Group: B. Braun Melsungen
Catalog excerpts
General open surgery Csc-kol® Intraluminal Stapler for Single Use Innovation in Low Colorectal Anastomosis with Transanal Control
Open the catalog to page 1CSC-KOL® INTRALuMINAL STAPLER FOR SINGLE uSE EXISTING CLINICAL PROBLEMS INNOvATION IN LOw COLORECTAL ANASTOMOSIS wITh TRANSANAL CONTROL · Total mesorectal excision (TME) is the gold standard technique for rectal surgery as it decreases local recurrence and improves functional results1. · On the other hand, the introduction of the double stapling technique (DST) has greatly facilitated the anastomosis after low anterior resection (LAR); it obviates the use of lower purse-string suture and permits a lower and easier anastomosis 2. · however, stapling across staple lines and the lateral Fig....
Open the catalog to page 2Surgical Steps KOL® – Technique for a real Transanal End-to-End Anastomosis 1. Transanally suture the distal staple line Firstly stitch the left end of the staple line. Suture another three or four points until the right end of the staple line. (Fig. 2) ··Pull the two groups of sutures into the right and left traction holes separately, by using the suture threader. (Fig. 3) Fig. 2 2. Anastomosis Close the stapler into the green zone, while pulling the staple line into the housing and fire the stapler. ··Check the specimen to make sure the complete resection of the distal staple line. The...
Open the catalog to page 3Power-Cut Improved technology to cut through intersecting staples. Just-Fit & Uni-Link enhance direct firing force transition and use parallel tissue compression and staple formation. Csc-kol® Innovation Four Traction Holes allow to pull the staple line and the tissue into the housing. product features and benefits Double specimen housing 12.6 - 17.8 cm3 to accomodate the staple line and the desired amount of tissue to be resected. Stapler intraluminal
Open the catalog to page 4REFERENCES 1 Kawada K, hasegawa S, Koya h, hirai K, Okoshi K, Nomura A, et al. Risk factors for anastomotic leakage after laparoscopic low anterior resection with DST anastomosis. Surg Endosc. 2014;28:2988-95. 2 Cohen Z, Myers E, Langer B, Taylor R, Railton Rh, Jamieson C. Double stapling technique for low anterior resction. Dis Colon Rectum. 1983;26(4):231-5. 3 Kuroyanagi h, Oya M, ueno M, Fujimoto y, yamaguchi T, Muto T. Standardized techniqueof laparoscopic intracorporeal rectal transection and anastomosis for low anterior resection. Surg. Endosc. 2008;22:557-61. 4 Rudi M, Roumen h,...
Open the catalog to page 5Manufacturer acc. to MDD 93/42/EEC Touchstone International Medical Science Co., Ltd. | 21 A Science Plaza International Science Park | No. 1355 Jinjihu Avenue | Suzhou | China Distributed by: B. Braun Surgical, S.A. | Carretera de Terrassa, 121 | 08191 Rubí | Spain Phone +34 93 586 6200 | Fax +34 93 699 6330 | www.bbraun.com Aesculap ® – a B. Braun brand Aesculap AG | Am Aesculap-Platz | 78532 Tuttlingen | Germany Phone +49 7461 95-0 | Fax +49 7461 95-2600 | www.aesculap.com The product trademark “KOL” is a registered trademark of Touchstone International Medical Science Co., Ltd. Subject...
Open the catalog to page 6All Aesculap® catalogs and technical brochures
-
proGAV ® 2.0
36 Pages
-
Targon® FN
36 Pages
-
AESCULAP® NEUROENDOSCOPY
128 Pages
-
AESCULAP® Metha®
28 Pages
-
AESCULAP® BULLDOG CLIPS
8 Pages
-
Quintex®
8 Pages
-
MONOMAX®
16 Pages
-
Premilene® Mesh Plug
8 Pages
-
AESCULAP® Excia® 12/14
18 Pages
-
Aesculap®
16 Pages
-
VascuFlex®
12 Pages
-
Aesculap Aeos®
16 Pages
-
LC – LINEAR CUTTER STAPLER
6 Pages
-
M.blue®
44 Pages
-
Nelson® deluxe
8 Pages
-
CARDIOLOGY
44 Pages
-
Aesculap® Targon® RF
28 Pages
-
Aesculap® OrthoPilot®
52 Pages
-
TrendHip®
16 Pages
-
proSA®
30 Pages
-
activ L®
44 Pages
-
AESCULAP® SINGLE USE PRODUCTS
88 Pages
-
AESCULAP® CoreHip® SYSTEM
36 Pages
-
AdTec® bipolar
8 Pages
-
Aesculap Surgical Instruments
64 Pages
-
EV3.0 CAMERA CONTROL UNIT
12 Pages