Postpartum Hemorrhage Simulation P97 Pro-1

POSTPARTUM HEMORRHAGE SIMULATOR P97 PRO USER MANUAL

 Open the catalog to page 1
Postpartum Hemorrhage Simulation P97 Pro-2

POSTPARTUM HEMORRHAGE SIMULATOR P97 PRO | Contents

 Open the catalog to page 2
Postpartum Hemorrhage Simulation P97 Pro-3

Developed in collaboration with leading obstetricians in Germany, the Postpartum Hemorrhage (PPH) Simulator P97 PRO provides a solution for hands-on and realistic training sessions for early recognition, systematic evaluation and treatment of PPH. Severe bleeding after birth can be fatal for the new mother within hours if she is not diagnosed and treated. To improve PPH outcomes, the PPH trainer P97 PRO from 3B Scientific helps obstetric and healthcare professional teams train the timely management and care of postpartum bleeding. In addition to the stand-alone product P97 PRO (1023727), a version...

 Open the catalog to page 3
Postpartum Hemorrhage Simulation P97 Pro-4

POSTPARTUM HEMORRHAGE SIMULATOR P97 PRO SAFETY INSTRUCTIONS Please read the below safety instructions before using the P97 PRO Follow the instructions and keep in mind the warnings while using the product. Keep away from heating sources. Do not expose the product to naked flames. Avoid the use of flammable solvents near or on this product. Wear gloves at all times while using the product. Fingernails can damage the silicone parts. Do not use any attachments other than those supplied in the package. Do not wear any jewellery items. Follow the cleaning instructions after the training sessions....

 Open the catalog to page 4
Postpartum Hemorrhage Simulation P97 Pro-5

POSTPARTUM HEMORRHAGE SIMULATOR P97 PRO INSTALLING THE P97 PRO To begin your PPH training, you need to install the P97 PRO trainer; you can easily do it by following the steps given below. Add three spoons (30 grams) of powder to 3L of water. Fill the blood reservoir bag up with simulated blood and hang it on the infusion stand.* è Note: By adjusting the mixing ratio of the blood powder and water, you can fine-tune the color and viscosity. Up to 3000 ml can be added to the blood reservoir. Note: Make sure to close the valve in the upward direction before use. 2. Connect the color-coded bleeding...

 Open the catalog to page 5
Postpartum Hemorrhage Simulation P97 Pro-6

POSTPARTUM HEMORRHAGE SIMULATOR P97 PRO 5. Reach the color-coded openings at the bottom of the uterus and connect the corresponding ends of the blood delivery tubes. è Note: The tube with color code red has to be inserted few inches deep into the slot so that the vaginal rupture could be connected to it from the vaginal canal. 6. Connect the deflation bulb to the point found at the bottom end of the uterus. 7. Re-insert the abdominal foam backing and button the abdominal wall silicone piece. POSTPARTUM HEMORRHAGE SIMULATOR P97 PRO | Installing P97 PRO

 Open the catalog to page 6
Postpartum Hemorrhage Simulation P97 Pro-7

POSTPARTUM HEMORRHAGE SIMULATOR P97 PRO 8. F inally, fix the vaginal rupture insert into the dedicated spot in the vagina. Make sure that the blood delivery tube is inserted firmly into the rupture insert. Note: For a firm fixation and to avoid unwanted blood leakage, the edges of the rupture insert must be fully covered by the surrounding silicone layer. POSTPARTUM HEMORRHAGE SIMULATOR P97 PRO | Installing P97 PRO

 Open the catalog to page 7
Postpartum Hemorrhage Simulation P97 Pro-8

POSTPARTUM HEMORRHAGE SIMULATOR P97 PRO HOW TO START THE BLEEDING DELIVERY P97 PRO allows you to demonstrate 3 types of bleeding scenarios in PPH. To initiate your choice of bleeding scenario please follow the instructions below: è Note: Please observe the opening position for the blood delivery to start. 1. U terus bleeding: To start the uterus bleeding open the valve on the bleeding connector with color code – blue. 2. C ervix bleeding: To start the cervix bleeding open the valve on the bleeding connector with color code – yellow. 3. Vaginal bleeding: To start the vaginal bleeding, please incise...

