Model 1800 - 1

Microelectrode AC Amplifier A-M SYSTEMS The Model 1800 AC Microelectrode Amplifier is a two-channel, differential amplifier configured for use with headstage probes. The instrument is intended for extracellular recording and/or stimulating in conjunction with high impedance metal microelectrodes. Ideal for single-cell spike recordings, it can also be used in a number of research or teaching applications requiring extracellular neurophysiological recording from excitable tissue such as nerve, muscle (EMG), EEG, EKG, and ERG recordings. Each channel of the Model 1800 contains a high-gain, low-noise differential amplifier stage followed by low-frequency, high-frequency, and notch filters. Three operating modes are available to accomodate recording, stimulating, and verification of electrode impedance. Multiple gain settings and simultaneous current measurements during stimulation are provided. An internally calibrated current source allows in situ verification of electrode impedance. The Model 1800 Headstage includes a mounting rod and bracket for a standard micromanipulator and a complete set of miniature electrode cables. Common applications for the Model 1800 Microelectrode AC Amplifier include, but are not limited to: ° Single Cell Action Potentials ° Multiple-Unit Recordings o EEG / EMG / EKG / ERG recordings o Long-term Potentiation o Evoked Potentials o Waveform Sorting The Model 1800 Microelectrode AC Amplifier is designed for research grade recording quality, with a straightforward interface that also makes it ideal for teaching applications. • Can record from or stimulate through electrodes without changing connections • Fixed Gain: x100, x1000, or x10,000 • Low noise • Notch filter for power line frequency • In situ electrode impedance measurement • Current monitor during stimulation • Includes rack mount hardware

Open the catalog to page 1
Model 1800 - 2

Application Notes: 1) recording EEG and spikes simultaneously The Model 1800 Microelectrode AC Amplifier was designed to record from two different electrodes simultaneously. Recently, many users have requested the ability to record both spikes and EEG/Evoked potentials from the same electrode simultaneously. A-M Systems can modify the Model 1800 circuitry to accomplish this task. The output from the Channel 1 headstage is routed internally to the input to the Channel 2 circuitry. The same signal can then be filtered at different settings by the Channel 1 and 2 filter stages. Contact A-M...

Open the catalog to page 2

All A-M Systems catalogs and technical brochures

  1. Model 3300

    2 Pages

  2. Model 3600

    2 Pages

  3. Model 3000

    2 Pages

  4. Model 2400

    2 Pages

  5. Model 4000

    2 Pages

  6. Model 3500

    2 Pages

  7. Model 1700

    2 Pages

  8. MODEL 3100

    2 Pages

  9. Model 1600

    2 Pages

  10. Model 3300

    2 Pages

  11. Model 3800

    2 Pages

  12. Model 2100

    2 Pages

  13. Model 4100

    2 Pages