1. Catalogs
  2. Addfield Environmental Systems
  3. Addfield GM500 Medical Waste Incinerator Datasheet

Addfield GM500 Medical Waste Incinerator Datasheet

Addfield GM500 Medical Waste Incinerator Datasheet

Addfield GM500 Medical Waste Incinerator Datasheet

Product catalog summary
Overview: The GM500 is a top-loading incinerator designed for the secure disposal of various types of medical waste, including sharps, clinical, and pathological waste. It is manufactured by Addfield Environmental Systems Ltd., known for its high-quality incineration solutions.
Specifications: The incinerator has external dimensions of 3725 x 2570 x 1940/3825 mm and an internal chamber volume of 0.74 m³. It weighs approximately 3.5 tonnes and has a maximum load capacity of 500 kg. The nominal burn rate is less than 50 kg/hr for the UK and 50-75 kg/hr for export. It operates on a power supply of 220-250V and supports diesel, LPG, and natural gas as fuel types.
Construction and Efficiency: The GM500 features a multi-layered 180mm brick refractory for optimal heat retention and efficiency, making it up to 40% more efficient than other machines. It is suitable for smaller hospitals and clinical practices, with a focus on fuel and cost savings.
Waste Types: The incinerator can handle clinical, treated, anatomical, cytotoxic, cytostatic, offensive/hygiene, medicinal, and domestic waste.
Chamber Features: The primary chamber includes a pre-cast block impact zone, heavily insulated refractory lining, and a top-loading counterbalanced lid. The secondary chamber features a temperature-controlled burnout burner and integrated combustion burner air fans.
Control System: The Addfield PLC Controller offers a simple operational process with a touch screen HMI interface, independent burner control, and data-logging capabilities. It includes features like temperature indication, plant status indicators, and an emergency stop button.
Additional Equipment: Optional equipment includes a bin tipper for hands-free loading, a fuel tank for safe storage, and a Venturi system for advanced flue gas treatment.
Certifications: The GM500 is ISO9001:2015 and ISO14001:2015 certified, ensuring quality and environmental management standards.
See more

Catalog excerpts

Addfield GM500 Medical Waste Incinerator Datasheet-1

Secure and reliable general medical (GM) waste incineration. Fuel efficeint top loading incinerator for secure disposal of sharps, general medical, clinical, and pathological waste. Primary Chamber QUALITY ASSURED FIRM QUALITY ASSURED FIRM The GM500 is highly flexible incinerator. Designed for complete destruction of general medical waste. Manufactured to deliver optimum results through retaining maximum heat within the main chamber. Constructed with a multi layered 180mm brick refractory placing our machines at the forefront of quality. The GM500 has a 0.74m³ chamber volume, making it ideal for smaller hospitals and clinical practices. Utilising pulse firing burners, our GM range of incinerators are up to 40% more efficient than other machines, saving fuel and money. This machine perfect for laboratories and research/clinical centres. Machine Specification External L x W x H (mm) Weight (approx tonnes) Nominal Burn Rate UK* (kg/hr) Burn Rate [Export Only]* (kg/hr) Secondary Chamber • Fully insulated internal refractory lining. Constructed from high grade low thermal mass insulation. • Temperature controlled Secondary chamber burnout burner with automatic on-off control, complete with internal air fans. • Integrated combustion burner air fans automatically controlling distribution to designated areas. • Temperature sensor mounting point at the top of the chamber, ensuring the chamber reaches the required 1100°C minimum, with a 2 second retention time. Waste Type • Pre-cast block impact zone protecting refractory lining during loading. • Heavily insulated internal brick refractory, constructed along an interlocking systems to ensure maximum strength and resilience. • Premium grade high alumina content refractory brick work delivering optimal thermal retention. • Top loading counter balanced insulated access lid. • Temperature controlled waste ignition burner automatic on-off, complete with internal air fans. Door Aperture Control Panel Clinical Waste Treated Waste Fuel Types Anatomical Waste Insulation Board Cytotoxic & Cytostatic Waste Insulation Fire Brick Fire Brick (Alumina) Offensive/Hygiene Waste *We reserve the right to change the specification, dimensions and quality of materials from time to time, so long as the alteration is minor or an improvement to the said product. Medicinal Waste Domestic (municipal) Waste Addfield Environmental Systems Limited Unit 9 | Zone 4 | Burntwood Business Park Staffordshire | WS7 3XD | United Kingdom © Addfield Environmental Systems Ltd. All information should be used as a guide only, specifications ar

 Open the catalog to page 1
Addfield GM500 Medical Waste Incinerator Datasheet-2

Secure and reliable general medical (GM) waste incineration. Waste Loading and De-Ashing The GM range of incinerators are designed for top loading directly into the primary chamber. Loading can be manual or mechanically through digger or hydraulic bin tippler. To be loaded no more than once per day prior to operation. The incineration process will reduce the waste to approximately 3% volume, ash. The ash should be removed before the following waste is loaded to ensure optimum burn rates. Optional de-ashing doors are available. The Addfield Difference • Pre-Fabricated 8mm & 10mm robust mild steel...

 Open the catalog to page 2
Addfield GM500 Medical Waste Incinerator Datasheet-3

www.addfield.com Control Panel Addfield Intelligent PLC Controller Simple to operate adaptive control system for achieving optimal results from your machine. QUALITY ASSURED FIRM QUALITY ASSURED FIRM Controller Features The Addfield PLC Controller has been developed to provide you with a simple yet effective operational process. Designed around a touch screen HMI interface, and independent burner control buttons and switches. The touch screen interface provides all of your essential operations at the press of a finger. Having pre-loaded programmes optimised for your individual requirements, waste...

 Open the catalog to page 3
Addfield GM500 Medical Waste Incinerator Datasheet-4

CHECKED APPROVED CHECKED APPROVED FRONT VIEW OPEN LID CHECKED APPROVED CHECKED APPROVED COMMENTS CHECKED APPROVED COMMENTS SIDE VIEW ISOMETRIC VIEW This drawing and any information or descriptive material set out on it are the confidential and copyright propertyof Addfield Enviromental Systems, and MUST NOT BEDISCLOSED, COPIED, LOANED in whole or part or used for any purpose without the written permission of Addfield Enviromental Systems. Addfield Environmental Systems LTD (2018) DATE CREATED: Addfield Environmental Systems LTD Unit 9, Zone 4 Burntwood Business Park Staffordshire WS7 3XD (UNLESS...