Group: B. Braun Melsungen
Catalog excerpts
VascuFlex® Self-Expanding Peripheral Nitinol Stents INTERVENTIONAL VASCULAR THERAPY
Open the catalog to page 1VascuFlex® Multi-LOC Spot stenting system CONSEQUENTLY LESS METAL Biomechanical challenges in femoropopliteal arteries Flexion Extension / contraction Possible complications of long stents and consequences Double polished surface Stent fractures Disturbance of natural vessel movement Chronic vessel wall trauma Restenosis / Late Lumen Loss Reocclusions / reinterventions Six freely positionable stents on one delivery system Short stents with high radial force (closed cell design) (1) Data on file at B. Braun. (2) Amendt K, et al. Vasa (2017), 1–10.doi.org/10.1024/0301-1526/a000658. (3) Sigl M,...
Open the catalog to page 2LOCOMOTIVE EXTENDED STUDY: 12-MONTH DATA (2, 3, 4) 357 patients 71.1 % Rutherford stages 3 to 5 Lesions in SFA and popliteal artery (segments 1 to 3) with vessel diameter: 5.5 ± 1.1 mm Average lesion lengths: 16.0 ± 9.7 cm Calcification: 85.7 % Less acute and chronic trauma due to less material in vessel wall (2, 3, 4) Chronic total occlusion: 31.4 % TASC C&D lesions: 44.5 % TLR rate at 6 months (primary endpoint): 4.5 % (Revaskularisation rate of the target lesion) Secondary endpoints: TLR at 12 months, patency (Duplex ultrasound), Rutherford classification, amputation rate, ABI and walking...
Open the catalog to page 3VascuFlex® 2-LOC and 3-LOC Focal stenting systems UNDRESS THE FULL METAL JACKET Maintain the natural vessel motion System with two or three 30 or 40 mm short, freely positionable stents Cover lesions only where it is needed Short stents are less likely to fracture Stent diameters 5 - 8 mm for femoropopliteal lesions Less metal and moderate radial force for reduced trauma to the vessel wall Implantation of up to three stents with one delivery system Flexible stent architecture Open cell design for good vessel apposition Double polished surface Excellent stent visibility with laser-welded...
Open the catalog to page 4Implantation of up to 3 stents with one system Good wall apposition Each stent freely positionable Flexible open cell stent design
Open the catalog to page 5VascuFlex® 5 F and 6 F Peripheral self-expanding nitinol stent DIVERSITY IN DAILY ROUTINE 5 F and 6 F delivery systems 5 - 10 mm stent diameter Good wall apposition 20 - 200 mm stent lengths 80 and 120 / 130 cm shaft lengths Proven pin and pull delivery system Facilitates controlled and precise stent implantation ePTFE-liner for smooth-running and uniform stent release High flexibility Radiopaque platin markers (on the inner catheter) Circular nitinol marker on outer catheter Good kink resistance Excellent pushability (1) (1) Data on file at B. Braun. 6 Flexible open cell stent design
Open the catalog to page 6Radiopaque markers for improved visibility Double polished surface Minimal foreshortening TRANSRADIAL-/ BRACHIAL 5 F system with 180 cm shaft length (0.018“ guide wire lumen) For transradial and transbrachial access Low, 5 F profile Brachial artery Radial artery
Open the catalog to page 7ORDER INFORMATION VascuFlex® LOC VascuFlex ® Multi-LOC 130 cm shaft length VascuFlex Multi-LOC 80 cm shaft length ® VascuFlex® 2-LOC VascuFlex 2-LOC 80 cm shaft length VascuFlex ® 2-LOC 130 cm shaft length VascuFlex 2-LOC 80 cm shaft length VascuFlex ® 2-LOC 130 cm shaft length VascuFlex® 3-LOC VascuFlex 3-LOC 80 cm shaft length VascuFlex ® 3-LOC 130 cm shaft length VascuFlex ® 3-LOC 80 cm shaft length VascuFlex ® 3-LOC 130 cm shaft length *available upon
Open the catalog to page 8ORDER INFORMATION VascuFlex® 5 F VascuFlex ® 5 F TR/TB 180 cm shaft length VascuFlex ® 5 F 120 cm shaft length VascuFlex ® 5 F 80 cm shaft length 5505129 *available upon request Radiodyn PTFE coated nitinol guide wire, Sales unit: 5 pieces Order Number
Open the catalog to page 9ORDER INFORMATION VascuFlex® 6 F VascuFlex ® 6 F 130 cm shaft length VascuFlex ® 6 F 80 cm shaft length *available upon request Technical information Recommended introducer sheath Recommended guide wire VascuFlex® Multi-LOC VascuFlex TR/TB
Open the catalog to page 10CONSEQUENTLY LESS METAL in the treatment of complex lesions
Open the catalog to page 11B. Braun Melsungen AG | Vascular Systems | Sieversufer 8 | 12359 Berlin | Germany Phone +49 30 568207-300 | Fax +49 30 568207-210 | www.bbraun.com Manufacturer acc. to MDD 93/42/EEC: B. Braun Melsungen AG, Carl-Braun-Str. 1, 34212 Melsungen, Germany The product trademarks ‘Angiodyn’, ‘SeQuent’ and ‘VascuFlex’ are registered trademarks of B. Braun Melsungen AG. Subject to technical changes. All rights reserved. This brochure may only be used for the exclusive purpose of obtaining information about our products. Reproduction in any form partial or otherwise is not permitted.
Open the catalog to page 12All Aesculap® catalogs and technical brochures
-
proGAV ® 2.0
36 Pages
-
Targon® FN
36 Pages
-
AESCULAP® NEUROENDOSCOPY
128 Pages
-
AESCULAP® Metha®
28 Pages
-
AESCULAP® BULLDOG CLIPS
8 Pages
-
Quintex®
8 Pages
-
MONOMAX®
16 Pages
-
Premilene® Mesh Plug
8 Pages
-
AESCULAP® Excia® 12/14
18 Pages
-
Aesculap®
16 Pages
-
Aesculap Aeos®
16 Pages
-
LC – LINEAR CUTTER STAPLER
6 Pages
-
M.blue®
44 Pages
-
Nelson® deluxe
8 Pages
-
CARDIOLOGY
44 Pages
-
Aesculap® Targon® RF
28 Pages
-
Aesculap® OrthoPilot®
52 Pages
-
TrendHip®
16 Pages
-
proSA®
30 Pages
-
activ L®
44 Pages
-
AESCULAP® SINGLE USE PRODUCTS
88 Pages
-
AESCULAP® CoreHip® SYSTEM
36 Pages
-
AdTec® bipolar
8 Pages
-
Aesculap Surgical Instruments
64 Pages
-
EV3.0 CAMERA CONTROL UNIT
12 Pages