BMK SERIES TECHNICAL DATA SHEET Benchmark 6000 Condensing Hydronic Boilers The AERCO Benchmark 6000 Water Boiler is designed for condensing application in any closed loop hydronic system. It delivers 15:1 burner turndown to match energy input directly to fluctuating system loads to yield the highest possible seasonal efficiencies. And no other product packs as much capacity into such a small footprint. To minimize emissions, the BMK6000 is fitted with a low NOx burner whose emissions will consistently measure <20 ppm of NOx corrected to 3% excess oxygen at all firing rates. The fully modulating burner also maintains AERCO standards for energy efficiency, longevity, reliability and construction quality. The BMK6000 comes standard with AERCO’s Patent Pending, Oxygen Level (O2) monitoring system. This monitoring system, designed to display the O2 level directly on the unit in real time, can also be remotely monitored via Modbus giving the customer the ability to measure the emissions level and fuel economy of the boiler without traditional combustion calibration devices. The BMK6000 can be used as an individual unit or in modular arrangements and offers selectable modes of operation. In addition to controlling the boiler according to a constant set point, indoor/outdoor reset schedule or 4-20mA signal, one or more units can be integrated via Modbus communications protocol to AERCO’s multiple boiler management system (BMS) or a facilitywide Energy Management or Building Automation System. Natural Gas or Dual Fuel (Propane) 15:1 Turndown Ratio (7%) Oxygen Level (O2) Monitoring Standard Stainless Steel Fire Tube heat exchanger Capable of variable primary flow Installations NOx Emissions 20 ppm or less @ all firing rates Compact Footprint (79”H x 34”W x 108”D) Precise Temperature Control Ducted Combustion Air Capable Easy Open Access for Service Acceptable vent materials AL29-4C Reliable Quiet Operation Controls Options • Constant Setpoint • Indoor/ Outdoor Reset • Remote Setpoint •
Open the catalog to page 1
RATINGS AND DIMENSIONS: Model AHRI Certified Weight Weight Shipping (dry) (wet) lbs. Weight lbs. 3,000 SPECIFICATIONS: ASME Working Pressure………………… 80 PSIG or 150 PSIG Electrical Options……………………………… 208/3/60 30 AMP ……………………………………………………460/3/60 15 AMP Gas Requirements: Natural Gas FM Gas Train ……………………… 14” W.C. Min. @ Full Load DBB (IRI) Gas Train………………… 14” W.C. Min. @ Full Load Dual Fuel FM Gas Train - Nat Gas……………… 14” W.C. Min. @ Full Fire FM Gas Train - Propane……………… 14” W.C. Min. @ Full Fire Water Connections …………………6” Flanged 150lb ANSI Vent/ Air Intake Connections…………………… 14 Inch...
Open the catalog to page 2All AERCO International catalogs and technical brochures
-
ReCon Water Heater
3 Pages
-
SmartPlate Water Heaters
6 Pages
-
Benchmark Series
12 Pages
-
AERCO Corporate Brochure
12 Pages
-
U-Tube Double Wall
2 Pages
-
Water-Wizard B+II
12 Pages
-
Innovation Family
10 Pages
-
AM Series
12 Pages
-
AM-Series-Boiler
4 Pages
-
C - MORE
4 Pages
-
AER-1057-BMK-Fam
14 Pages
-
BMK-SERIES
4 Pages
-
Innovation 800
2 Pages
-
Innovation 600
2 Pages
-
Modulex Family Brochure
8 Pages
-
Modulex EXT
4 Pages
-
Esteem 399
2 Pages