Improved Electron Transfer Dissociation (ETD) Duty Cycle and Spectral Signal to Noise Ratio in a Dual Cell Linear Ion Trap
1 / 7ページ

カタログの抜粋

Improved Electron Transfer Dissociation (ETD) Duty Cycle and Spectral Signal to Noise Ratio in a Dual Cell Linear Ion Trap - 1

Improved Electron Transfer Dissociation (ETD) Duty Cycle and Spectral Signal to Noise Ratio in a Dual Cell Linear Ion Trap Christopher Mullen,1 Lee Earley,1 Jean-Jacques Dunyach,1 John E.P. Syka,1 Jeffrey Shabanowitz, 2 A. Michelle English, 2 Donald F. Hunt2 1 Thermo Fisher Scientific, San Jose, CA; 2 Department of Chemistry, University of Virginia, Charlottesville, VA

カタログの1ページ目を開く
Improved Electron Transfer Dissociation (ETD) Duty Cycle and Spectral Signal to Noise Ratio in a Dual Cell Linear Ion Trap - 2

Methods: Thermo Scientific™ Orbitrap Fusion™ Tribrid™ mass spectrometer with the Thermo Scientific™ EASY-ETD™ ion source. Performing the ETD reaction in cation precursor population to the reagent anion species can independent trapping (CSIT) a number of cation precursor ch function of the space charge c Figure 2 shows the potentials injection events and the relativ Purpose: Improve ETD Signal to Noise (S/N) ratio and scan duty cycle. Results: Developed a methodology incorporating multiple fills of ETD products into a storage cell followed by a single m/z analysis leading to improved...

カタログの2ページ目を開く
Improved Electron Transfer Dissociation (ETD) Duty Cycle and Spectral Signal to Noise Ratio in a Dual Cell Linear Ion Trap - 3

Motivation for Employing Multiple Fills ETD ated to be a useful tool for the with labile PTM’s, peptides with he approach is that it leads to a al, compared to conventional action and the fact that the possibility to circumvent these z analysis in a 2D linear ion trap ss resolving quadrupole, OT-LT) architecture. linear ion trap is accomplished sel, and utilizing the low is cell. In this fashion, the e number of fills requested) a single m/z analysis in either priate transfer, in the OT mass p Fusion Tribrid MS. FIGURE 2. Cation sequestration and reagent injection conditions prior to the...

カタログの3ページ目を開く
Improved Electron Transfer Dissociation (ETD) Duty Cycle and Spectral Signal to Noise Ratio in a Dual Cell Linear Ion Trap - 4

jection conditions prior to the ual cell linear trap FIGURE 4. a) Angiotensin I b and y ion formation observed at high precursor initial targets resulting from harsh sequestration conditions. b) Fragment yield versus precursor target demonstrating the onset of b and y ion formation. AngioVsTarget_ETD_50msec #548 RT: 2.58 AV: 1 NL: 6.18E5 T: FTMS + p ESI Full ms2 433.0000@etd0.01 [150.0000-1500.0000] Relative Abundance ations Held In Back Section T is determined by the axial potential ured by a number of methods. We reaction of Angiotensin I as a ragment TIC plotted as a function of ressure...

カタログの4ページ目を開く
Improved Electron Transfer Dissociation (ETD) Duty Cycle and Spectral Signal to Noise Ratio in a Dual Cell Linear Ion Trap - 5

FIGURE 6. Comparison of the Angiotensin I ETD c and z ion fragment TIC for an up to 8-fills ETD approach versus a single fill. The multiple fill data was taken at three individual precursor targets per fill corresponding to 1e4 (blue squares), 5e4 (red circles), and 1e5 (green triangles) charges/fill. erved at high precursor ditions. b) Fragment yield and y ion formation. ea vs. Precursor Target . Rxn Time = 70 msec rsor = Angio3+ zer = Orbitrap It is apparent (Figure 6) that the working range using the multiple fills approach is much greater than that for a single fill, while preserving...

カタログの5ページ目を開く
Improved Electron Transfer Dissociation (ETD) Duty Cycle and Spectral Signal to Noise Ratio in a Dual Cell Linear Ion Trap - 6

nd z ion fragment TIC for an multiple fill data was taken at ding to 1e4 (blue squares), fill. The geometry of the Orbitrap Fusion Tribrid MS in conjunction with it’s ability to run scans in a parallel/pipelined fashion affords a significant decrease in scan acquisition time per spectrum for the multiple fills approach (Figure 8) as the ETD fills are run in parallel with OT m/z analysis. FIGURE 8. Scan acquisition time per spectrum for the ETD multiple fills experiment and the uScans approach taken at a variety of Orbitrap transient durations. Scan Time per Spectrum (sec) e multiple fills...

カタログの6ページ目を開く
Improved Electron Transfer Dissociation (ETD) Duty Cycle and Spectral Signal to Noise Ratio in a Dual Cell Linear Ion Trap - 7

www.thermoscientific.com ©2014 Thermo Fisher Scientific Inc. All rights reserved. ISO is a trademark of the International Standards Organization. All other trademarks are the property of Thermo Fisher Scientific and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your...

カタログの7ページ目を開く

Thermo Scientificのすべてのカタログと技術パンフレット

  1. CryoStar NX50

    2 ページ

  2. MSC-Advantage BSC

    54 ページ

  3. Multifuge

    58 ページ

  4. Multidrop Combi nL

    4 ページ

  5. MaxQ 6000

    40 ページ

  6. Multi Tube Rotator

    13 ページ

  7. 1300 Series A2

    76 ページ

  8. CO2 Incubator Family

    28 ページ

  9. CO2 incubators

    7 ページ

  10. Varioskan™ LUX

    54 ページ

  11. Q Exactive Plus

    4 ページ

  12. LTQ XL™

    4 ページ

  13. SureTect Range

    4 ページ

  14. QuantStudio™ 3

    8 ページ

  15. Furnaces

    2 ページ

  16. native MS

    16 ページ

  17. RM 200 EG

    4 ページ

  18. Darwin LIMS

    2 ページ

  19. FBS Alternatives

    8 ページ

  20. Konelab 20

    2 ページ

  21. Indiko

    6 ページ