Catalog excerpts

BiLevel ST with Target VT Function Luna G3 BPAP 30VT The Luna G3 BPAP 30VT is a biLevel PAP device intended to provide non-invasive ventilation for patients with obstructive sleep apnea (OSA) or respiratory insufficiency. It is intended for adult patients by prescription in the home or hospital/institutional environment. With its Target Tidal Volume function, excellent comfort features and effective performance, the Luna G3 BPAP 30VT offers each patient personalized ventilation support.
Open the catalog to page 1
Efficiencies in Therapy S/T Mode The device works in conjunction with patient’s breathing. If there is no inhalation for a certain period of time, the device will give a forced ventilation to ensure the minimum ventilation. Triggered by patient inspiration. Triggered by machine if there is no patient inspiration for a certain period of time (60s/RR) or it doesn’t meet inspiratory sensitivity. Inspiratory / Expiratory Sensitivity 8 grades of I Sens and E Sens to personalize sensitivity for each patient. 8 7 6 5 4 3 2 1
Open the catalog to page 2
Target Tidal Volume Function Optimizes IPAP according to mean VT of last 5 breaths and Target VT. Height Ideal Weight (kg) Target Vt (mL) (BMI=20) (m) (8 mL/kg) IPAP increases when Patient Vt is lower than Target Vt IPAP decreases when Patient Vt is higher than Target Vt Leak Compensation Inspiratory Time Control The device detects the leaks during treatment in real time and adjusts the baseline to ensure insufficient ventilation due to a short inspiratory time. correct triggering and related functions.
Open the catalog to page 3
Innovative PUSH Water Chamber Is Simple to Use. Water can be added without removing the water chamber for ease of use. Accessories Replacement Reminder Pre-Heat The G3 series has a pre-heat feature to warm your humidifier water up for ultimate comfort. Integrated Heated Tubing with intelligent Auto Humidity Control Integrated heated tubing with intelligent Auto Humidity control allows G3 maximum moisture while ensuring rain out in the tubing is not an issue.
Open the catalog to page 4
Compliance Data Modes Replacement Part Numbers: LG31020 Luna G3 Air Filter LG34510 Luna G3 Water Chamber LG3B Luna G3 Carry Bag LG3HT Luna G3 Heated Tubing
Open the catalog to page 5All 3B Medical catalogs and technical brochures
-
Siesta Nasal Mask
2 Pages
-
React DataLink
2 Pages
-
Viva Nasal Mask
2 Pages
-
NUMA FULL FACE MASK
2 Pages
-
RioTM II Nasal Pillow Mask
2 Pages
-
Luna TravelPAP
2 Pages
-
V-Com™ Patient Information
2 Pages
-
V+ Pro Ventilator
2 Pages
-
Pulse Oximeter
2 Pages