ATLAS BABY THE ALS PEDIATRIC SIMULATOR P77 USER MANUAL

 Open the catalog to page 1
Product Manual Atlas Baby-2

ATLAS BABY THE ALS PEDIATRIC SIMULATOR P77 | Contents

 Open the catalog to page 2
Product Manual Atlas Baby-3

Atlas Baby is the ALS pediatric simulator by 3B Scientific used for conducting interdisciplinary and interprofessional emergency training. It offers extensive emergency-specific applications for advanced life support in simulation-based training and further training. 1. Atlas Baby Manikin 5. Umbilical Cord Stump 3 ATLAS BABY THE ALS PEDIATRIC SIMULATOR P77 | Product Introduction | Delivery Content

 Open the catalog to page 3
Product Manual Atlas Baby-4

Atlas Baby features: • Atlas Baby replicates the anatomy of the airways, complete with tongue, epiglottis, vocal cords, trachea, and esophagus. • Airway management - head-tilt/chin-lift or the Esmarch maneuvre. • Ability to clear the airway includes simulated aspiration and removing inserted foreign bodies. No fluids. • The airway of the simulator can accommodate extra-/supra-glottic airway alternatives and oral and nasal intubation. • Advanced airway, for insertion of oral airways (OPA) and nasal airways (NPA). • Intraosseous (IO) vascular access via the left tibia and distal femur. • Intravenous...

 Open the catalog to page 4
Product Manual Atlas Baby-5

ATLAS BABY THE ALS PEDIATRIC SIMULATOR P77 GENERAL HANDLING Before using Atlas Baby keep in mind these safety instructions • Wear gloves as required during simulation scenarios. • Avoid using colored plastic gloves, as they may cause discoloration. The device may only be stored and charged in dry rooms. Operating temperature: 0 °C up to +30 °C Storage temperature: -10 °C up to +40 °C Air humidity: max. 85% • To maintain Atlas Baby skin, wash hands before use and place Atlas Baby on a clean surface. • To avoid permanent staining avoid the use of ink pens, felt-tipped markers, acetone, or iodine....

 Open the catalog to page 5
Product Manual Atlas Baby-6

Atlas Baby features a color-coded indicator on the power button, which serves to display the status of its Wi-Fi connection through different colors: Atlas Baby USB-C charging port can be found behind the left ear. There is a symbol of USB-C charging on the skin. Lift up the neck skin to find the USB-C charging port. Atlas Baby is 48 cm tall, weighs 2.5 kg and comes in two different skin tones. Atlas Baby can be charged using the provided charger and can be used wirelessly during training sessions. > AIRWAY Atlas Baby replicates the anatomy of the airways, complete with tongue, epiglottis, vocal...

 Open the catalog to page 6
Product Manual Atlas Baby-7

ATLAS BABY THE ALS PEDIATRIC SIMULATOR P77 By using auscultation and checking for an excursion in the thoracic region, you can determine whether bag-mask ventilation was performed correctly and if the airway was properly cleared. Likewise incorrect right stem intubations can be confirmed when there is chest excursion and lung sound in the right side. Use auscultation to check for an excursion in the abdomen to determine esophageal intubation. Supra-glottic airway alternatives like, iGel, Laryngeal Masks (LMA) and Laryngeal Tubes (LT) can be used in accordance with manufacturers’ instructions....

 Open the catalog to page 7
Product Manual Atlas Baby-8

> CPR Atlas Baby replicates the anatomy of a rib cage and enables thoracic compressions to be carried out in accordance with the resuscitation guidelines. Thoracic compressions can be performed intermittently or continuously with bag-mask ventilation providing a realistic resistance of the chest during CPR. The CPR dashboard screen and Generic Defibrillator gives you feedback on the hand position. With the use of REALITi 360 resuscitation artifact displays on the ECG tracing, in addition to the compression rate and depth being displayed on the monitor. ✓ Compressions that generate ECG artifacts...

