カタログの抜粋

Oicumnn Healthcare OKm800 Multi-Parameter Monitor Ideal Multi-Parameter Monitor for Monitoring of Large Intensive Care and Anesthesia Parameters from Basic Patient Parameters
カタログの1ページ目を開く
Performance Specifications 12.1” color TFT touch screen Parameters convenient for use in adult, pediatric and neonatal patients Waveform monitoring up to 9 channels Electronic keyboard on screen for inputting information Interchangeable waveform colors Ability to control all alarms from a single. Drug dose calculation program for 15 different drugs Educational demo feature OxyCRG software 3, 7 or 12 lead ECG measurement with 3, 5 or 10-electrodes ECG cable Extended arrhythmia analysis and ST segment analysis Easy monitorization with large numerical value and waveform selection Suitable...
カタログの2ページ目を開く
Interface Parameter cable interface AC power input socket Software upgrade through networking port& USB port RJ45 port Nurse call port Indicator One alarm indicator (C80) Power indicator Battery indicator QRS beep and alarm sound Operating key sound Alarm Event Recall Wave Recall NIBP Recall Trend Graph Trend Table Power-off storage Alarm Network ECG Lead Type 12-lead cable 5-lead cable 3-lead cable Lead selection Gain Selection Sweep Speed Heart Rate Range Resolution Protection Accuracy Bandwidth ST detection Arrhythmia analysis Pacemaker detection 500 groups(120hours) 6 hours 2000 groups...
カタログの3ページ目を開く
Temperature (Dual Channel) Range 0-50°C
カタログの4ページ目を開く
End Tidal Karbon Dioksit (EtCO2) / Respironics EtCO2(Sidestream) Technical principle Dual waveband, non-dispersive infrared (NDIR)single beam optics Initialization time Capnogram,displayed in less than 20 seconds, at an ambient temperature of 25°C, full specifications within 2 minutes CO2 measurement range 0-150 mmHg, 0-19,7%, 0-120kPa CO2 stability Sampling rate Respiratory rate range Respiratory rate accuracy Calibration Water resistance Data output 0.1mm Hg (0 to 69 mm Hg) 0.25mm Hg (70 to 150 mm Hg) 0-40mm (±2 mm Hg) 41-70mm Hg (±5% of reading) 71-100mm Hg (±8% of reading) 101-150mm Hg...
カタログの5ページ目を開く
Okuman(EtCO2)-Sidestream) Technical principle Initialization time CO2 measurement range Rise time C02 resolution CO2 accuracy CO2 stability Sampling rate Respiratory rate measurement range Dual waveband, non-dispersive infrared (NDIR) Full specifications within 3 seconds, waveform data in less than 3 seconds 0-114 mmHg, 0-15%, 0-15.2kPa Sidestream <3 s (dependent on the flow rate and the length of sampling tube) 0.1mm Hg (0 to 59 mm Hg) 0.25mm Hg (60 to 114 mm Hg) 0-40mm (±2 mm Hg) 41-76mm Hg (±5% of reading) 77-114mm Hg (±8% of reading) Respiratory rate above 80 BPM (±12% of reading )...
カタログの6ページ目を開く
IBP Channel: Measured Pressure: Measurement Range: IBP Accuracy: Alarm Range: Multi-Gas/02 Method Gas sorts Measurement range Data output Respiratory rate Preheating time Alarm Others Infrared Absorption C02,N20,Des,lso,Enf,Sev,Hal,02 (optional paramagnetic sensor) C02 : 0-15 vol%: ±(0.2 vol% + 2 % of the reading), 15-25vol %: unspecified N2O: 0-100 vol%: ±(2 vol% + 2 % of the reading) HAL, ISO, ENF: 0-8 vol%: ±(0.15 vol% + 5 % of the reading); 8-25vol %: unspecified SEV: 0-10 vol%:±(0.15 vol% + 5 % of the reading); 10-25vol %: unspecified DES: 0-22 vol%: ±(0.15 vol% + 5 % of the reading);...
カタログの7ページ目を開く
© 2018 OKUMAN Medikal Sistemler A.S All rights reserved. Technical specifications are subject to change by OKUMAN without prior notice. OKUMAN Medikal Sistemler A.S Kazım Karabekir Caddesi 95/95 06060 Iskitler Ankara / TURKEY T: +90 312 384 0520 F: +90 312 384 1975 info@okuman.com.tr www.okuman.com.t