AR331 THE HUNGRY MANIKIN® - PAEDIATRIC NASOGASTRIC FEEDING TRAINER Instruction Manual

Open the catalog to page 1
AR331 - 2

Thank you for purchasing this AR331 Hungry Manikin®. This manikin was designed by nutrition nurses at Birmingham Children’s Hospital to demonstrate to parents/carers the technique for inserting nasogastric and gastrostomy devices in children. The Hungry Manikin® has been significantly improved so that liquids can be introduced into the stomach. The transparent manikin cover is now removable and, by means of a simple connector, the stomach can be removed for cleaning. This simple to use simulator helps identify the stages of placement, ensuring that the nasogastric device is passed safely...

Open the catalog to page 2
AR331 - 3

Safety and Precautions Do not lie the manikin completely flat - liquids may run back up the oesophagus and leak. Always attach the foam head support first. During use, fill the stomach only to the maximum line as indicated on the manikin. Filling above this line will cause the stomach to leak. Do not store the stomach with any liquids inside, especially acidic liquids. Prolonged contact with acidic liquids will cause accelerated wear. The stomach is a disposable item and will need to be replaced periodically. This manikin is designed to facilitate training in the passing of nasogastric...

Open the catalog to page 3
AR331 - 5

S331/16 FOAM HEAD SUPPORT Transparent, removable manikin cover Rear base Simulated gastrostomy opening S331/8 REMOVABLE, REPLACEABLE STOMACH Stomach quick release connector Epiglottis cord Supplied With S331/1 RIGID CARRYING CASE If you require replacement parts please contact our Sales Department, quoting codes where applicable. Scan the QR code to access the product video. https://youtu.be/xjqXZhbaWIs 5

Open the catalog to page 5
AR331 - 7

Positioning the Foam Head Support Ensure the work area is clean and dry. The manikin may be used upright or lying down on a stable, flat surface. To position the foam head support, align the flat side to the top of the head on the rear of the white base, and push it in firmly. Do not lie the manikin down without the foam head support in position as liquids may run back up the oesophagus and cause leakage. This simulator is designed to facilitate training in the passing of nasogastric tubes and gastrostomy tube insertion. The procedures demonstrated in this manual serve as a guide only....

Open the catalog to page 7
AR331 - 8

During Use: Nasogastric Procedures 3a

Open the catalog to page 8
AR331 - 9

Using the Moveable Epiglottis to Simulate Swallowing 3a During insertion of a nasogastric tube, pull the epiglottis cord to open the epiglottis which simulates movement of the epiglottis during swallowing. Pull the epiglottis cord forward, stopping when the white stopper is visible. Continue to feed the nasogastric tube down the oesophagus and into the stomach, repeating the simulated epiglottis movement as 3a above. Do not pull excessively on the epiglottis cord as this may cause damage to the manikin. Size 8 Fr Nasogastric and Size 12 Fg Ryles tubes should be used. During use, a range of...

Open the catalog to page 9
AR331 - 10

During Use: Gastrostomy Procedures 6a

Open the catalog to page 10
AR331 - 11

Insertion of Gastrostomy Devices A gastrostomy device is not supplied with this manikin as choice of device varies according to local policy. A range of gastrostomy procedures may be simulated using the manikin. Gastrostomy devices up to size 14 Fr may be inserted into the stomach via the simulated gastrostomy opening. Liquids can then be introduced into the stomach. If required, lubricate the device with water before insertion. This manikin can accept gastrostomy devices equipped with inflatable balloons. Liquids may be introduced into the stomach via a gastrostomy device. The stomach...

Open the catalog to page 11
AR331 - 13

Remove Devices and Empty Liquid from the Stomach 8a After use, remove all nasogastric and gastrostomy devices from the manikin as well as nasal bridles and tape if used. Hold and support the manikin face down over a sink or container to empty liquid from the stomach. Cleaning and Replacing the Stomach The stomach must be cleaned and dried after each use and before storage. Do not store the stomach with any liquids inside, especially acidic liquids. Prolonged contact with acidic liquids will cause accelerated wear. To maintain optimal performance of the manikin, the stomach will need to be...

Open the catalog to page 13
AR331 - 15

Cleaning and Replacing the Stomach (Continued) 9e To remove the stomach, hold it with one hand and press the grey button on the quick release stomach connector, located in-between the lungs. Keeping the button depressed, gently pull the stomach down and slightly upwards to remove it from the base. The stomach may now be cleaned using warm water only or Milton Sterilising Fluid. Do not use soap, detergents or any other chemical cleaners to clean the stomach. To replace the clean stomach, or fit a new stomach, make sure the gastrostomy opening is facing up and the stomach connector is on the...

Open the catalog to page 15
AR331 - 17

Cleaning and Replacing the Stomach (Continued) 9j Once the stomach has been fitted, replace the transparent manikin cover by aligning it with the base and push into place. The manikin is now ready for storage or use. Remember to make sure that the epiglottis cord and simulated gastrostomy opening fit neatly through the transparent manikin cover. Cleaning the Transparent Manikin Cover and Base 10a The transparent manikin cover may be wiped with a soft sponge using a mild detergent solution.

Open the catalog to page 17
AR331 - 19

Using the Supplied Rigid Carrying Case 11a After use, or before transportation, the manikin should be placed in the supplied Rigid Carrying Case. The manikin must be placed back into the case as supplied, on its base with the foam head support placed flat side up, with the vertical support down alongside the manikin’s face. Do not store or transport the manikin with liquid inside. Store the manikin in a dry place. Do not store the manikin near heat or where it may experience extremes in temperature and humidity.

Open the catalog to page 19
AR331 - 20

2 Year Guarantee All products manufactured by Adam,Rouilly are covered by our full 2 Year Guarantee. This guarantee applies to models which have been used correctly and covers durability and functionality. As part of our policy of continual product development, the specification of products may alter without prior notice. Adam,Rouilly has over 100 year’s experience in providing quality medical models and simulators. Should you require any further information please contact our Sales Department who will be pleased to help with your enquiry. Adam,Rouilly Limited Castle Road Eurolink Business...