Catalog excerpts

Intramedullary Nails: Tibia, Femur, Trochanter AFTron You have a right to quality
Open the catalog to page 1
AFTron Head Quarter AF-Medical GmbH Pfaffenhaule 60 DE-78224 Singen Sales Branch AF-Medical GmbH Byk-Gulden-Str.18 P +49 7731 144350 info@af-ortho.com
Open the catalog to page 2
Trochanter Nail System Trochnter Nail System Implants & Instruments Version 2.0 Titanium, anodized
Open the catalog to page 3
AFTron AFTron - AF Trochanter Nailing System The AFTron Trochanter Nail is designed for indications involving the treatment of unstable subtrochanteric, pertrochanteric and intertrochanteric fractures. For shaft fractures in combination with trochanteric fractures the long version of AFTron nails is available. The nail is combining many of the features of a dynamic hip screw system and an intramedullary nail. Three different neck-shaft angles are available for lag screw insertion to accommodate various femoral neck anatomy. AFTron nail provides the surgeon the choice of using the lag screw...
Open the catalog to page 4
AFTron trochanteric nail, cannulated Proximal 0 STEEL TITANIUM STEEL TITANIUM STEEL TITANIUM Diameter Length Code-No Code-No Code-No Code-No Code-No Code-No
Open the catalog to page 5
AFTroN - AF Trochanter Nailing System AFTron Interlocking screw, self-tapping STEEL TITANIUM Code-No Code-No Length STEEL TITANIUM Code-No Code-No Length
Open the catalog to page 6
Lag screw, cannulated, self-tapping Screw 0 10.5 mm STEEL TITANIUM Code-No Code-No Length Anti-rotation screw, self-tapping STEEL TITANIUM Code-No Code-No Note The set screw is only required in cases when the anti-rotation screw is not inserted in the trochanter nail. In such a case that compression screw is used in combination with the lag screw. STEEL TITANIUM Code-No Code-No Length
Open the catalog to page 7
AFTroN - AF Trochanter Nailing System AFTron Instrument set for TroN nails Code-No Description Remarks 90-2050 Guide arm trochanter nail 90-2052 Proximal targeting part 125° 90-2054 Proximal targeting part 130° 90-2056 Proximal targeting part 135° 90-2072 Connection bolt for guide arm 90-0250 90-2074 Connection bolt for impaction rod 90-1240 Nail length gauge, X-ray 90-2242 Nail diameter ruler, X-ray 90-1290 Guide wire device 5-0110 Guide wire, threaded, 0 2,5 mm, 380 mm 90-2110 Wire guide sleeve 0 6.5 / 2.5 mm 90-2112 Wire guide sleeve 0 11.0 / 2.5 mm 90-2170 Drill with stop,0 11.0/390...
Open the catalog to page 8
AFTroN – AF Trochanter Nailing System
Open the catalog to page 9
AFTroN – AF Trochanter Nailing System Target arm trochanter nail 90-2050 Proximal targeting arm Code-No Connection bolt for guide arm 90-0250 90-2072 Connection bolt for impaction rod 90-2074
Open the catalog to page 10
AFTroN – AF Trochanter Nailing System Wrench Code-No Nail length gauge, X-ray 90-1240 Nail diameter ruler, X-ray 90-2242
Open the catalog to page 11
AFTroN - AF Trochanter Nailing System AFTron Guide wire, threaded Code-No 0 mm Length, mm 5-0110 2.5 380 Drill sleeve 0 4.0 mm •'I Code-No 0 mm 90-1082 4.0 Protection sleeve 0 9.5 / 8.0 mmDrill sleeve o 8.5 / 6.5 mm Drill sleeve a 13.0 /11.0 mm Code-No 0 mm 90-1100 9.5 / 8.0 Wire guide sleeve a 11.0 / 2.5 mmDrill bit 0 4.0 x 305 mm Code-No 0 mm 90-2112 11.0 / 2.5 Drill bit Code-No 0 mm Length, mm Remarks 90-2164 6.5 350 for anti-rotat. screw Drill with stop,0 11.0/390 mm,cannulatedmmm Code-No 0 mm 90-2170 11.0 Remarks cannulated Drill bit 0 4.0 x 150 mm Code-No 0 mm Length, mm Remarks...
Open the catalog to page 12
AFTroN – AF Trochanter Nailing System Screw driver hex. Ø 3.5 mm Code-No Wrench for ø 11.0 lag screws, cann. 90-2210 Coupling bolt for lag screws, cann 90-2212 Depth gauge for 5.0 locking screws 90-2230 Depth gauge for K-wire 2.5 mm 90-2232 Depth gauge for distal locking 90-1230
Open the catalog to page 13
Intramedullary Nails Femur & Tibia Femur & Tibia Nail System Implants & Instruments Version 2.0 2.1.1
Open the catalog to page 15
AF intramedullary nailing systems for femoral and tibial facture treatments. Antegrade approchaches in femur and tibia bone and retrograde approach for femur fracture treatments. The three nailing systems combines static and dynamic locking mode options. The femur nail is designed as one implant for two approaches, Antegrade and Retrograde. That nail combines all the capabilities and benefits of seperate antegrade and retrograde nailing systems. Reduced inventory is a further adavantage of one nail for two approaches. Design features antegrade - retrograde Femur Nail • Antegrade and...
Open the catalog to page 17
Femur nail, cannulated TITANIUM Proximal 0 Distal 0 Length Cannulation 0 Design features • reduced inventory: one nail for antegrade or retrograde insertion • one nail for left and right side • common 5.0 mm cortical screws • end caps in various sizes available for prevention of bony or soft tissue ingrowth • easy insertion, cannulated design • static or dynamic locking
Open the catalog to page 18
IMPORTANT Tibia nails of be used with locking diameter 8 mm and 9 mm to 4.0 locking screws for distal Various locking options Design features • static or dynamic locking • one nail for left and right side • common 4.0 / 5.0 mm cortical screws • end caps in various sizes available for prevention of bony or soft tissue ingrowth • easy implant removal • easy insertion, cannulated design • two plane fixation with three screws within 30 mm of the nail end • various locking options
Open the catalog to page 19
Interlocking screw, self-tapping TITANIUM Code-No Length Code-No Length Code-No Length Code-No Length Code-No Length Code-No Length Interlocking screw, self-tapping Code-No Length Code-No Length Code-No Length Code-No Length Code-No Length Code-No Length
Open the catalog to page 20
TITANIUM STEEL Code-No Length Code-No Length
Open the catalog to page 21
Code-No Description Remarks Qty. 90-1050 Guide arm femur / tibia 1 90-1052 Targeting part femur 1 90-1060 Targeting part tibia, medial 1 90-1062 Targeting part tibia, anterior 1 90-1188 Drill / reamer 0 13 mm, cannulated 1 90-1230 Depth gauge for distal locking 1 90-1232 Depth gauge, long 1 90-1240 Nail length gauge, X-ray 1 90-1242 Nail diameter ruler, X-ray 1 90-1290 Guide wire device 1 90-02340 Guide Rod 0 2.4 mm, length 900 mm is supplied separately from tray 1 5-0215 Kirschner wire 0 2.4 mm, length 310 mm, 10
Open the catalog to page 22
Impactor bolt
Open the catalog to page 23