Multiphoton Confocal Microscope A1 MP+/A1R MP+ NIKON CORPORATION Fuji Bldg., 2-3, Marunouchi 3-chome, Chiyoda-ku, Tokyo 100-8331, Japan www.nikon.com/ Multiphoton confocal microscope

カタログの1ページ目を開く
A1 MP+ / A1R MP+ - 2

The A1 MP+/A1R MP+ multiphoton confocal microscopes provide faster and sharper imaging from deeper within living organisms, extending the boundaries of traditional research techniques in biological sciences. •Ultrahigh-speed imaging up to 420 frames per second (fps) (512 x 32 pixels) with multiphoton imaging using A1R MP+’ high efficiency optics and resonant scanner. • Deep specimen imaging with high-sensitive non-descanned detectors (NDD) located close to the back aperture of the objective lens. A new model of an ultrasensitive gallium arsenide phosphide (GaAsP) NDD for upright microscopes...

カタログの2ページ目を開く
A1 MP+ / A1R MP+ - 3

Ultra-deep imaging of living specimens The ultrasensitive GaAsP NDD allows clear in vivo imaging in deeper areas than ever before and is powerful enough to analyze the mechanisms, such as brain neurons, of living specimens. In addition to a model compatible with a wavelength of 1080 nm, there is a new one for upright microscopes that is compatible with a wavelength of 1300 nm. This new NDD enables deep imaging up to 1.4 mm in combination with a newly developed scanning head A1R MP+ that is compatible with a wavelength of 1300 nm. Mouse brain in vivo dual color imaging with the GaAsP NDD...

カタログの3ページ目を開く
A1 MP+ / A1R MP+ - 4

Channel unmixing Fast multiphoton imaging, powerful enough for in vivo imaging Channel unmixing The Nikon resonant scanner is capable of high-speed 420-fps imaging, the world’s fastest for a multiphoton microscope using point scanning technology. Unique to this design is a resonant scan mirror capable of imaging full fields of view at much higher speeds than traditional galvano scanners. Nikon's optical pixel clock system, which monitors the position of the resonant mirror in real time, adjusts the pixel clock to ensure more stable, geometrically correct and more evenly illuminated imaging...

カタログの4ページ目を開く
A1 MP+ / A1R MP+ - 5

Channel unmixing Multiphoton imaging gallery Four-color imaging of human colon cancer cells in in vivo SHG image of the brain surface of a mouse Three-dimensional volume rendering of implanted subcutaneous tumor of HCT116 expressing Fucci. The cell cycle of tumor cells and the environment (collagen fiber and vessels) are visualized. Upper right, only collagen fiber and vessels are shown. The neocortex of an H-line 5-week-old mouse was studied with the open skull method. The SHG signals from dura mater and EYFP fluorescence signals were simultaneously acquired using the NDD. Red: Fucci...

カタログの5ページ目を開く
A1 MP+ / A1R MP+ - 6

A1 MP+/A1R MP+ achieve the most advanced multiphoton imaging Standard NDD Nikon’s high-NA objectives are ideal for multiphoton imaging The fluorescence emissions from deep within a specimen are highly scattered in multiphoton excitation, and therefore the conventional detector using a pinhole cannot provide bright fluorescent images. The episcopic NDD in the A1 MP+/A1R MP+ is located close to the back aperture of the objective to detect the maximum amount of scattered emission signals from deep within living specimens. The use of this four-channel detector in combination with special...

カタログの6ページ目を開く
A1 MP+ / A1R MP+ - 7

Two types of scanning head enable high-speed, high-quality imaging A1 MP+ is equipped with a galvano (non-resonant) scanner for high-resolution imaging. A1R MP+ is a hybrid scanning head that incorporates both galvano and ultrahigh-speed resonant scanners. A1R MP+ allows imaging and photoactivation at ultrafast speeds necessary for revealing cell dynamics and interaction. Ultrafast photoactivation and imaging High-resolution imaging Photoactivation during fluorescence imaging can be conducted using both galvano and resonant scanners. Two types of A1R MP+, the conventional 1080 nm type and...

カタログの7ページ目を開く
A1 MP+ / A1R MP+ - 8

Key Nikon innovations for improving image quality Enhanced spectral detector The best image quality is achieved by an increased light sensitivity resulting from comprehensive technological innovations in electronics, optics and software. Nikon’s original spectral performance is even further enhanced in the A1 MP+ series, allowing high-speed spectral acquisition with a single scan. In addition, advanced functions, including real-time unmixing, are incorporated. Low-angle incidence dichroic mirror With the A1 MP+ series, the industry’s first low-angle incidence method is utilized on the...

