Product catalog summary
Product Overview:
Diacap® Acute S, M, and L are hemofilters designed for intensive care blood purification. They are made from polysulfone membrane material with an internal diameter of 200 μm and a wall thickness of 40 μm. The surface area varies among the models: 1.0 m² for Acute S, 1.5 m² for Acute M, and 2.0 m² for Acute L.
Specifications:
  • Priming volume (blood-side): 58 ml for Acute S, 90 ml for Acute M, and 121 ml for Acute L.
  • Maximum Transmembrane Pressure (TMP): 600 mmHg for all models.
  • Maximum blood flow: 300 ml/min for Acute S and 500 ml/min for Acute M and L.
  • Mode of sterilization: Gamma for all models.
  • Units per box: 20 for each model.
Performance Data:
The sieving coefficients for various molecules are provided, indicating the filter's efficiency in removing substances of different molecular weights. For example, Vitamin B12 has a sieving coefficient of 1, while Albumin has a coefficient of 0.005.
In-vitro Performance:
Performance is measured according to EN 1283 standards using human blood with specific hematocrit and protein levels. The filters are suitable for various procedures such as SCUF, CVVH, HV CVVH, CVVHD, CVVHDF, and CVVHFD.
Ultrafiltration Rates:
Graphs indicate the ultrafiltration rates for each model at different transmembrane pressures and blood flow rates (QB). The rates are measured using bovine blood with specified hematocrit and protein levels.
Contact Information:
B. Braun Avitum AG, Germany. Contact details include phone, fax, and email for further inquiries.
See more

Catalog excerpts

Diacap® Acute-1

SHARING EXPERTISE Diacap® Acute Product InformationIntensive Care Blood Purification (ICBP) Hemofilter ■ SCUF slow continuous ultrafiltration ■ CVVH continuous veno-venous hemofiltration ■ HV CVVH high volume CVVH ■ CVVHD continuous veno-venous hemodialysis ■ CVVHDF continuous veno-venous hemodiafiltration ■ CVVHFD continuous veno-venous high flux dialysis Diacap® Acute S Diacap® Acute M Diacap® Acute L Membrane material Polysulfone Polysulfone Polysulfone Priming volume blood-side ml 58 90 121 Max. blood flow ml/min 300 500 500 Mode of sterilization Gamma Gamma Gamma Sieving Coefficient In-vitro performance and physical data according to EN 1283; (In-vitro Sieving Coefficient: human blood, Hct. 32%, protein 60 g/l, Qf 20% from Qb)

 Open the catalog to page 1
Diacap® Acute-2

SHARING EXPERTISE In-vitro ultrafiltration rate: bovine blood, Hct. 32%, protein 60 g/l Transmembrane pressure (mmHg) Diacap® Acute M Ultrafiltration Rate 3 150 In-vitro ultrafiltration rate: bovine blood, Hct. 32%, protein 60 g/l 400 Transmembrane pressure (mmHg) Diacap® Acute L Ultrafiltration Rate Qb = 300 ml/min Qb = 200 ml/min Qb = 100 ml/min Transmembrane pressure (mmHg) In-vitro ultrafiltration rate: bovine blood, Hct. 32%, protein 60 g/l B. Braun Avitum AG | Schwarzenberger Weg 73-79 | 34212 Melsungen | GermanyTel. +49 5661 71-2624 | Fax +49 5661 75-2624 | [email protected] | www.bbraun-dialysis.com...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About MedicalExpo
MedicalExpo is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. MedicalExpo is an entity of VirtualExpo Group.