Overview: The Fume Hood Scrubber Model ACM-1712S is designed for effective air pollution control in laboratory environments, specifically targeting water-soluble chemicals in exhaust fumes. It ensures operator safety and minimizes the risk of accidental fires.
Specifications: The fume hood is constructed from industrial-grade fire-resistant materials, including epoxy-coated wooden boards or corrosion-resistant steel. The work table is made from stainless steel (SS-304 grade) or acid-proof glazed tiles. It features a sliding sash with shatterproof glass and a counterweight mechanism.
Performance: The scrubber maintains a constant exhaust volume and minimizes static pressure loss. It operates at noise levels below 60 dB and provides illumination of up to 800 lux on the work table. The exhaust system includes FRP ducting and a heavy-duty motor with centrifugal impellers.
Features: Key features include energy efficiency, transparent doors, flexible monitoring, and compliance with NSF and NABL standards. The design is ergonomic, portable, and CE marked.
Technical Matrix: The fume hood includes a three-step air flow speed controller, centrifugal blower assembly, and operates on 220-230 volts at 50Hz. Power requirements range from 500 to 750 watts, depending on the model.
Models and Dimensions: Available models include ACM-Cafh-1200 (4’ x 2’ x 2’), ACM-Cafh-1503 (5’ x 2.5’ x 2.5’), and ACM-Cafh-1803 (6’ x 3’ x 3’).
Contact Information: Sales offices are located in Hong Kong, Russia, and India, with contact details provided for each location.
See more

Catalog excerpts

Fume Hood Scrubber (ACM-1712S)-2

FUME HOOD SCRUBBER A Fume Hood Scrubber provides excellent air pollution control for water soluble chemicals present in the laboratory fume hood exhaust fumes. These fume hoods are designed to save space and provide effective air pollution control and operator safety protection for fume hoods. Fume hood scrubber are developed and designed to be used as semi conductor ventilated enclosures so as to protect the user from harmful and toxic fumes and vapors and to eliminate the possibility of accidental fire which may lead to emission of inflammable gases during the course of experiments. Hence,...

 Open the catalog to page 2
Fume Hood Scrubber (ACM-1712S)-3

VOLUME OF EXHAUST It is generally known that fume hoods are capable of maintaining a constant exhaust volume. TESTING PROCEDURES OF CONTAINMENT Fume hood scrubber are specifically to decrease the loss of static pressure at a given baffle opening position. According to the standard procedures the average loss of static pressure at any given four points at ninety degree and 3 duct dia from the fume hood, that will not exceed 75 feet per minute at 0.25 inch, with full slash opening and face velocity of 100 feet per minute. NOISE AND SOUND LEVELS Fume hood scrubber are designed with lower noise levels...

 Open the catalog to page 3
Fume Hood Scrubber (ACM-1712S)-4

ILLUMINATION LEVELS AT WORK SPACE Our automatic fume hoods make sure that a maximum of 800 lux light is available on the work table through diffuser fluorescent light arrangement. EXHAUST ASSEMBLY These fume hood scrubber are incorporated with an extremely durable and strong exhaust system that generally persists a range of 500-1250 CM. These exhaust assembly comprises of balanced centrifugal impellers that are combined with a heavy duty three phase motor of Crompton greaves. EXHAUST DUCTING These fume hood scrubber are also integrated with a FRP ducting of required dimension as per the requirements...

 Open the catalog to page 4
Fume Hood Scrubber (ACM-1712S)-5

FEATURES § Reliable durable § Energy efficient § Ventilation across the cabinet § Transparent doors for clear view § Energy efficient & Light weight § Ventilation across the cabinet § Transparent doors for clear view § Integrated with a FRP ducting § Flexible monitoring § Flawless performance § NSF & NABL certified § Economical & Ergonomic design § Double wall construction § Portable § Assembled & fully tested § CE marked

 Open the catalog to page 5
Fume Hood Scrubber (ACM-1712S)-6

TECHNICAL MATRIX: FUME HOOD SCRUBBER Industrial grade mica clad wooden board/ steel Stainless steel sheet table of ss-304 grade/ fortified acid proof glazed tiles Stainless steel sink with tap Epoxy coating/ FRP lined Three step air flow speed controller Blower assembly Centrifugal lubricated bearing type ISI marked assembly Fluorescent light illumination greater than 800 lux on work table Noise level Noise level less than 60 db

 Open the catalog to page 6
Fume Hood Scrubber (ACM-1712S)-7

Power requirements 500 watts -750 watts( model specific) Internal work space Nominal voltage 220- 230 volts, 50Hz single phase WEIBER FUME HOOD SCRUBBER Model no Dimension (length x depth x height)

 Open the catalog to page 7
Fume Hood Scrubber (ACM-1712S)-8

An ISO 9001 : 2208 | ISO 14001 : 2008 | ISO 13485 WHO: GMP Products | GLP Compliant Products www.acmasindia.com | www.cleanroom-equipments.com | www.test-chambers.com SALES OFFICE (INDIA) Office no. 506 & 507, 5th Floor, Plot no.- C-9, Pearls Best Height-II, Netaji Subhash Place, Pitam Pura, Delhi- 110034 Land Line No.: +91 - 11- 47619688, Fax: +91-11-47619788 E-mail.: [email protected] SALES OFFICE (HONG KONG) Unit D 28 11/F Wing Tat Comm,Bidg 97, Bonham Strand East, Sheung Wan, Hong Kong (PRC) Tel.: 0086-13929598046 0086- 18922303099 E-mail.: [email protected] SHOWROOM J-284 Sector 1 Bawana...