Modus QA - Product Data Sheet - MRID3D
1 / 2ページ

{{requestButtons}}

カタログの抜粋

Modus QA - Product Data Sheet - MRID3D - 1

WORKFLOW EFFICIENCY GEOMETRIC ACCURACY Quickly setup, scan and quantify geometric distortion measurements in as little as 10 minutes with a lighter, larger and faster analysis system. Large FOV phantom design follows recommendations from NEMA/ MITA MS-12 and IEC 62464-1 for highest accuracy even when distortion is high and vendor correction is off. DIMENSIONAL STABILITY Integrated expansion tubes (patent pending) compensate for changes in liquid volume, caused by changes in temperature and pressure, ensuring the phantom is dimensionally stable. HARMONIC ANALYSIS Adapts analytical techniques that are routinely used in MRI B0 shimming and gradient coil design. QUASAR™ MRID3D is a lighter, larger and more efficient measurement technique that leverages harmonic analysis to quantify MRI geometric distortion in 3D. Harmonic analysis is a well-established mathematical tool used to solve electromagnetism problems with well-defined boundary conditions including MRI gradient coil design and B0 shimming. The QUASAR MRID3D Geometric Distortion Analysis System extends this approach by measuring distortions on the closed surface of a boundary phantom and then uses harmonic analysis to calculate the distortions inside. This permits the use of a lighter, larger, hollow boundary phantom. At 21 kg, the 39.4 cm diameter by 39.1 cm long phantom is half the weight of a water-filled grid phantom of the same volume. It includes recessed handles for safe carrying plus integrated 3 point contact feet and engraved landmarks for convenient OSHA compliant (under 50 lbs.) one person set-up. Fiducials in the acrylic phantom contain susceptibility matched mineral oil for fast high contrast 3D T1W scanning. Mineral oil is non-reactive and allows plastics to remain dimensionally stable over time unlike water which causes plastics to swell. The maintenance free phantom never has to be drained or refilled. The low dielectric constant mineral oil permits dielectric-resonance-free use at high field strengths. The system includes robust, mature, client-based image analysis software. The built-in DICOM receiver ensures efficient file transfer. There is no waiting for files to upload to the cloud thus avoiding associated IT issues. Control point detection and harmonic analysis are fully automated; from phantom setup to results in as little as 10 minutes. Software features include the

カタログの1ページ目を開く
Modus QA - Product Data Sheet - MRID3D - 2

ability to separate distortions caused by main magnetic field inhomogeneities from those caused by gradient non-linearities. A region of interest selector allows users to focus their analysis on targeted regions for more demanding applications such as SRS. A rich set of data presentation tools allows trending and comparison amongst a diverse selection of phantom scans. Users can export customizable automated reports including full DVF spreadsheets. The modern approach of QUASAR MRID3D is a better, faster and lighter alternative for routine distortion assessment. GRID phantoms are either too...

カタログの2ページ目を開く

Modus Medical Devicesのすべてのカタログと技術パンフレット

  1. PRODUCT CATALOG 2022

    13 ページ

  2. QUASAR™ GRID3D

    2 ページ

  3. QUASAR™ MRID3D

    2 ページ

  4. QUASAR MRID3D

    2 ページ

  5. QUASAR Penta-Guide

    2 ページ

  6. QUASAR? eQA

    2 ページ

  7. QUASAR ADQ

    2 ページ