
グループ: PHC Corporation
カタログの抜粋

CO2 & MULTIGAS INCUBATOR SERIES Optimising cell culture outcomes and reproducibility. IncuSafe Incubators offer the most precise and regulated environment. During cell culturing, the inCu-saFe germicidal interior and SafeCell UV lamp, work continuously to prevent contamination.
カタログの1ページ目を開く
THE INCUSAFE ADVANTAGE Combining advanced technology, unique design features and high-quality engineering, IncuSafe Incubators offer the most precise and regulated environment for cell culture. Providing outstanding performance and flexibility, this innovative range of incubators enables you to optimise results and reproducibility. The IncuSafe Advantage is delivered through three important benefits: A PRECISE & REGULATED ENVIRONMENT STERILISATION TO MEET EVERY NEED IncuSafe Incubators offer accurate, uniform and highly responsive control of conditions within the chamber. Temperature is...
カタログの2ページ目を開く
IncuSafe Multigas Incubators 165 litres Incubators 230 litres Incubators Optimising cell culture outcomes and reproducibility. So comfortable, your cells will feel in vivo. IncuSafe CO2 Incubators provide precise control of CO2 concentration and accurate, uniform, and highly responsive temperature control within the chamber. During cell culturing, the inCu-saFe germicidal interior and SafeCell UV lamp, work continuously to prevent contamination. PHCbi ffers two alternative sterilisation o methods for the CO2 Incubators to meet every need. IncuSafe Class IIa Medical Device certified, ultigas...
カタログの3ページ目を開く
PRECISE & REGULATED ENVIRONMENT: TEMPERATURE CONTROL Models: MCO-170AIC | MCO-170AICD | MCO-230AIC | MCO-170M Series DIRECT HEAT SYSTEM The Direct Heat System in the IncuSafe Incubators achieves an accurate, uniform, and highly responsive temperature control within the chamber. This system regulates temperature through three independent heating zones under microprocessor P.I.D* control. The system anticipates the amount of energy needed to recover chamber temperature for fast recovery times. *Proportional Integral Derivative Heat zones Side, top and rear walls form the dominant radiant heat...
カタログの4ページ目を開く
PRECISE & REGULATED ENVIRONMENT: CO2 AND O2 CONTROL & RECOVERY UV Exposed Time (Min.) (E.Coli: ATCC 8739) The single beam, dual detector IR CO2 Sensor offers continuous calibration for excellent control, accuracy and stability. The sensor simultaneously measures sample and reference wavelengths for continuous auto-zero calibration. The ceramic-based sensor is unaffected by moderate changes in temperature and relative humidity and is linked to the P.I.D. controller for fast recovery times. Survival Number (CFU/ml) Survival Number (CFU/ml) Survival Number (CFU/ml) The unique, solid state...
カタログの5ページ目を開く
ACTIVE BACKGROUND DECONTAMINATION - INCU-SAFE GERMICIDAL INTERIOR Models: MCO-170AIC | MCO-170AICD | MCO-230AIC | MCO-170M Series INCU-SAFE inCu-saFe germicidal interior prevents contamination. The exclusive inCu-saFe copper-enriched stainless steel alloy interor offers the germicidal properties of copper and the durability of stainless steel. Selected to provide passive germicidal protection without rust or corrosion, inCu-saFe expresses a natural germicidal effect, inhibiting the growth of molds, fungi, mycoplasma and bacteria on its surface continuously. All interior components,...
カタログの6ページ目を開く
ACTIVE BACKGROUND DECONTAMINATION - SAFECELL UV LAMP Models: MCO-170AIC | MCO-170AICD | MCO-230AIC | MCO-170M Series SAFECELL UV LAMP The programmable ultraviolet lamp, isolated from cell cultures, eliminates contaminants in the air-flow and water-pan without affecting cell cultures. SafeCell UV inhibits the growth of mycoplasma, bacteria, molds, spores, yeasts and fungi without costly HEPA filters that accumulate contaminants in the chamber air. Interior air motion is suspended when the door is opened, minimising movement of room air contaminants into the chamber. Airflow & waterpan...
