OCC HCP - 1

Blood Glucose Monitoring System Blood Glucose Monitoring System Specifications Measurement Range Result Calibration Fresh whole blood (Capillary and Neonatal) Minimum Sample Size Test Time On/Off Source Battery Life Minimum of 3,000 measurements (without considering data transfer and test reminder alarm) Glucose Units of Measure The meter is pre-set to either millimoles per deciliter (mg/dL) or milligrams per liter (mmol/L) depending on the standard of your country Memory Storage Up to 300 results with time and date Automatic Shutoff 2 minutes after last action Meter Size Display Size 66g (with battery installed) Operating Temperature Operating Relative Humidity Data Port 9600 baud, 8 data bits, 1 stop bit, no parity Hematocrit Range Product Name On Call ® Chosen Blood Glucose Monitoring System 1 Meter 1 Lancing Device 1 Warranty Card 10 Test Strips 1 Manual 1 Control Solution 1 1 Carrying Case 1 Clear Cap (for testing on forearm and palm) 10 Lancets 1 Quick Reference Guide 1 Lancing Device 1 Quick Reference Guide 1 Warranty Card 1 Carrying Case 1 Clear Cap (for testing on forearm and palm) On Call® Chosen Blood Glucose Meter 1 Lancing Device 1 Carrying Case 1 Clear Cap (for testing on forearm and palm) 1 Control Solution 1 1 Quick Reference Guide 1 Warranty Card 1 Control Solution 1 1 Quick Reference Guide 1 Warranty Card 1 Manual 1 Clear Cap (for testing on forearm and palm) On Call ® Chosen Test Strips 25 Test Strips (Individually Foil Wrapped) On Call ® Lancing Device On Call® Chosen Glucose Control Solution 1 Control Solution 0 (2 ml/bottle) 1 Package Insert 1 Control Solution 1 (2 ml/bottle) 1 Control Solution 2 (2 ml/bottle) On Call® Diabetes Management Software Kit 1 USB Data Transfer Cable V CE Marked for sale in the European Community C€ A CON Laboratories, Inc., 10125 Mesa Rim Road, San Diego, CA 92121, U.S.A. Tel: 1-858-875-8000 Fax: 1-858-200-0729 E-mail: info@aconlabs.com Please visit our website for details: www.acondiabetescare.com Enhanced Accuracy with Hematocrit Auto-correction Technology DN:1150653703 ©2014 ACON Laboratories, Inc.

Open the catalog to page 1
OCC HCP - 2

Blood Glucose Monitoring System Fast and Reliable Results ® Easy 2 step operation ® Accurate results in just 5 seconds * Tiny blood sample (0.8 pL) * Clinically proven accuracy Enhanced Accuracy with Hematocrit Auto-correction Technology Advanced HCT auto-correction technology is applied to the On Call® Chosen Blood Glucose Monitoring System, which allows it to be able to test blood with very high (70%) and very low (20%) hematocrit levels including neonatal blood* and anemic blood*. Extensive clinical studies prove the accuracy of On Call®Chosen Blood Glucose Monitoring System with fresh...

Open the catalog to page 2

All ACON DIABETES CARE catalogs and technical brochures

  1. Cholesterol

    4 Pages

  2. OCR_OTC

    2 Pages

  3. OCPL_HCP

    2 Pages

  4. OCPL_OTC

    2 Pages

  5. OCC OTC

    2 Pages