Catalog excerpts
Monitoring System Available for Neonatal Blood Testing Screening for neonatal hypoglycemia has become a routine clinical practice. Neonatal hypoglycemia, if untreated, may result in neurological damage.1 However, most portable blood glucose monitoring products on the market do not give accurate neonatal blood glucose readings due to different limiting factors associated with neonatal blood. Major factors include: • High hematocrit levels (51-65%) in the neonatal blood.2,3 • Low glucose concentrations (20 - 80 mg/dL) in the neonatal blood.3 The On Call®Advanced Blood Glucose Monitoring System can test blood at 20-70% hematocrit using advanced Hematocrit auto-correction technology, for healthy In addition, the On Call Advanced Blood Glucose Monitoring System can also be used by anemic people and pregnant women. • Anemic people may have levels of hematocrit < 33%. Common reasons are loss of blood and nutritional • Pregnant women are at high risk of anemia because the growing fetus creates a high demand for iron. 1. Anderson, J.M., Milner, R.D.G., Strich, S.J., Effects of neonatal hypoglycemia on the nervous system. J Neurol Neurosurg Psychiatry (1967) 2. Johnson, TR. Chapter 4. Some effects of growth and development on pediatric clinical chemistry. In Pediatric Clinical Chemistry, 2nd Edition, S. Meites, Editor, AACC, 1981, p.33. 3. Kaplan, LA. Glucose. In Methods in Clinical Chemistry, Pesce, A. J. and Kaplan, L.A. CV. Mosby Co., Publishers, 1987, P.111 (Column 2, Reference Ranges). Diabetes Care Monitoring System Extensive clinical studies proved the accuracy of the On Call® Advanced Blood Glucose Monitoring System with fresh capillary, venous and neonatal blood. Fingertip Blood Testing YSI Reference Blood Glucose - Plasma (mg/dL) Neonatal Blood Testing YSI Reference Blood Glucose - Plasma (mg/dL) Venous Blood Testi YSI Reference Blood Glucose - Plasma (mg/dL) Error Grid Analysis Clinical Trial - Strip Lot B (Fingertip Capillary Blood, by Technician) ACON On Calf Advanced Blood Glucose Monitoring System vs. YSI Diabetes Care Monitoring System • Worry-free from touching blood and/or needle • Strip ejector allows easy and smooth strip disposal • Lancet ejector designed for convenient lancet release • Individually foil wrapped test strips available for more convenience and ensured high accuracy ° Simple and Quick Testing with Tiny Blood Sample • Multiple testing sites including fingertip, palm and forearm • Code chip allows for automatic calibration • Just two steps of operation • End-fill strips with wicking action make blood application as easy as a simple touch of the strip to the sample • Accurate results available in just 5 seconds • Only 0.8 IJL blood sample needed Diabetes Care
Open the catalog to page 1All Acon Diabetes Care International catalogs and technical brochures
-
OCV HCP
2 Pages
-
OCV OTC
2 Pages
-
OCS HCP
2 Pages
-
OC Redi Distributor
2 Pages
-
OCGK HCP
6 Pages
-
OCXT HCP
4 Pages
-
OCS OTC
2 Pages
-
OCP HCP
2 Pages
-
OC Redi OTC
2 Pages
-
On Call Plus II HCP
2 Pages
-
On Call Plus II OTC
2 Pages
-
OCP OTC
2 Pages
-
OCPL HCP
2 Pages
-
OCPL OTC
2 Pages
-
OCEZ II OTC
2 Pages
-
OCC HCP
2 Pages
-
OCC OTC
2 Pages
-
OCA HCP
2 Pages
-
OCA OTC
2 Pages
-
On_Call_Vivid_Pal OTC
2 Pages
-
Vivid_Pal HCP
2 Pages
-
Plus II
2 Pages
-
GK Dual
6 Pages
-
EZ II
2 Pages