カタログの8ページ目を開く
A1 MP+ / A1R MP+ - 9

Intuitive, easy-to-use software for multiphoton imaging NIS-Elements C Acquisition and Analysis software Simple operations common with Nikon confocal microscopes Channel unmixing function Microscope control •All necessary operations for image capture are displayed in one window. •Lasers and detectors for visible laser excitation can be switched simply by selecting fluorescent probe to be used. •One-touch switching of high speed resonant scanner and high-resolution galvano (non-resonant) scanner •Simultaneous photoactivation with high speed imaging is possible with visible laser excitation....

カタログの9ページ目を開く
A1 MP+ / A1R MP+ - 10

System diagram ^ Laser Unit for Multiphoton Microscopy ^ Chameleon Vision II MaiTaiHP/eHP InSight DeepSee*1 Laser Unit for Confocal Microscopy ^ LU-LR 4-laser Power Source Rack ^ Detector Unit for Confocal Microscopy^ A1-DUS Spectral Detector Unit Filter Cubes ^ Incident Optical Unit ^ ^ Scan Head and Controller ^ Scan Head Detector Unit for Multiphoton Microscopy Diascopic Non-descanned Episcopic Non-descanned Detector (Standard/ (Standard/ Filter Cubes *1 When using a scan head for 1300 nm *2 When using Spectral Detector Unit. *3 Dedicated adapter is required depending on microscope...

カタログの10ページ目を開く
A1 MP+ / A1R MP+ - 11

Laser Chiller for Multiphoton Microscopy Incident Optical Unit Incident Optical Unit Laser for Multiphoton Microscopy Laser Controller for Multiphoton Microscopy Laser Controller for Multiphoton Microscopy Scan Head Scan Head Non-Descanned Detector Vibration Isolated Table Non-Descanned Detector 4 Detector Unit, Spectral Detector Unit, Controller Vibration Isolated Table 4 Detector Unit, Spectral Detector Unit, Controller Laser Chiller for Multiphoton Microscopy 4-laser Module A, 4-laser Power Source Rack Approx. 2750 4-laser Module A, 4-laser Power Source Rack Laser for Multiphoton...

カタログの11ページ目を開く

Nikon Instrumentsのすべてのカタログと技術パンフレット

  1. HCA

    8 ページ

  2. DS-Fi3

    16 ページ

  3. ShuttlePix

    8 ページ

  4. A1 MP+ / A1R MP

    15 ページ

  5. A1 HD25 / A1R HD25

    15 ページ

  6. TI-E

    32 ページ

  7. ECLIPSE TS2

    8 ページ

  8. ECLIPSE TS2R

    8 ページ

  9. N-SIME

    6 ページ

  10. N-SIM N-STORM

    24 ページ

  11. ECLIPSE E100 LED

    8 ページ

  12. Bio Station IMQ

    8 ページ

  13. ECLIPSE Ti2

    24 ページ

  14. A1 MP+ / A1R MP+

    20 ページ

  15. DIGITAL SIGHT SERIES

    16 ページ

  16. NeoScope Brochure

    16 ページ

  17. Eclipse FN1

    12 ページ

  18. Eclipse Ti

    32 ページ

  19. C2 Plus

    16 ページ

  20. A1+ / A1R+

    13 ページ

  21. Stereomicroscopes

    32 ページ

  22. SMZ18

    16 ページ

  23. N-SIM E

    4 ページ

  24. N-STORM 4.1

    13 ページ

  25. A1_MP

    11 ページ

  26. AZ_C1

    2 ページ

  27. MiBrochure

    2 ページ

  28. A1+_A1R+_2CE-SBTH-9

    13 ページ

  29. C2+_2CE-SCHH-5

    16 ページ

  30. NIS-Elements

    8 ページ

  31. ShuttlePix P-400R

    5 ページ

  32. AZ100M

    8 ページ

  33. AZ100

    4 ページ

  34. Eclipse E200POL

    3 ページ

  35. Eclipse E100 LED

    4 ページ

  36. Eclipse Ci-E/ Ci-L

    5 ページ

  37. Eclipse Ni

    15 ページ

  38. Eclipse E200 POL

    3 ページ

カタログアーカイブ

  1. Eclipse E100-LED

    8 ページ