カタログの抜粋
VERTEBRIS cervical Full-endoscopic Decompression of the cervical spine posterior and anterior techniques
カタログの1ページ目を開くRICHRRD nrin VERTEBRIS cervicalFull-endoscopic Spine Instrumentation spirit of excellence Contents VERTEBRIS cervical The full-endoscopic posterior technique ■ Storage i Determination of the access ■ Implementation of the access i Operating procedure The full-endoscopic anterior technique ■ Storage i Determination of the access ■ Implementation of the access i Operating procedure VERTEBRIS cervical Instrumentation ■ VERTEBRIS cervical posterior 14 i VERTEBRIS cervical anterior 16 ■ Radioblator RF 4 MHz - Multidisciplinary Radiofrequency Surgical System 20 ■ PowerDrive ART1 -...
カタログの3ページ目を開くVERTEBRIS cervical Foreword In the area of the cervical spine, radicular symptoms due to degenerative causes, in other words pain in the arms, are typically caused by mediolateral to lateral spinal disk herniations or stenoses of the intervertebral foramen. At the beginning of the 1940s, the clinical symptoms of this nature with a topographical reference to changes in the cervical disks were classified for the first time. Although good results are frequently obtained using conservative methods, surgical intervention may become necessary in the presence of pain or neurological deficits. The...
カタログの4ページ目を開くthe spinal column - and different surgical instruments provide technical conditions akin to conventional microscopically assisted surgical inventions with the simultaneous advantages of the full-endoscopic approach with 25° telescopes with a continuous flow of fluid.1 The main indications for cervical full-endoscopic operations are "soft" spinal disk herniations with radicular symptoms, in other words pain in the arms. Since the cervical spinal cord cannot be manipulated medially, the posterior approach is used for herniations where the main section is localized laterally to the...
カタログの5ページ目を開くVERTEBRIS cervical The full-endoscopic posterior technique Storage The operation is performed with the patient in the prone position lying on a hip and thorax roll. The head and the cervical spine must be resting with correct lordotic adjustment in a fixed position in keeping with a posterior intervention on the cervical spine. X-ray monitoring should be permitted during the operation in two planes. General fixation in the Mayfield Clip or a similar holder offers excellent prerequisites and always provides the circumstances for an open Prone position, fixation of the head in the Mayfield...
カタログの6ページ目を開くImplementation of the access After determining the entry point in the skin and carrying out a stab incision, the dilator is inserted until contact is made with bone on the zygoapophyseal joint under lateral image intensifier control. The working sleeve with oblique opening is pushed through the dilator in a medial direction and the dilator is removed. Insertion of the dilator in the zygoapophyseal joint The operating sleeve is inserted through the dilator Operating procedure The endoscope is inserted through the working sleeve. The operation is carried out in vision using different...
カタログの7ページ目を開くBony parts of the joint and the lamina are resected to open the foramen The image intensifier can help with orientation during cutting or when working in the spinal canal Reamed foramen with view of the liga- View in the lateral spinal canal with mentum flavum cervical spinal cord and spinal nerve
カタログの8ページ目を開くAfter removal of the lateral ligamentum flavum and exposure of the neural structures, the spinal disk herniation can be removed. The locking caps for telescope and working sleeve should only be used briefly if bleeding obscures visibility since when operations last a long time and the drainage of fluid is prevented without being noticed, the consequences of volume overload and elevated pressure within the spinal canal and the associated and neighboring structures cannot theoretically be completely excluded. Any manipulation of the spinal cord must be avoided. Experience indicates that...
カタログの9ページ目を開くVERTEBRIS cervical The full-endoscopic anterior technique Storage The patient is placed in a supine position. The head and cervical spine must be placed in a slightly reclining position and fixed in keeping with an anterior approach to the cervical spine. X-ray monitoring should be permitted in two planes during the procedure. General fixation in the Mayfield Clip or a similar holder offers excellent prerequisites and always provides the circumstances for an open intervention if an emergency occurs. Particularly in the case of the lower cervical spine, it may be necessary to tape the...
カタログの10ページ目を開くImplementation of the access After determining the entry point in the skin and carrying out a stab incision in the skin, the first thin dilator is inserted in the intervertebral space under lateral image intensifier control. It is important to make an anterior puncture in the spinal disk and not to miss laterally. This not only precludes further operations but can also lead to injury of the vertebral artery, spinal nerve or esophagus. Alternatively, the spinal disk can be punctured using a spinal cannula and a guide wire is inserted through this. The first dilator can then be pushed through...
カタログの11ページ目を開くVERTEBRIS cervical The full-endoscopic anterior technique Operating procedure The endoscope is inserted through the working sleeve. The operation is carried out in vision using different instrument sets positioned through the intra-endoscopic working channel and with a continuous flow of liquid. On the side of the pathology, the uncinate process, posterior edge of the spine vertebral body and the posterior annulus are dissected contralaterally for purposes of topographical orientation. Bone resection with different instrument is necessary in many cases in order to reach the epidural space....
カタログの12ページ目を開くBony resection is frequently necessary to reach the spinal canal Depending on the findings, the dorsal longitudinal ligament should be opened The locking caps for the telescope and the working sleeve should only be used at short notice for hemorrhage that obscures vision because if operations extend over a long period and if the drainage of the irrigation fluid is inadvertently obstructed the consequences of volume strain and pressure increase cannot be entirely excluded within the spinal canal and the associated and adjacent structures. Any manipulation of the cervical spinal cord must be...
カタログの13ページ目を開くRichard Wolfのすべてのカタログと技術パンフレット
-
FLUID CONTROL 2225
12 ページ
-
Catalogue Urology
466 ページ
-
Catalogue Orthopedics
218 ページ
-
Catalogue OR Integration
36 ページ
-
Catalogue Gynecology
248 ページ
-
Catalogue General surgery
222 ページ
-
Catalogue Traitement
58 ページ
-
ERAGON modular
28 ページ
-
LEVD
8 ページ
-
ENT catalogue
426 ページ
-
COXARTIS Brochure
12 ページ
-
MegaPulse 70+ Flyer
2 ページ
-
ERAGON
8 ページ
-
PANOVIEW ULTRA
4 ページ
-
Fiber light cables
4 ページ
-
Endocam Logic HD
12 ページ
-
ENDOLIGHT LED
6 ページ
-
FLUID CONTROL Arthro
4 ページ
-
ENDOCAM Flex HD
12 ページ
-
core nova
8 ページ
-
ZeroWire Brochure
2 ページ
-
core.media Brochure
2 ページ
-
core nova Brochure
8 ページ
-
Sterisafe® DURO A3
4 ページ
-
Eragon Modluar Mini
8 ページ
カタログアーカイブ
-
T-Lock OSTEOTRANS
6 ページ
-
COMBIDRIVE EN Brochure
20 ページ
-
TipControl Brochure
4 ページ
-
arthroLution Folleto
4 ページ
-
RECTO PUMP Brochure
2 ページ
-
VictOR HD Brochure
6 ページ
-
Reprocessing baskets
2 ページ
-
B 774 Key Port I13 GB
12 ページ
-
B 775 LEVD XI12 GB
6 ページ
-
B 920 TEM D GB VI10
18 ページ