M°de Select QUICKLUNG BREATHER user manual 1025192, 1025193
Open the catalog to page 1QUICKLUNG BREATH
Open the catalog to page 2QUICKLUNG BREATHER 1. ABOUT THE USER’S MANUAL This User’s Manual is for IngMar Medical’s QuickLung Breather, the Spontaneous Breathing Accessory for the QuickLung Precision Test Lung. It is recommended that you read this instruction manual carefully before using the QuickLung Breather. This manual is divided into several main sections to help you easily access information and instructions you need. 1.1 Conventions Used in This Manual ! WARNING! Indicates a potentially harmful condition that can lead to personal injury. CAUTION! Indicates a condition that may lead to equipment damage or malfunction....
Open the catalog to page 3• Electrical Supply: Connect the power supply provided only to a properly grounded wall outlet providing 100 - 240 V AC, 50 - 60 Hz. • Do not operate QuickLung Breather when it is wet due to spills or condensation. Never sterilize or immerse the device in liquids. • Always use dry air or oxygen with the QuickLung. “Rainout” inside the bellows of the QuickLung may impair its function and may eventually cause damage. • Do not operate the QuickLung Breather if it appears to have been dropped or damaged. Fire Hazards related to the use of oxygen: When using the system with elevated concentrations...
Open the catalog to page 4QUICKLUNG BREATHER 4. ASL QUICKLUNG BREATHER SETUP 4.1 Installing the QuickLung Before attempting to install the QuickLung, ensure that the lift arms on the side of the QuickLung breather are in a downward position. Make sure that the downward position of the lift arms is not beyond the marking indicated on the side of the QuickLung Breather chassis. è If you already own a QuickLung that does not have the side rails or the “wing” panel installed, please contact IngMar Medical to obtain the correct part. On the rear of the Breather, there is a spring-loaded pin used to secure the QuickLung test...
Open the catalog to page 5QUICKLUNG BREATHER 5. RUNNING A SIMULATION After safely making the electrical connections and installing the QuickLung, you are now ready to run your first simulation. To begin, turn on the system: 1. Flip the power switch at the back of the QuickLung Breather to the ON ( | )position. Figure 5.1: Turning On the Device On the front panel, the LCD display will light up and show the QuickLung Settings window. 2. Using the left <+/-> buttons on the front panel, set the QL Model to Adult or Junior, matching the actual QuickLung that is installed on the QuickLung Breather. 3. Using the right <+/->...
Open the catalog to page 6QUICKLUNG BREATHER 6. When complete, press Mode Select to cycle through and select one of the pre-defined breath patterns. Use the <+/-> to adjust the settings of each pattern. 7. Press Start/Stop to start a simulation with the preselected mode and settings of that mode. 8. The symbol then turns into, to indicate the system is running. è All settings for a particular breath pattern are retained when you switch to a different mode and will be effective again when the original mode is chosen. The basic patterns available are depicted in the Figure below. For details on using the different modes...
Open the catalog to page 7The following section describes the different breathing patterns available in the QuickLung Breather, together with the respective ranges of breath rate, I:E-ratio, flow rate, and the maximum spontaneous tidal volume possible. Vt indicated in this context is representative only for applications where no PEEP is present that would require the Offset to be adjusted, diminishing the maximum available tidal volume. Generally, high Resistance settings and small Compliance settings limit the range of flow and volume. R = 5 cm H2O R = 20 cm H2O R = 50 cm H2O C = 50 ml/cm H2O C = 20 ml/cm H2O C = 10...
Open the catalog to page 8“Kussmaul breathing is a deep and labored breathing pattern often associated with severe metabolic acidosis, particularly diabetic ketoacidosis (DKA) but also kidney failure. It is a form of hyperventilation, which is any breathing pattern that reduces carbon dioxide in the blood due to increased rate or depth of respiration.” [3] The range of parameters that are available is depicted in the table below: EUPNEA Rate [BPM] Volume [ml] I:E ratio [%] MV [L] Insp. Hold [%] 6.6 Using the Apnea Feature You can control how apnea enters into the breathing patterns of your simulated patient by selecting...
Open the catalog to page 9When inquiring about maintenance, always have the serial number of your device available. Additional reference information can be found on the label on the bottom of the instrument a copy of which is included also in the product binder supplied which each instrument. The QuickLung Breather does not contain user-serviceable components or parts. Unauthorized opening of the device will void the warranty. 8.1 Performance Specifications Volumes Total Volume (QuickLung) 1.2 L (400 ml for Junior) Spontaneous Tidal Volume 0 to 720 ml (0 to 215 ml for Junior) Spontaneous Breath Rate 4 to 60 BPM based...
Open the catalog to page 10QUICKLUNG BREATHER 9. LEGAL INFORMATION Product Warranty Educational tools and test instruments manufactured or distributed by IngMar Medical come with a limited warranty, covering materials and workmanship, for a period of one year from the date of shipment, except for products with stated warranties other than one year. Software, fuses and batteries are excluded from this warranty. System components such as computers are supplied with the factory warranty of the original manufacturer. IngMar Medical reserves the right to perform warranty service(s) at its factory, at an authorized repair center,...
Open the catalog to page 11> 10. REPLACEMENT PARTS > QUICKLUNG BREATHER QuickTrigger Module QuickLung Swivel Elbow QuickLung Standard Elbow Adapter QuickLung Protective Case QuickLung Spring Replacement Kit QuickLung Spring Holder QuickLung Rubber Feet 025219 QuickLung Breather System for Adult Patients 025202 QuickLung Breather System for Pediatric Patients 025201 QuickLung Precision Test Lung, pediatric 025206 QuickLung Precision Test Lung, adult 025203 QuickLung® Breather Option A worldwide group of companies 3B Scientific GmbH © Copyright 2024 for instruction manual and design of product: 3B Scientific GmbH, Germany...
Open the catalog to page 129 Pages
4 Pages
4 Pages
3 Pages
3 Pages
3 Pages
2 Pages
2 Pages
14 Pages
3 Pages
2 Pages
2 Pages
16 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
13 Pages
51 Pages
16 Pages
18 Pages
23 Pages
35 Pages
12 Pages
60 Pages
11 Pages
2 Pages
9 Pages
196 Pages
16 Pages
13 Pages
12 Pages
12 Pages
30 Pages
36 Pages
12 Pages
52 Pages
16 Pages
12 Pages
2 Pages
8 Pages
2 Pages
16 Pages
28 Pages
2 Pages
30 Pages
16 Pages
9 Pages
24 Pages
3 Pages
16 Pages
20 Pages
13 Pages
48 Pages
16 Pages
18 Pages
20 Pages
9 Pages
12 Pages
12 Pages