TREND II BILEVEL ST30
1 / 2ページ

カタログの抜粋

TREND II BILEVEL ST30 - 1

Enhanced data management with SD card • Simple handling • Data storage and transfer • AI, leakage values, enhanced compliance analysis, respiratory ow and much more The comprehensive therapy data are analyzed, adjusted and managed with the aid of the TRENDset PC software. Additionally, the AI, increased leakage values and the average daily operation can be displayed on the device itself. The TREND II BILEVEL ST30 automatically applies altered therapy settings after insertion of the SD card. Enhanced elds of application through new features • High maximum pressure 30 hPa I-pressure E-pressure • Target volume with adjustable pressure Trigger function in BILEVEL-devices • Tidal volume display • Enhanced data management with SD card The TREND II Bilevel ST30 provides additional safety for the user through a backup fre- Respiratory flow TREND II BILEVEL ST30 features two pressure levels (I-pressure and E-pressure). The trigger, which can be separately adjusted for inspiration and expiration, is especially suited for shallow breathing and effectively prevents undesired self-triggering. The volumecontrolled inspiration trigger and the ow-controlled expiration trigger can be set to three different levels. A latency period of up to 20 seconds can also be set, after which time the ventilation function (T mode) starts. When spontaneous breathing is reinstated, the device automatically switches back to the S mode. quency in the S mode and alarms for apnea and low respiratory minute volume. The proven therapy, comfort and safety functions of the TREND II series (including the TREND II BILEVEL ST30) continue to assure effective and comfortable therapy, optionally with air humidication. I-pressure E-pressure Adjustable latency period in BILEVEL ST devices

カタログの1ページ目を開く
TREND II BILEVEL ST30 - 2

Technical data TREND II BILEVEL ST30 Dimensions (W x H x D) Weight Operating voltage Pressure range Pressure uctuations Noise level Data management Modes Languages Meter Displays CPAP, BILEVEL S, BILEVEL T, BILEVEL ST eng, deu, fra, ita, pol, nld, spa (further on request) operating time, motor runtime, therapy time, lter age pressure, bar graph, tidal volume, current mode (S, T), date, time, soft start ramp, alarm clock status automatic start stop, soft start ramp, leakage test, leakage warning, alarm on power failure, automatic start after power failure, date and time display, alarm clock...

カタログの2ページ目を開く

Orbisanaのすべてのカタログと技術パンフレット

  1. point 2

    2 ページ

  2. HOFFRICHTER LAVI

    2 ページ

  3. CARAT pro

    2 ページ

  4. Masquerade

    2 ページ

  5. CARAT Pro

    2 ページ

  6. AUTOFLEX

    2 ページ

  7. Comfort Tube

    2 ページ

  8. Acessories

    2 ページ

  9. TREND 500

    2 ページ

  10. AKKUPACK uni

    2 ページ

  11. point 2

    2 ページ

  12. PasCal CPS

    4 ページ

  13. TRENDvent

    2 ページ

  14. VECTOR et

    2 ページ

  15. PasCal

    12 ページ

  16. CARAT

    2 ページ

  17. TREND II

    2 ページ