Addfield GM250 Medical Waste Incinerator Datasheet
4Pages

{{requestButtons}}

Catalog excerpts

Addfield GM250 Medical Waste Incinerator Datasheet - 1

The Addfield General Medical (GM) range of Incinerators. Compact top loading incinerator for secure disposal of sharps, general medical, clinical, and pathological waste. Primary Chamber QUALITY ASSURED FIRM QUALITY ASSURED FIRM The GM250 is a compact medical waste incinerator. Designed for complete destruction of general medical waste. Manufactured to deliver optimum results through retaining maximum heat within the main chamber. Constructed with a multi layered 180mm brick refractory placing our machines at the forefront of quality. The GM250 has a 0.45m³ chamber volume, making it ideal for smaller hospitals and clinical practices. Utilising pulse firing burners, our GM range of incinerators are up to 40% more efficient than other machines, saving fuel and money. Machine Specification External L x W x H (mm) Weight (approx tonnes) Nominal Burn Rate UK* (kg/hr) Burn Rate [Export Only]* (kg/hr) • Pre-cast block impact zone protecting refractory lining during loading. • Heavily insulated internal brick refractory, constructed along an interlocking systems to ensure maximum strength and resilience. • Premium grade high alumina content refractory brick work delivering optimal thermal retention. • Top loading counter balanced insulated access lid. • Temperature controlled waste ignition burner automatic on-off, complete with internal air fans. Secondary Chamber • Fully insulated internal refractory lining. Constructed from high grade low thermal mass insulation. • Temperature controlled Secondary chamber burnout burner with automatic on-off control, complete with internal air fans. • Integrated combustion burner air fans automatically controlling distribution to designated areas. • Temperature sensor mounting point at the top of the chamber, ensuring the chamber reaches the required 1100°C minimum, with a 2 second retention time. Thermal Capacity (kW) Power Supply 50/60 hz Door Aperture Control Panel Waste Type Clinical Waste Treated Waste Fuel Types Anatomical Waste Insulation Board Cytotoxic & Cytostatic Waste Insulation Fire Brick Fire Brick (Alumina) Offensive/Hygiene Waste *We reserve the right to change the specification, dimensions and quality of materials from time to time, so long as the alteration is minor or an improvement to the said product. Medicinal Waste Domestic (municipal) Waste Addfield Environmental Systems Limited Unit 9 | Zone 4 | Burntwood Business Park Staffordshire | WS7 3XD | United Kingdom © Addfield Environmental Systems Ltd. All information should be used as a guide only, specifications are

Open the catalog to page 1
Addfield GM250 Medical Waste Incinerator Datasheet - 2

The Addfield General Medical (GM) range of Incinerators. Waste Loading and De-Ashing The GM range of incinerators are designed for top loading directly into the primary chamber. Loading can be manual or mechanically through digger or hydraulic bin tippler. To be loaded no more than once per day prior to operation. The incineration process will reduce the waste to approximately 3% volume, ash. The ash should be removed before the following waste is loaded to ensure optimum burn rates. Optional de-ashing doors are available. The Addfield Difference • Pre-Fabricated 8mm & 10mm robust mild...

Open the catalog to page 2
Addfield GM250 Medical Waste Incinerator Datasheet - 3

www.addfield.com Control Panel Addfield Intelligent PLC Controller Simple to operate adaptive control system for achieving optimal results from your machine. QUALITY ASSURED FIRM QUALITY ASSURED FIRM Controller Features The Addfield PLC Controller has been developed to provide you with a simple yet effective operational process. Designed around a touch screen HMI interface, and independent burner control buttons and switches. The touch screen interface provides all of your essential operations at the press of a finger. Having pre-loaded programmes optimised for your individual requirements,...

Open the catalog to page 3
Addfield GM250 Medical Waste Incinerator Datasheet - 4

CHECKED APPROVED PLAN VIEW CHECKED APPROVED FRONT VIEW OPEN LID CHECKED APPROVED CHECKED APPROVED COMMENTS CHECKED APPROVED COMMENTS SIDE VIEW ISOMETRIC VIEW This drawing and any information or descriptive material set out on it are the confidential and copyright propertyof Addfield Enviromental Systems, and MUST NOT BEDISCLOSED, COPIED, LOANED in whole or part or used for any purpose without the written permission of Addfield Enviromental Systems. Addfield Environmental Systems LTD (2018) DATE CREATED: Addfield Environmental Systems LTD Unit 9, Zone 4 Burntwood Business Park Staffordshire...

Open the catalog to page 4

All Addfield Environmental Systems catalogs and technical brochures

  1. A50-IC (1)

    3 Pages

  2. MINI AB

    3 Pages

  3. A50L

    3 Pages

  4. TB

    3 Pages

  5. N20-AA

    5 Pages

  6. N20

    5 Pages

  7. PHOENIX 3

    5 Pages

  8. PHOENIX 2

    5 Pages

  9. PHOENIX 1

    5 Pages

  10. N20-SA

    5 Pages