

カタログの抜粋

GENERAL SPECIFICATIONS 3 BODY, MORGUE COOLER, END OPENING EXTERIOR - FRONT: 20 GA. (.91mm) TYPE 304 POLISHED STAINLESS STEEL, #4 FINISH SIDES, BACK, TOP: .032" (.81mm) STUCCO EMBOSSED ALUMINUM INTERIOR-WALLS, CEILING: .032" (.81mm) STUCCO EMBOSSED ALUMINUM DOOR: 20 GA. (.91mm) TYPE 304 STAINLESS STEEL, 2B FINISH FLOOR: 20 GA. (.91mm) TYPE 304 STAINLESS STEEL, 2B FINISH INSULATION - NOMINAL 4" (102mm) FOAMED IN PLACE POLYURETHANE INSULATION DOOR HEATERS - PERIMETER ANTI-SWEAT DEVICE, REPLACEABLE, HARDWARE - HINGES: EDGE MOUNT TYPE, CHROME PLATED, ADJUSTABLE; LATCHES: SAFEGUARD RADIAL LATCH, SURFACE MOUNT TYPE, CHROME PLATED, POSITIVE CATCH, KEYED, ROLLER STRIKE ASSEMBLY, AND INSIDE EMERGENCY RELEASE HANDLE; NAME PLATE HOLDERS: BRUSHED ALUMINUM, SIDE FEED GASKET - EXTRUDED VINYL, WELDED CORNERS, REPLACEABLE CARRIAGE & FRAME - 3 PIECE, TELESCOPING, GALVANIZED STEEL ZINC PLATED BALL BEARING ROLLERS REMOVABLE TRAY - QUANTITY 1, MT1 16 GA. (1.5mm) TYPE 304 POLISHED STAINLESS STEEL CART GUIDES -18 GA. (1.3mm) TYPE 304 STAINLESS STEEL, #4 FINISH CONDENSING UNIT -1/2 H.P. HERMETICALLY SEALED, AIR-COOLED EVAPORATING UNIT - BLOWER COIL, AUTOMATIC OFF-CYCLE DEFROST, DIGITAL TEMPERATURE CONTROLLER CAPACITY - (3) BODY WITH OPTIONAL MC2 CART SECTIONAL CONSTRUCTION SHIPPED DISASSEMBLED AVAILABLE OPTIONS: □ LIGHTING FIXTURE WITH PILOT SWITCH □ STAINLESS STEEL INTERIOR □ STAINLESS STEEL EXTERIOR □ STAINLESS STEEL TRIM ENCLOSURE PANELS □ OPPOSITE DOOR SWING □ ROLLER FRAME TRAY RAILS WITH ANTI-TILT FOR CSI/JEWETT BODY TRANSPORT SYSTEMS □ TWO-BODY MORGUE CART, MC2 WITH BODY TRAYS □ MODEL DTPM TEMPERATURE AND POWER MONITORING SYSTEM □ MODEL 7ER CIRCULAR SEVEN DAY CHART RECORDER □ OUTDOOR MOUNTED CONDENSING UNIT □ WATER COOLED CONDENSING UNIT □ CONTACT CSI/JEWETT FOR CUSTOM SPECIFICATIONS OR OPTIONS
カタログの1ページ目を開く
TELESCOPING CARRIAGE EVAPORATING UNIT MORGUE CART (OPTIONAL EXTRA) STEEL RAMP SIDE ELEVATION FRONT ELEVATION 1. (2) 115 VOLTS/60 HERTZ/1 PHASE, 15 AMP CIRCUIT FOR DOOR HEATERS, DIGITAL CONTROLLER AND EVAPORATOR, PROVIDE DISCONNECT SWITCH FOR EACH CIRCUIT, AND ALL JUNCTION BOX(ES), CONDUIT, AND FITTINGS AS REQUIRED BY STATE AND LOCAL REGULATIONS. WITHIN 5'-0" OF DESIGNATED AREA ON DRAWING. 2. (1) 208-230 VOLTS/ 60 HERTZ/1 PHASE, 20 AMP CIRCUIT FOR CONDENSING UNIT, PROVIDE DISCONNECT SWITCH FOR EACH CIRCUIT, AND ALL JUNCTION BOX(ES), CONDUIT, AND FITTINGS AS REQUIRED BY STATE AND LOCAL...
カタログの2ページ目を開くSpire Integrated Solutionsのすべてのカタログと技術パンフレット
-
CWC Series
4 ページ
-
Surgical Scrub Sinks
2 ページ
-
STERIPLUS™ 40
2 ページ
-
Tesalys
8 ページ
-
Model DPEM
2 ページ
-
Medicine Station
2 ページ
-
NSM5 Specifications
2 ページ
-
MC2-B-MT1
2 ページ
-
Model DPV
2 ページ
-
DP AUTOPSY TABLE
2 ページ
-
R1910-31L/R
2 ページ
-
SR1910-30
2 ページ
-
REMOTE MORGUE
2 ページ
-
6R2W SPECS
2 ページ
-
4R2W Specs
2 ページ
-
3R1W SUBMITTAL
1 ページ
-
2R1W SUBMITTAL
1 ページ
-
1R SUBMITTAL
1 ページ