 Open the catalog to page 8
Postpartum Hemorrhage Simulation P97 Pro-9

POSTPARTUM HEMORRHAGE SIMULATOR P97 PRO APPLICATION POSSIBILITIES P97 PRO is a comprehensive PPH trainer, which allows you to teach your students to diagnose and perform the treatment required to control the blood loss in a patient. Here are the various application possibilities you get using this trainer: 1. Removal of retained placenta: A placenta with three residual pieces can be placed in the uterus to train the required medical interventions like manual removal a retained placenta. 2. Fundal massage & Bi-manual compression: The student can perform fundal massage and bi-manual compression....

 Open the catalog to page 9
Postpartum Hemorrhage Simulation P97 Pro-10

POSTPARTUM HEMORRHAGE SIMULATOR P97 PRO 6. Vaginal tear suturing: You can incise any common pattern of the vaginal tear on the vaginal rupture inserts. Suturing of incisions can be trained using real tools and instruments. 7. Uterus compression suturing: You can use the 2 separate foam uterus (included in the delivery content) to train all kinds of common compression sutures. 8.Bladder catheterization (no fluids): Both silicone and PVC catheters can be used. When using Foley catheters, we recommend the size CH12 or otherwise the size CH14. Catheters with straight and rounded tips should be used....

 Open the catalog to page 10
Postpartum Hemorrhage Simulation P97 Pro-11

POSTPARTUM HEMORRHAGE SIMULATOR P97 PRO CLEANING AND CARE Cleaning P97 PRO is a simple process and we highly recommend you to follow these cleaning instructions after use: 1. W ashing the placenta: Remove any traces of blood or lubricant on the placenta and the residuals by washing them with a neutral soap and wipe them with a tissue or a cloth. 2. Draining the blood reservoir: To drain the blood reservoir, firstly make sure the blue valve is locked in an upward direction. Then disconnect the luer lock system. 3. Washing the reservoir: Remove the blood reservoir and drain it completely opening...

 Open the catalog to page 11
Postpartum Hemorrhage Simulation P97 Pro-12

After cleaning, you can easily assemble the P97 PRO trainer back to its original form by following these steps: 1. Place the simulator on a non-slip surface e.g. a table. 2. Fix the pelvic insert around the vaginal canal on the silicone piece (observe correct orientation). 3. Then pushing from above, insert the silicone piece along with the pelvic insert into the pelvis until the uterus is firmly positioned. 4. Place the abdominal wall foam backing covering the abdominal cavity 5. Bring the abdominal wall silicon piece on top of the foam and secure the silicon piece to the base. 6. Start to button...

 Open the catalog to page 12
Postpartum Hemorrhage Simulation P97 Pro-13

> CONTACT INFORMATION > TECHNICAL DATA 3B Scientific A worldwide group of companies 3B Scientific GmbH Birthing Simulator P90 PRO Birthing Simulator P90 BASIC Vaginal rupture inserts 5 pieces Foam uteri 2 pieces Placenta with 2 sets of residual pieces Placenta residual pieces 1 set Blood powder Blood Powder (set of 10) POSTPARTUM HEMORRHAGE SIMULATOR P97 PRO I Technical Data I Order List I Contact Information

 Open the catalog to page 13

All 3B Scientific catalogs and technical brochures

  1. PPH Trainer P97

    14  Pages

  2. Acupuncture

    35  Pages

  3. Best of Therapy

    12  Pages

  4. K17

    16  Pages

  5. D10

    12  Pages

  6. L56

    30  Pages

  7. L50, L51, L55

    36  Pages

  8. Female Breast

    30  Pages

  9. C41

    16  Pages

  10. C18

    9  Pages

  11. G01

    24  Pages

  12. M10

    16  Pages

  13. A291

    20  Pages

  14. F11

    13  Pages

  15. P72

    48  Pages

  16. B60

    16  Pages

  17. A05/2 ,A11, A13

    18  Pages

  18. A290 A291

    20  Pages

  19. G21, G22

    9  Pages

  20. K25

    12  Pages

  21. K20, K21

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.