V8800 Ventilator System
1 / 2ページ

カタログの抜粋

V8800 Ventilator System - 1

Your healthcare, we care. V8800 Ventilator Technical Parameters V8800 Modes of Ventilation Monitoring ·Volume Controlled (VCV), Assist/Control ·Pressure Controlled (PCV), Assist/Control ·Pressure Regulation Volume Controlled (PRVC), Assist/Control ·Synchronized Intermittent Mandatory Ventilation, SIMV(VCV) + PSV, SIMV(PCV) + PSV, SIMV(PRVC) + PSV ·Spontaneous Ventilation (SPONT/CPAP) + PSV ·Bi Level Ventilation (BIVENT/APRV) + PSV ·Non-invasive Ventilation (NIV/CPAP + PSV, NIV/PCV) ·Pressure values: Pmin, Pplat, Pmean, Ppeak, PEEP ·Volume/Flow values: VTI, VTE, MV, MVspont, Leak% ·Loops: Flow – Pressure, Pressure - Volume, Flow - Volume ·FiO 2 ·Optional EtCO 2 Parameters and Ranges ·Tidal volume: 20-2500ml ·Respiratory rate: 1-120bpm ·Inspiration time: 0.2-9s ·Inspiratory pause time: 0~4s ·Tslope: 0~2s ·FiO 2 : 21%~100% ·PEEP: 0-50cmH 2 O ·CPAP(NIV): 2-20cmH 2 O ·Psupport: 0-90cmH 2 O ·Pinsp: 5-90cmH 2 O ·Phigh: 5-90cmH 2 O ·Plow: 0-50cmH 2 O ·Esens: 5%~80% ·Flow patterns: square, decelerating ·Inspiratory hold ·Expiratory hold ·Nebulizer: 30 or 45 minutes ·Auto tube compensation (ATC) ·Compliance compensation ·Graphical trends ·Nurse call Ventilator System Alarms MV high, MV low, Circuit disconnect, Paw high, Paw low, Continuous airway pressure high, VTi high, fspont high, Tapnea, FiO 2 high, FiO 2 low, EtCO 2 high, EtCO 2 low, Power supply failure, Battery low, Battery exhausted, Air supply failure, O 2 supply failure, PEEP low, etc Operating Conditions ·Gas supply: O 2 , Air, 200kPa -650kPa (29 – 94 PSI) ·Power supply: 100-240V, 50-60Hz ·Temperature: 10-40℃(Operation) ·-20-60℃ (Storage) ·Relative humidity: 15-95%, non-condensing (Operation) ·≤95%, non-condensing (Storage) ·Atmospheric pressure: 500hPa-1060hPa (Operation & Storage) ·Communication interfaces: RS232, VGA, USB, RJ45 ·Dimensions (H×W×D): 624x774x1410mm (with Cart) Standards UL/IEC 60601-1, IEC 60601-1-2, IEC 60601-2-12, EN 794-1 Oricare, Inc. 1900 AM Drive Quakertown, PA 18951 USA VL9002 October 2011 Tel: +1-215-538-2470 Fax: +1-215-538-2578 www.oricaremed.com

カタログの1ページ目を開く
V8800 Ventilator System - 2

V8800 Ventilator System V8800 is a critical care ventilator for infants, children and adults. It has comprehensive functionality, a user-friendly design, and is full of high-quality, reliable treatment options for the clinician. V8800 Ventilator System Simple and intuitive interface: With a 15” TFT LCD touch screen and a simple intuitive interface, the user can easily complete the entire operation. At the same time the display can be rotated 180 degrees around the user in different directions, different angles of observation and action. Powerful monitoring functions: · Complete ventilation...

カタログの2ページ目を開く

Oricareのすべてのカタログと技術パンフレット

  1. V8600 Ventilator

    6 ページ

  2. L2700 Series

    6 ページ

  3. T3600

    16 ページ

  4. P1000 Series

    12 ページ

  5. V8800

    6 ページ

  6. A9800

    6 ページ

  7. M7600/M7400

    6 ページ

  8. M7800

    6 ページ

カタログアーカイブ