MELAtronic®EN 15 EN · 17 EN · 23 EN The European Standard EN 13060 divides tabletop autoclaves into the classes B, S and N. Class B is the class with the highest requirements, such as are required on clinic autoclaves. Class S devices have less performance capability and for instance cannot be used for complicated hollow instruments or multiple wrapping. Class N are autoclaves that can be employed for the sterilization of solid instruments. MELAtronic ® EN autoclaves have two „N“ and two „S“ programs. Quality - made in Germany Which autoclave, according to the European Standard, is appropriate for your medical or dental practice? According to national hygiene requirements the physician or dentist is obliged to use risk assessment methods to dene which types of instruments and packaging are to be used in the medical or dental practice. In other words, it be must be decided whether B, S or N should be employed. Bacteriological expert opinions and thermoelectric measurements of the sterilizing effect of the MELAtronic ® EN autoclaves for wrapped instruments have demonstrated that both „S” programs can sterilize small quantities of wrapped solid instruments. MELAtronic ® EN autoclaves are for the sterilization of solid instruments according to EN 13060. Evidence Based Sterilization
カタログの1ページ目を開く
MELAtronic® EN · Available in 3 sizes Fractionated gravity system The autoclaves of the MELAtronic ® EN model series work with a fractionated, microprocessor-controlled gravity system, which rapidly reduces the content of remaining air and effectively attains saturated steam. MELAtronic ®15 EN Temperature exactness by electronic control To ensure a successful sterilization, the MELAtronic ® EN autoclaves have two redundant temperature sensors and one precision sensor for pressure. During the program, the high graded electronic acquires data on temperature, pressure, and time. The autoclaves...
カタログの2ページ目を開く
· According european standard 13060 MELAprint ®42 - log printer Different national guidelines often demand that the operator documents the instrument sterilization. The documentation of the program cycles for the autoclaves of the MELAtronic ® EN series is possible with the log printer MELAprint ®42 over the standard built-in interface (RS 232) for the following data records: · Selected program · Date, time, batch number · Actual values of time, pressure and temperature · Conrmation of the successfully completed program · Inadmissible deviations, in case they occurred. MELAash...
カタログの3ページ目を開く
Operational time (without drying) Warm start 1 kg instruments 17-21 min Cold start 2kg Instruments 22 - 29 min Operational time (without drying) Warm start 1 kg instruments 37 - 47 min Cold start 2kg instruments 44 - 59 min Operational time (without drying) Warm start 1 kg Instruments 21 - 30 min Cold start 2kg Instruments 27 - 38 min Operational time (without drying) Warm start 1 kg instruments 36 - 45 min Cold start 2kg instruments 42 - 53 min Technical data Good drying results can be achieved with the chamber Is preheated to a pre-defined tem- perature by activating the "preheating"...
カタログの4ページ目を開くMELAGのすべてのカタログと技術パンフレット
-
MELAseal
9 ページ
-
Pro-Line
7 ページ
-
MELAnet Box
5 ページ
-
MELAdoc
5 ページ
-
MELAstore
3 ページ
-
MELAtherm®10
9 ページ
-
MELAcontrol
5 ページ
-
Careclave Prospekt
9 ページ
-
System Solution dental
12 ページ
-
melatronic 23
4 ページ
-
MELAdem®
8 ページ
-
MELAquick 12+ p
6 ページ
-
MELAtronic EN+
4 ページ
-
CLINICLAVE 45
4 ページ
-
Sterilizer 205
2 ページ
-
Sterilizer 75
2 ページ
-
MELAseal 100+
4 ページ
-
MELAdem 40
2 ページ
-
MELAcontrol Pro
6 ページ
-
MELAtherm 10
12 ページ
-
EUROKLAV +
12 ページ
-
S-Class
12 ページ
-
Profi-Class
12 ページ
-
MELAdest® 65
2 ページ
-
MELAdem®40
2 ページ
-
MELAtronic®15EN+
4 ページ
カタログアーカイブ
-
Cliniclave 45 M
12 ページ
-
Vacuklav 40 B+
12 ページ
-
MELAseal Pro
4 ページ
-
MELAquick 12+
6 ページ
-
Cliniklav®25
12 ページ
-
MELA quick®12+ p
2 ページ
-
The Premium-Plus-Class
12 ページ