Orthopaedic Joint Replacement TrendHip® Self-Locking Cementless or Cemented Hip Stem

Open the catalog to page 1
TrendHip® - 2

design concept surgical technique

Open the catalog to page 2
TrendHip® - 3

Proven Design. HA-Coated. Straight forward. 3

Open the catalog to page 3
TrendHip® - 4

TrendHip® 2 | design concept Self-Locking Cementless or Cemented Hip stem. The TrendHip® design concept combines the traditional features of a straight tapered and fully surface coated cementless hip stem. The TrendHip® triple tapered shape additionally supports the implant positioning inside the femoral cavity. The cementless rectangular self-locking stem enables a reliable primary stable implant position and a direct secondary periprosthetic bone contact to the coated surface. The hydroxylapatite surface is a combined double layer of a rough titanium plasmaspray coating in the proximal...

Open the catalog to page 4
TrendHip® - 5

Stem length Stem length Stem length Offset standard Offset lateralized

Open the catalog to page 5
TrendHip® - 6

TrendHip® 3 | SURGICAL TECHnIqUE 1 | Planning Planning templates are available at 115 % scale. Digital templates are available on request. 2 | Femur Osteotomy After the femoral neck resection the medullary canal is opened with the box osteotome.

Open the catalog to page 6
TrendHip® - 7

3 | Femur Preparation The medullary canal is prepared with increasing rasp sizes until sufficient stability is achieved. The final implant size selection corresponds to the final rasp size. 4 | Trial Reduction The rasp trial reduction is performed with a trial neck and modular trial heads. To simulate standard as well as lateral offset, a trial neck adapter for each case is available. STRAIGHT FORwARD SURGICAL TECHnIqUE.

Open the catalog to page 7
TrendHip® - 8

TrendHip® 3 | SURGICAL TECHnIqUE 5 | Cement Plug Preparation and Bone Cement Application The medullary canal is prepared in exactly the same way as for the TrendHip® cementless version. To implant the cemented option the following additional step is required. The application of a cement plug is mandatory before the application of the bone cement. If an artificial cement plug is used, the application of the cement plug depends on its instruction for use. The distal femoral canal size is measured 10 mm below the distal implant tip level with intramedullary probes. After the cement plug has...

Open the catalog to page 8
TrendHip® - 9

7 | Joint Reduction The joint stability can be finally checked with the trial heads. The appropriate prosthesis head is then connected on the cleaned and dried taper.

Open the catalog to page 9
TrendHip® - 10

TrendHip® Cementless Stems Standard Offset Standard Offset Lateralized Offset Lateralized Offset TrendHip® Cemented Stems Size IMSET CEMENT PLUG 10 mm Composition Gelatine (from pigs) Glycerine Water Methylparahydroxybenzoate 10

Open the catalog to page 10
TrendHip® - 11

Biolox® delta Implant Materials - Biolox® delta Aluminium oxide matrix ceramic (ISO 6474-2) - Hydroxylapatite (ISO 13799-1)* - ISODUR®F Cobalt-chromium forged alloy (ISO 5832-12) - Stainless steel (ISO 5832-9)* - Titanium alloy (Ti6Al4V / ISO 5832-3)* * TrendHip® stems are manufactured by Groupe Lépine, 175 Rue Jacquar

Open the catalog to page 11
TrendHip® - 12

Please order separately TrendHip® tray Handle for lateral approach Graphic template Handle for posterior approach Handle for anterior approach Stem impactor Handle lat. approach offset left Handle lat. approach offset right Handle ant. approach offset left Handle ant. approach offset right Handle for lateral approach Handle lat. approach offset left Handle lat. approach offset right Impaction instrument Extraction adapter Locked impactor

Open the catalog to page 12
TrendHip® - 13

Please order separately TrendHip® rasp size 1 TrendHip® X-ray templates, standard offset, Scale 1.15:1 TrendHip® rasp size 2 TrendHip® X-ray templates, lateralized offset, Scale 1.15:1 TrendHip® rasp size 3 TrendHip® rasp size 4 TrendHip® rasp size 5 TrendHip® rasp size 6 TrendHip® rasp size 7 TrendHip® rasp size 8 TrendHip® trial neck standard TrendHip® trial neck later

Open the catalog to page 13
TrendHip® - 16

Manufacturer according to MDD 93 / 42 / EEC Groupe Lépine | 175 Rue Jacquard | 69730 Genay | France Aesculap ® – a B. Braun brand Aesculap AG | Am Aesculap-Platz | 78532 Tuttlingen | Germany Phone +49 7461 95-0 | Fax +49 7461 95-2600 | www.aesculap.com The main product trademark “Aesculap” and the product trademark “ISODUR” are registered trademarks of Aesculap AG. “TrendHip” is a registered trademark of B. Braun Melsungen AG. “Biolox” is a registered trademark of CeramTec GmbH, Plochingen. Subject to technical changes. All rights reserved. This brochure may only be used for the exclusive...

Open the catalog to page 16

All Aesculap® catalogs and technical brochures

  1. proGAV ® 2.0

    36 Pages

  2. Targon® FN

    36 Pages

  3. Quintex®

    8 Pages

  4. MONOMAX®

    16 Pages

  5. Aesculap®

    16 Pages

  6. VascuFlex®

    12 Pages

  7. M.blue®

    44 Pages

  8. CARDIOLOGY

    44 Pages

  9. proSA®

    30 Pages

  10. activ L®

    44 Pages