カタログの抜粋

Evening Seminar at the 83rd Annual Meeting of the Japanese Orthopaedic Association Clinical Applications Slot Radiography and Dual Energy Subtraction — Imaging technique and clinical application to orthopaedics Takatoshi AOKI Associate Professor, Department of Radiology, University of Occupational and Environmental Health Utility of Tomosynthesis and Slot Radiography Hiroyuki TSUCHIYA Professor and Chairman, Department of Restorative Medicine of Neuro-Musculoskeletal System (Orthopaedic Surgery) Kanazawa University Graduate School of Medical Science Shimadzu Corporation
カタログの1ページ目を開く
Special Report Clinical Applications to Orthopaedics by New X-ray Technology At the 83 rd Annual Meeting of the Japanese Orthopaedic Association held between Thursday, 27 May, and Sunday, 30 May, Shimadzu co-hosted Evening Seminar on the theme of“Clinical Applications to Orthopaedics by New X-ray Technology”on 29 May. The Seminar was chaired by Akinori SAKAI, M.D., Associate Professor, Department of Orthopaedic Surgery, University of Occupational and Environmental Health. Lectures were given by Takatoshi AOKI, M.D., Associate Professor, Department of Radiology, University of Occupational...
カタログの2ページ目を開く
Special Report Clinical Applications to Orthopaedics by New X-ray Technology Based on image reconstruction for cone-beam CT, with correction for differences between rotation and parallel motion, and three-dimensional filtered back projection to remedy artifacts due to angular restrictions. /Parallel-plane scanning's Tomosynthesis data Tomosynthesis is a technology that obtains images on arbitrary parallel cross-sections through image recon- struction of multiple projected images taken by a single exposure. The image reconstruction is based on image reconstruction for cone-beam CT, with...
カタログの3ページ目を開く
Special Report Clinical Applications to Orthopaedics by New X-ray Technology 2006 Guideline for Medical Exposure (Plain Radiography) (A) Head (frontal) Tomosynthesis Tomosynthesis Entrance Radiography B/A Surface Dose Conditions (B) Rev. 3 . 80 Cervical vertebra (lateral) Knee joint Utility of Tomosynthesis and Slot Radiography to Orthopaedics Fig. 6 Comparison of 2006 Guideline for Medical Exposure (Plain Radiography) and Tomosynthesis Entrance Surface Dose Professor and Chairman, Department of Restorative Medicine of Neuro-Musculoskeletal System (Orthopaedic Surgery), Kanazawa University...
カタログの4ページ目を開く
Special Report Clinical Applications to Orthopaedics by New X-ray Technology Plain radiography Tomosynthesis Plain radiography Permits easy evaluation of the bone union and metal plate by 2D image Focusing on the bone union provides clear observations (Useful for evaluation of callus formation) Data analysis provides 3-D represen- tation but the image close to metal implant is easily affected by metal Fig. 3 Images of Proximal Femur Checking bone formation (post-operative) Plain radiography Make montage image from acetabular roof Fig. 5 Evaluation of the boundary conditions of femur...
カタログの5ページ目を開く
Special Report Clinical Applications to Orthopaedics by New X-ray Technology After corrective surgery on both legs (left), scoliosis (center, right) Fig. 10 valuation of Alignment of Lower Limbs by E Slot Radiography Utility of Slot Radiography Slot radiography offered by SONIALVISION safire can easily take seamless slot images to produce frontal or lateral images of the spine or lower extremities more rapidly than conventional CR (Fig. 9 ). At this hospital, slot radiography is mainly used to evaluate alignment of the lower limbs after artificial joint implant surgery or for scoliosis....
カタログの6ページ目を開くShimadzuのすべてのカタログと技術パンフレット
-
RADspeed Pro EDGE
5 ページ
-
UV-1900i
4 ページ
-
LCMS-9030
12 ページ
-
LCMS-8050
20 ページ
-
LCMS-8045
12 ページ
-
XRD-6100
32 ページ
-
EDX-LE
16 ページ
-
PDA-8000
16 ページ
-
AA-6200
12 ページ
-
UV-3600i Plus
20 ページ
-
SPM-9700HT
27 ページ
-
SALD-2300
20 ページ
-
IG-1000 Plus
16 ページ
-
DSC-60 Plus Series
8 ページ
-
TOC process analysis
16 ページ
-
MB140
4 ページ
-
GC Column Guidebook
48 ページ
-
ATX/ATY Series
6 ページ
-
MOC63u
2 ページ
-
MOC-120H
4 ページ
-
MOC63u
8 ページ
-
UW/UX Series
4 ページ
-
New products 1
1 ページ
-
New products
1 ページ
-
BL series
2 ページ
-
BW-K/BX-K
2 ページ
-
TX/TXB/TXC Series
8 ページ
-
HMV- 2 brochure
8 ページ
-
AutographA G - XSeries
20 ページ
-
Solutions Brochure
24 ページ
-
PSSM - 8 System
8 ページ
-
MOC-120H
4 ページ
カタログアーカイブ
-
MOC63U Flyer
2 ページ
-
ATX/ATY Series_2013
4 ページ
-
UW/UX Series
4 ページ
-
SALD-7101
16 ページ
-
MOC63U
6 ページ