1. Catalogs
  2. Aesculap®
  3. PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY

PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY

PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY
1 / 36 PagesView full catalog

PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY

Product catalog summary
Catalog Overview
The B. Braun Vascular Systems catalog provides a comprehensive overview of peripheral interventional vascular diagnostics and therapy products. It includes specifications and features of devices such as drug-coated balloon catheters, stent systems, vena cava filters, and vascular prostheses.
Peripheral Angioplasty
The SeQuent® Please OTW series of drug-coated balloon catheters are highlighted for treating peripheral artery disease (PAD). These catheters use a coating technology to inhibit neointimal proliferation and deliver paclitaxel effectively, with models for both below and above the knee applications.
Stent Systems
The VascuFlex® series includes multiple and single stent systems designed to reduce metal in vessels and preserve biomechanics. The VascuFlex® Multi-LOC system allows multiple stents to be implanted with one delivery system, while the VascuFlex® 5F and 6F systems offer flexible architecture and excellent visibility.
Vena Cava Filters
The VenaTech® series offers permanent, retrievable, and convertible filters for enhanced clot trapping, suitable for patients with contraindications to anticoagulants.
Vascular Implants
Details on vascular prostheses include the Silver Graft and Uni-Graft® series. Silver Graft prostheses are antimicrobial with a silver coating, while Uni-Graft® K DV prostheses are warp-knitted and impregnated with bovine gelatine for zero porosity.
Angiography Accessories
Includes radiology kits and accessories like guidewires, angiographic syringes, and inflation devices to support angiographic procedures.
Product Specifications and Features
Features include ergonomic designs for better handling, inflation devices with unique adaptors, and angiographic syringes with advanced mechanisms.
Manufacturer Information
B. Braun Melsungen AG, Vascular Systems, Berlin, Germany. Contact details and website provided.
Trademarks and Legal Notice
Trademarks include 'SeQuent', 'VascuFlex', 'VenaTech', and others. Legal notice states the brochure is for informational purposes only.
See more

Catalog excerpts

PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY-1

INTERVENTIONAL VASCULAR THERAPY PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY

 Open the catalog to page 1
PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY-2

B. BRAUN VASCULAR SYSTEMS PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS AND THERAPY VascuFlex® Peripheral stent systems VenaTech® Vena Cava Filter Silver Graft Vascular Patch Angiodyn® Radiology Kits

 Open the catalog to page 2
PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY-3

PERIPHERAL ANGIOPLASTY Peripheral drug coated balloon catheter 4 – 5 SeQuent ® Please OTW 014 (below the knee) SeQuent ® Please OTW 018 (below and above the knee) SeQuent ® Please OTW 035 (above the knee) Peripheral self-expanding Nitinol stent 8 VascuFlex® Multi-LOC Multiple stent system (MSS) 9 VascuFlex® 2-LOC, 3-LOC Multiple stent system (MSS) 10 – 11 VascuFlex® 5F, 6F Single stent system VascuFlex® 5F TR/TB Single stent system VENA CAVA FILTER Uni-Graft® W Aortic Arch Woven, impregnated vascular prostheses VascuGraft® NEO Standard vascular ePTFE prostheses VascuGraft® FLOW Heparin coated...

 Open the catalog to page 3
PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY-4

SeQuent® Please OTW PERIPHERAL DRUG COATED BALLOON CATHETER The interventional approach to treat peripheral artery disease (PAD) as a treatment of choice is gaining continuous acceptance. Following a path of sustained research and development in drug coated balloons SeQuent® Please OTW offers significant improvements in peripheral angioplasty. SeQuent ® Please OTW - From the pioneer in coating technology Clinically proven coating technology1 Effectively inhibiting neointimal proliferation Novel paclitaxel B. Braun Matrix coating with Resveratrol Excellent handling The CONSEQUENT randomised trial...

 Open the catalog to page 4
PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY-5

SeQuent® Please OTW 014 PERIPHERAL DRUG COATED BALLOON CATHETER Rated burst pressure (atm)

 Open the catalog to page 5
PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY-6

SeQuent® Please OTW 018 PERIPHERAL DRUG COATED BALLOON CATHETER Rated burst pressure (atm)

 Open the catalog to page 6
PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY-7

SeQuent® Please OTW 035 PERIPHERAL DRUG COATED BALLOON CATHETER Rated burst pressure (atm)

 Open the catalog to page 7
PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY-8

VascuFlex® Multi-LOC MULTIPLE STENT SYSTEM (MSS) VascuFlex® LOC portfolio enables the implantation of several stents with one delivery system. The aim of the spot and focal stenting strategies with the VascuFlex ® Multiple Stent Systems is to reduce the amount of metal in the vessel and thus preserve the natural biomechanics of the vessel in the best possible way. With the VascuFlex ® LOC portfolio, all stents can be implanted individually in challenging indications (e.g. recoils, flow-limiting dissections). The LOCOMOTIVE Register has demonstrated the safety and efficacy of VascuFlex ® Multi-LOC...

