT/CT replaces 2 conventional dual head systems The AnyScan® TRIO with the novel LEHRHS parallel collimator set has the performance of 2 conventional dual head SPECT-CT systems. -- Acquisition time on conventional dual head camera is 20 minutes. -- Acquisition time on triple head camera is 10 minutes. The extra detector and the addition of the novel LEHRHS collimators reduces the acquisition time by 50% compared to conventional dual head SPECT/CT systems. As the below picture shows acquisition time shortens significantly by applying LEHRHS parallel hole collimator or...

カタログの5ページ目を開く
ANTR_1118_web.pdf - 6

AnyScan® TRIO SPECT/CT System Features Performance in all aspects Mediso has invested more than a decade into the research and development of SPECT detector technologies and multipinhole collimation. As a result the multi-detector and multipinhole collimation are today the gold standard in Mediso’s quantitative pre-clinical SPECT/CT systems (nanoScan®SPECT/CT). Now the very same technologies became the essence of AnyScan® TRIO. On demand application specific apertures Brain apertures Cardiology apertures Mediso’s experience and expertise expertise in the development of both preclinical and...

カタログの6ページ目を開く
ANTR_1118_web.pdf - 7

AnyScan® TRIO SPECT/CT System Benefits The comparison below shows the benefits of AnyScan® TRIO in SPECT imaging versus the conventional dual detector (NaI or CZT), parallel-hole collimated SPECT/CT systems. Best System Average Sensitivity up 6x higher with MPH aperture for Cardiology 5x higher with MPH aperture for Neurology 2x higher with LEHRHS parallel hole collimator Best System Resolution 2x system resolution thanks to the triple head system and the MPH technology Best Contrast-to-Noise Ratio 2X Contrast to Noise Ratio (CNR) with the new Monte Carlo-based Tera-Tomo™ 3D SPECT - Q/MPH...

カタログの7ページ目を開く
ANTR_1118_web.pdf - 8

Different Applications of AnyScan® TRIO’s Unified Platform 1. Routine Clinical Application The Clinical Application Package of AnyScan® TRIO includes the Clinical Edition of AnyScan® TRIO - meaning Clinical Edition UHP detectors, with 60 photomultiplier tubes each - and parallel-hole collimators. The Tera-Tomo™ 3D SPECT - Q reconstruction package is available as an option. The AnyScan® TRIO’s unified platform is capable of performing both dual and triple head mode acquisitions. Dual detector mode allows the user to cross validate their original protocols, coming from the conventional...

カタログの8ページ目を開く
ANTR_1118_web.pdf - 9

Performance and Optimized Workflow The TRIO system features three best-in-class detectors with Ultra-high Resolution and Performance Non-Anger detection logics Extra-large maximum FOV: 545 x 400 mm Photomultipliers: 123 / 94 / 60 pcs/detector Typical intrinsic FWHM resolution: 2.5 / 2.8 / 3.2 mm Full Energy range Clinical Imaging from 40 keV to 960 KeV Linear maximal count rate: >700 000 cps Optimized Workflow and ultra-fast Acquisition Time Clinical workflow is dramatically improved by the AnyScan® TRIO through the reduction of clinical decision making steps. A common problem during Whole...

カタログの9ページ目を開く
ANTR_1118_web.pdf - 10

Cutting Edge Clinical and Research Imaging After a decade of research and development of SPECT detector and Multi PinHole collimation technology on the preclinical field, Mediso now integrated this knowledge into a unique human SPECT/CT System, the AnyScan® TRIO. Research and Clinical Editions are available for pre-clinical and clinical research and cutting edge clinical practice respectively. A wide range of research applications are now possible by the introduction of the AnyScan® TRIO, such as Biomarkers, Receptor binding in Neurology, Stem Cell Research, Drug Discovery and Ligand...

カタログの10ページ目を開く
ANTR_1118_web.pdf - 11

Clinical Routine Imaging Whole Body SPECT Whole Body SPECT replaces conventional planar Whole Body Scans. After the system generates the 3D SPECT images, planar views are created for navigation, reducing overall examination time. Optimized Continuous Workflow This automated reconstruction protocol means that no resetting of the patient scan parameters, and no extra clinical decisions by the physician are needed during the scan workflow resulting reduced imaging time and workload. Continuous SPECT Compared to conventional step and shoot mode Continuous mode provides shorter acquisition time....

カタログの11ページ目を開く