
カタログの抜粋

EtCO2 technology ® Accurate and Fast First Breath Technology Key Features: » Superior Optical Bench – accurate and stable measurements » Fast-First-Breath Reading – because time matters MedAir EtCO2 Accuracy Measured Values Across Range of Test Gas Values 12.0 Test Value MedAir EtCO2 10.0 10.0 RespSense ™ 9.2 WIDESCREEN™ Capnography 8.0 6.0 5.0 5.0 4.0 2.5 2.5 2.0 Superior EtCO2 Technology for Accurate and Fast Monitoring 0.0 MedAir™, a leader in high performance EtCO2 technology, uses a low flow Six-Hour Drift Assessment sidestream technology designed to monitor the respiratory status of intubated 8.0 or spontaneously breathing patients. The core technology utilizes a stable Reference Gas Value: 5.0 6.0 5.3 5.0 optical bench to provide a fast and accurate measurement. Unlike other 5.3 technologies that require an integrated solenoid valve for auto-zeroing, the 4.0 MedAir EtCO2 optical design provides continuous monitoring by eliminating 2.0 the need to interrupt patient measurement to compensate for drift. 0.0 Time=0 Hr Time=3 hr Testing conducted by independent laboratory, Intertek Semko AB in Kista, Time=6 hr Sweden, in accordance with ISO 21647 standards, verified MedAir’s EtCO2 MedAir Respiratory Rate Accuracy* Measured Values Across Range of Simulated Respiratory Rates CO2 for six hours of continuous monitoring. Simulated Respiratory Rate 90 superior accuracy. The drift of measurement accuracy was tested with 5.0% MedAir Reading 80 83 80 70 70 60 60 50 50 57 68 MedAir EtCO2 technology utilizes advance algorithms to provide an accurate respiration reading. Following the first breath, the EtCO2 module adapts to a 50 40 35 34 30 20 20 19 10 3 3 0 *Testing conducted at Nonin Medical, Inc. fast averaging based on two breaths.
カタログの1ページ目を開く
EtCO2 technology Other Features: Specifications » Non-Proprietary Tubing – reduces operation costs » Advanced Moisture Management – for high humidity environments Sample Line Options: Infant to Adult CO2 Nasal Sampling Cannulas Straight T-connector Sample Line Nafion Tubing Operation Working temperature: -5° to +40°C (23° to 104°F) Humidity: 10 – 90% (non-condensing) Atmospheric pressure: 860 – 1060 hPa Storage Storage temperature: -20° to +50°C (-4° to +122°F) Humidity: 10 – 95% (non-condensing) Atmospheric pressure: Up to 4 atmospheres (110 - 4050 hPa) Pump Pump flow: Flow accuracy: 75...
カタログの2ページ目を開くNoninのすべてのカタログと技術パンフレット
-
8204CA
4 ページ
-
8000 series
2 ページ
-
6000 C series
2 ページ
カタログアーカイブ
-
Narcotrend Compact-M
2 ページ
-
9840/8500 Series
1 ページ
-
Onyx III 9591
2 ページ
-
USB-Desaturation
1 ページ
-
Capnography-for-CPR.
2 ページ
-
Nonin3230-3231
4 ページ
-
RespSense
2 ページ
-
Why Nonin Sensors
4 ページ
-
PureSAT Advantage
2 ページ
-
Product Catalog
21 ページ
-
Avant 2120
2 ページ
-
Model 7500 Series
2 ページ
-
3150 Sleep Flyer
2 ページ
-
Nonin Onyx Brochure
6 ページ
-
LifeSense®
2 ページ
-
9840 Series
2 ページ
-
ipod Specifications
6 ページ
-
Vet Family Brochure
4 ページ
-
OEM Xpod Brochure
2 ページ
-
Avant® 9600
2 ページ
-
Avant® 9700
2 ページ
-
Model 8500 Series
2 ページ
-
EQUANOX?, Model 7600
2 ページ
-
Cloth 6000C Series
2 ページ
-
Onyx Vantage 9590
2 ページ
-
Dr Petty GO2 Brochure
13 ページ
-
nVision
4 ページ
-
2500A VET Spec Sheet
2 ページ
-
9847V Brochure
2 ページ
-
LifeSense® Old
2 ページ
-
WristOx2?
2 ページ
-
Model 7500
4 ページ
-
Avant® 9600
1 ページ
-
9500 Spec Sheet
2 ページ
-
Onyx® II 9550
2 ページ
-
Onyx9550
4 ページ
-
Onyx® II, Model 9560
4 ページ
-
Product catalog
21 ページ