picoSpin Spectrometer Frequently Asked Questions

カタログの1ページ目を開く
picoSpin Spectrometer - 2

© 2013 Thermo Fisher Scientific Inc. All rights reserved.

カタログの2ページ目を開く
picoSpin Spectrometer - 3

Frequently Asked Questions General Questions Is the Thermo Scientific™ picoSpin™ 45 NMR spectrometer really the world’s first compact NMR spectrometer? Haven’t desktop NMR machines been around for years? In a proton NMR spectrum, lines are typically separated by a few parts per million (ppm). To qualify as a true spectrometer, an NMR system must have resolution well below 1 ppm. The picoSpin 45’s resolution is better than 0.06 ppm, or 60 ppb (parts per billion). Before the picoSpin 45, all commercial compact NMR machines had resolution that was too poor for them to qualify as spectrometers....

カタログの3ページ目を開く
picoSpin Spectrometer - 4

Frequently Asked Questions Sample Handling Why does the picoSpin have a capillary cartridge? For convenient replacement. When reasonable precautions are observed, problems with clogging and contamination of the capillary can be avoided. However, accidents do occur, and when they do, it is a great advantage to be able to replace the capillary in the field. Cartridge changes only take a few minutes. The unit should be reshimmed whenever the cartridge is changed. What experiments can I do other than 1-D spectroscopy? The picoSpin contains a general-purpose programmable pulse sequencer with 20...

カタログの4ページ目を開く
picoSpin Spectrometer - 5

Frequently Asked Questions Chemical Applications Chemical Applications What kind of samples can I measure? Any proton-containing liquid, not too viscous for injection into a 0.4 mm ID capillary, can be used. Will the signal I am looking for be strong enough to see? Good question! It is always a good idea to estimate the signal-to-noise ratio (SNR) before you get started with unfamiliar samples. The exact SNR depends on many things, including the magnet shim and the way data is recorded and analyzed. However, you can usually make an adequate estimate like this: The picoSpin single-scan SNR...

カタログの5ページ目を開く
picoSpin Spectrometer - 6

Frequently Asked Questions Installation Installation Where can I install a picoSpin spectrometer? There are no special facilities or environmental requirements. You can place a picoSpin spectrometer in any indoor location where a person would be comfortable; however, temperature changes must be gradual during the course of a data acquisition. AC magnetic fields generated by nearby utility power that are stronger than 1 mGauss amplitude will cause small side-bands to appear on spectra. In unusual cases where this is a problem, the unit can be oriented so that the AC field vector is...

カタログの6ページ目を開く

Thermo Scientificのすべてのカタログと技術パンフレット

  1. CryoStar NX50

    2 ページ

  2. MSC-Advantage BSC

    54 ページ

  3. Multifuge

    58 ページ

  4. Multidrop Combi nL

    4 ページ

  5. MaxQ 6000

    40 ページ

  6. Multi Tube Rotator

    13 ページ

  7. 1300 Series A2

    76 ページ

  8. CO2 Incubator Family

    28 ページ

  9. CO2 incubators

    7 ページ

  10. Varioskan™ LUX

    54 ページ

  11. Q Exactive Plus

    4 ページ

  12. LTQ XL™

    4 ページ

  13. SureTect Range

    4 ページ

  14. QuantStudio™ 3

    8 ページ

  15. Furnaces

    2 ページ

  16. native MS

    16 ページ

  17. RM 200 EG

    4 ページ

  18. Darwin LIMS

    2 ページ

  19. FBS Alternatives

    8 ページ

  20. Konelab 20

    2 ページ

  21. Indiko

    6 ページ