 Open the catalog to page 8
Product Manual Atlas Baby-9

ATLAS BABY THE ALS PEDIATRIC SIMULATOR P77 CIRCULATION Atlas Baby features an IV site for peripheral line placement on the left hand, two IO sites on the distal femur and tibia, an IM site in the vastus lateralis muscle and umbilical line catheter insertion via the umbilical line. When administering medication through the IV site, IO access sites, or IM access, connect a drain bag to the Luer lock adapter to manage fluids. Recommended puncture sizes • IV: ≤22G • IO: drilling system To change the IV arm, IO leg and IM insert, remove them from their original position and disconnect them from the...

 Open the catalog to page 9
Product Manual Atlas Baby-10

ATLAS BABY THE ALS PEDIATRIC SIMULATOR P77 NEUROLOGICAL Atlas Baby features a versatile pupillary assembly, offering three distinct eye states: normal, constricted, and dilated. Easily adjust the eyes by gently rolling open or closing the eyelids. ATLAS BABY THE ALS PEDIATRIC SIMULATOR P77 | Neurological

 Open the catalog to page 10
Product Manual Atlas Baby-11

ATLAS BABY THE ALS PEDIATRIC SIMULATOR P77 Quick Start Guide Thank you for purchasing Atlas Baby – the pediatric ALS Simulator Connecting Atlas Baby with REALITi 360: A Simple Guide Scenario 1: Your existing Wi-Fi router is called iSimulate-5.0 1. Power Up: Start by turning on your iSimulate-5.0 router. 2. Wi-Fi Connection: Ensure both the REALITi Monitor iPad and the Control iPad are connected to the iSimulate-5.0 network. WiFi Name: iSimulate-5.0 Password: iSimulate2012 3. Turn On Atlas Baby: Locate and press the power button on the back of the manikin. This will automatically connect it to...

 Open the catalog to page 11
Product Manual Atlas Baby-12

4. Launch REALITi App: Open the REALITi app on both iPads, selecting ‘Staging’ on the Monitor and ‘Control’ on the Control iPad. Welcome to REALITi Control 5. Connect iPads: Use the ‘Tap to Connect’ feature on the Control iPad to link both devices. If the Monitor iPad does not appear in the list, check that the Staging iPad and the Monitor iPad are both connected to the Wi-Fi network of your REALITi router: iSimulate-5.0 (both iPads must be on the same Wi-Fi network). Get started by tapping the connection bar Please make sure there is a monitor runnino--V- 6. Choose and Start a Scenario: From...

 Open the catalog to page 12
Product Manual Atlas Baby-13

ATLAS BABY THE ALS PEDIATRIC SIMULATOR P77 8. On the Monitor iPad, the scenario or monitor selected from step 7 should appear. Start the defibrillator. 9. Scan for Atlas Baby: Swipe in from the right screen edge of the Monitor iPad and tap “Rescan Devices” to show the “Available Devices”. 10. From the available devices select ‘Atlas Baby’ by tapping ‘Connect Device’. The connected Atlas Baby will be calibrated automatically. 11. Commence Simulation: Compress the manikin. You will be able to see the CPR compression in the ECG waveform and the bar graph. Scenario 2: Your existing Wi-Fi router is...

 Open the catalog to page 13

All 3B Scientific catalogs and technical brochures

  1. PPH Trainer P97

    14  Pages

  2. Acupuncture

    35  Pages

  3. Best of Therapy

    12  Pages

  4. K17

    16  Pages

  5. D10

    12  Pages

  6. L56

    30  Pages

  7. L50, L51, L55

    36  Pages

  8. Female Breast

    30  Pages

  9. C41

    16  Pages

  10. C18

    9  Pages

  11. G01

    24  Pages

  12. M10

    16  Pages

  13. A291

    20  Pages

  14. F11

    13  Pages

  15. P72

    48  Pages

  16. B60

    16  Pages

  17. A05/2 ,A11, A13

    18  Pages

  18. A290 A291

    20  Pages

  19. G21, G22

    9  Pages

  20. K25

    12  Pages

  21. K20, K21

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.