カタログの抜粋
PHARMA TECHNOLOGY CW-150 - CHECKWEIGHER FOR TABLETS & CAPSULES New and innovative in-line solution designed to ensure the quality of each individual tablet or capsule up to OEB3 level products. The CW-150 measures individual mass from each single tablet or capsule up to a speed of 150.000 objects per hour and rejects all non-compliant products. The ideal tool for in-line Quality Inspection and RTD (Real Time Decision). It can also be used off-line for batch recovery inspection. 100% weight control of tablets & capsules Upgradable to 100% Content Uniformity Weight + %APIs Single line system - less maintenance & calibration time Fast & Easy change-over
カタログの1ページ目を開くPHARMA TECHNOLOGY 3D MICROWAVE RESONATOR FOR: WEIGHT MEASUREMENT Each product is inspected by the 3D microwave resonator allowing to measure individual mass to the accuracy of +/- 1mg (3 sigma). Various extensive dies have shown boundaries. tests campaigns measurements are industrial case the predicted The CW-150 is geared to provide an accurate mass and to remove 100% non-compliant products from the the product stream, allowing RTD (Real Time Decision). The CW-150 use simple calibration protocol for calibrating & validating the 3D microwave resonator based on a multiple linear regression...
カタログの2ページ目を開くPHARMA TECHNOLOGY The unit has been developed with an utmost care to the mechanical design allowing fast and unexpansive format changes. Data are processed and analysed by high speed processors and stored in a userfriendly “step by step” CFR21 acquisition software. Data can easily be exported to an up-stream machine or software through OPC UA (e.g. connection to a upstream or downstream process equipment). A special care has been taken to simplify the equipment to allow use in a production environment. Automatic Calibration Automatic Calibration Designed to comply with common guidelines (i....
カタログの3ページ目を開くPHARMA TECHNOLOGY TECHNICAL SPECIFICATIONS Maximum throughput (size or shape dependent) Good products Non-compliant products Minimum product width (tablets) Maximum product width (tablets) Maximum product height (tablets) Size range (capsules) (hard gelatine) Weighing range 3D mass measurement accuracy Air extraction Requested compressed air Noise level Power supply 000 to 5 20mg to 2000 mg +/- 1mg (3 Sigma) Integrated with Hepa filter H13 500L/min - min. 6 bar ≤70 dB (A) 380V 3ph + N + PE Polymer contact parts
カタログの4ページ目を開くPharma Technologyのすべてのカタログと技術パンフレット
カタログアーカイブ
-
iTest 4P
2 ページ
-
CUB-20
4 ページ
-
iSort
2 ページ
-
iCaps
16 ページ
-
iSeries
24 ページ
-
PTC iSeries
2 ページ
-
PFC iSeries
2 ページ