 Open the catalog to page 8
PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY-9

VascuFlex® 2-LOC/3-LOC MULTIPLE STENT SYSTEM (MSS) Order number Delivery System Order number

 Open the catalog to page 9
PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY-10

VascuFlex® 5 F and 6 F SINGLE STENT SYSTEM Wide portfolio 5 F & 6 F delivery systems 5 - 10 mm stent diameter 20 - 200 mm stent length 80 cm, 120/130 cm shaft length Flexible stent architecture Open cell design Good vessel apposition Double-polished Minimal foreshortening Excellent stent visibility with laser-welded tantalum markers Proven delivery system High flexibility Radiopaque platinum markers Superb kink resistance Excellent pushability Different shaft lengths: 80 cm, 120/130 cm 5 F System with 0.018” guide wire compatibility 6 F System with 0.035” guide wire compatibility

 Open the catalog to page 10
PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY-11

VascuFlex® 5 F and 6 F SINGLE STENT SYSTEM

 Open the catalog to page 11
PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY-12

VascuFlex® 5 F Transradial/Transbrachial SINGLE STENT SYSTEM Nitinol stent system for radial and brachial approach 5 F low profile device 0.018” guidewire compatibility Extra long 180 cm shaft length 6 – 8 mm stent diameter for SFA lesions 40 – 80 mm stent length Flexible stent architecture Open cell design Good vessel apposition Double-polished Minimal foreshortening Excellent stent visibility with laser-welded tantalum markers Stent length (mm) VascuFlex® 5 F TR/TB, 180 cm Shaft length 40 60 80 Radiodyn guidewire SFC-400/4-018 Very long guidewire for transradial/transbrachial procedures 400...

 Open the catalog to page 12
PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY-13

Vena Cava Filter FOR PROTECTION AGAINST PULMONARY EMBOLISM VenaTech® Vena cava filter systems - Designed for enhanced clot trapping - Special delivery system combining ease of use and procedural safety Indications: - Contraindications to anticoagulants (severe coagulopathy, thrombocy openia, t hemorrhage, recent brain surgery, recent cranial trauma) - Failure of the anticoagulants treatment (recurrent pulmonary em olism b under treatment development of clot in spite of anti-coagula ion) t - Severe complication of the anticoagulants treatment (intestinal hemorrhage, gastroduodenal ulcer) Additional...

 Open the catalog to page 13
PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY-14

Silver Graft ANTIMICROBIAL VASCULAR PROSTHESES Silver Graft and Silver Graft Helix are warp-knitted, double-velour vascular prostheses for reconstructive procedures of the aorta and in the peripheral area. They are made of polyester and have been impregnated with absorbable modified bovine gelatine for temporary sealing. To inhibit microbial adhesion the outer surface of the prosthesis is coated by a layer of metallic silver. According to the current guidelines for vascular graft infections of the German Society for Vascular Surgery (DGG) it is possible to apply antibiotics (e. g. Rifampicin)...

 Open the catalog to page 14
PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY-15

Silver Graft ANTIMICROBIAL VASCULAR PROSTHESES Order number Order number Order number Silver Graft – Straight tubes - Helix supported 30 40 60 90 Silver Graft – Bifurcations Silver Graft – Axillo-Bifemoral - Helix supported 90 / 60

 Open the catalog to page 15
PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY-16

Uni-Graft® K DV WARP-KNITTED, IMPREGNATED VASCULAR PROSTHESES Uni-Graft® K DV Uni-Graft® K DV is a warp-knitted, double velour vascular prosthesis made of polyester, which has been impregnated with absorbable modified bovine gelatine. This treatment reduces the initial porosity of the textile prosthesis to a „zero porosity“ at the time of implantation. Indications Reconstructive procedure on the aorta and in the peripheral area with a diameter of at least 6 mm and the axillo (bi)femoral bypass; also usable in patients requiring systemic heparinization, in patients with coagulation disturbances...

 Open the catalog to page 16
PERIPHERAL INTERVENTIONAL VASCULAR DIAGNOSTICS & THERAPY-17

Uni-Graft® K DV WARP-KNITTED, IMPREGNATED VASCULAR PROSTHESES Order number Uni-Graft® K DV – Straight tubes 15

 Open the catalog to page 17
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.