カタログの7ページ目を開く
STERILISATION METHODS - H2O2 DECONTAMINATION TECHNOLOGY H2O2 DECONTAMINATION ECHNOLOGY T The unique H2O2 decontamination system delivers fast and validatable decontamination. The high-speed decontamination system uses vaporised hydrogen peroxide and UV light. It cleans the chamber of the incubator safely in less than three hours, achieving a minimal 6 log reduction of major contaminants. STEP 1 HOW DOES IT WORK? 1. ydrogen peroxide (aqueous) is converted to vapour using H high frequency ultrasonics. During this process, the fan motor remains active, ensuring H2O2 vapour accesses every point...
カタログの8ページ目を開く
STERILISATION METHODS - DUAL HEAT STERILISATION Models: MCO-170AIC(UV)D DUAL HEAT STERILISATION DUAL HEAT STERILISATION CYCLE Dual heat sterilisation utilises the incubator’s two heaters during the 180°C sterilisation process, which takes 11 hours. There is no effect on temperature inside stacked incubators due to low heat dissipation, so cell culturing can continue uninterrupted. There is no need to remove inner parts such as the CO2 sensor and UV light, or recalibrate after sterilisation, therefore, laboratory processes are more efficient with less incubator downtime. Preparation time: 10...
カタログの9ページ目を開く
OPTIMUM CELL GROWTH & MORE SPACE FOR MORE CULTURES Models: MCO-170AIC | MCO-170AICD | MCO-230AIC | MCO-170M Series INTEGRATED SHELF SUPPORTS INCREASED CAPACITY Save valuable time and reduce the risk of contamination with an easy to clean incubator interior featuring fully rounded corners and integrated shelf supports. With integrated shelf supports, the IncuSafe MCO-170AIC(D), MCO-170M and the MCO-230AIC incubators provide space for up to 20-25%* more culture vessels. Latest IncuSafe incubators Traditional incubator MCO-230AIC Series 24 petri plates (90 mm dishes) MCO-170AIC/M Series, 20...
カタログの10ページ目を開く
LCD TOUCH PANEL Models: MCO-170AIC | MCO-170AICD | MCO-230AIC | MCO-170M Series ADVANCED TOUCH PANEL Touch panel legend A colour LCD touch panel delivers full control over the incubator. Control can be performed with gloved hands. USB Data storage and transfer The standard USB port allows for convenient transfer of log data from a USB memory stick to a computer. Data is logged for approximately 1.5 months, using a 2-minute interval. (Settable range: 2~30 min.) Electric door lock Automatic door lock with password protection is available as a standard feature for the...
カタログの11ページ目を開くPHC Europe B.V. / PHCbiのすべてのカタログと技術パンフレット
-
ProteoSave™ Brochure
2 ページ
-
STEMFULL™ Brochure
2 ページ
-
iP-TEC® General Brochure
12 ページ
-
PATHFAST™ Presepsin
6 ページ
-
General Catalogue
60 ページ
-
Vaccine Storage E-Book
14 ページ
-
MDF-C2156VANW-PE
16 ページ
-
MDF-DU901VHL-PE
2 ページ
-
VIP Brochure
16 ページ
-
MPR-N450FHD-PE
2 ページ
-
PRIMESURFACE®
4 ページ
-
MPR-1014R-PE
2 ページ
-
MPR-N450FH-PE
2 ページ
カタログアーカイブ
-
MLS
2 ページ
-
Incubateurs multigaz
2 ページ
-
MDF-DU302VX-PE
2 ページ
-
Cooled Incubators
4 ページ
-
MDF-U5386S-PE
2 ページ
-
MDF-U4186S-PE
2 ページ
-
MDF-U3386S-PE
2 ページ
-
MDF-U5412-PE
2 ページ
-
MDF-U731M-PE
2 ページ
-
MIR-H163-H263
2 ページ
-
MDF-U500VX-PE
2 ページ
-
MDF-U700VX-PE
2 ページ
-
MIR-162/262
2 ページ
-
Biomedical Freezers
4 ページ