Catalog excerpts

INCLUDING SURGICAL TECHNIQUE GUIDE
Open the catalog to page 1
INNOVATIVE MEDICAL TECHNOLOGY Working with AGOMED means DE Mit AGOMED zu arbeiten, bedeutet mit einem Unternehmen zu arbeiten, dass sich zur working with a company committed Exzellenz und Hochleistung verpflichtet. to excellence. Our products are German engineered, biocompatible, Unsere Produkte werden von deutschen and cutting-edge. Our team Ingenieuren entwickelt, sind biokompatibel, members collectively bring decades innovativ und auf dem neuesten Stand der of medical technology experience to Technik. Unser Team hat jahrzehntelange the table. Erfahrung im Bereich der Medizintechnik....
Open the catalog to page 2
FEATURES & BENEFITS • Low profile plates with a thickness of 3.0 mm - 4.0 mm • Maximum fixation points within each plate • Anatomically designed for use surgical approaches: anterior • Four compression modes available in the system - Anatomic compression hole - Oblong compression hole Oblong Compression Hole For eccentric screw placement and compression. Strong low profile plate Decreases the chance of soft tissue irritation and skin closure • Plate hole accepts 4.0 mm locking and non-locking screws • External Compression Device facilitates controlled compression across the joint Anatomical...
Open the catalog to page 3
ANTERIOR PLATES
Open the catalog to page 4
OPERATION TECHNIQUE Patient Positioning • Arthrodesis of the ankle including tibiotalocalcaneal and tibiotalar joints and tibiocalcaneal arthrodeses, in conjunction with osteotomies and fractures of the distal tibia, talus, and calcaneus. • Position the patient in the supine position, with the heel at end of the table. Place a bump proximal to the ankle. STEP 1 Bone Preparation Decortication of joint surfaces • Ensure that the joint surfaces are prepared congruently. • Provisional fixation of the reduction can be accomplished with a 1.6 mm x 180 mm K-wire (1101058) posterior to where the...
Open the catalog to page 5
STEP 5 Plate Placement Screw Insertion • Frequently there is an irregular surface remaining over the anterior joint which requires debridement to a smooth surface with either a rongeur or saw. Retrieve the appropriate anterior TT plate based on the patient’s anatomy. Tip: Placing the fixed drill guides in the holes prior to temporary plate fixation may facilitate plate positioning and distal screw drilling. • Remove the drill guide and measure screw length using the depth gauge. Confirm screw projection and length using the depth gauge under fluoroscopy. Insert the selected screw size into...
Open the catalog to page 6
• Continue to use either locking or nonlocking screws through the remaining proximal plate holes until the desired fixation is achieved. Wound Closure and Dressing • Use image intensification to confirm adequate plate and screw placement. Then close the wound in layers, and apply a cast in the usual manner. CLINICAL CASE STUDIES • Remove the positioning pin from the tibial screw hole. Use the step outlined in the screw fixation section to drill, measure and fill appropriate 4.0 non-locking screw in the Proximal Slot. Obtain initial compression across the arthrodesis site and secure the...
Open the catalog to page 7
Agopaqx4 AgoFix screw tray 34-55 mm locking, system 4.0, w/o implants Agopaqx4 AgoFix screw tray 34-70 mm standard, system 4.0, w/o implants AgoFix compression/distraction device, 0 - 15 mm AgoFix agopaq system 4.0 instrument tray Agopaqx4 screw tray system 4.0 w/o implants Agopaqx4 tray for implant modules w/4 lids, w/o implant modules Agopaqx4 Ankle Fusion Anterior plate-tray system 4.0, w/o implants
Open the catalog to page 8
Twist drill 3.2 x 145 mm, AO-shaft 50 mm thread, red marker Plate- /screwholding forceps angled, 15cm/6” Agomed depth gauge 60 mm, round f. 2.0 - 4.5 mm screws Silicone ratchet T-handle, AO-shaft right / left / fixed, 13 cm, cannulated, black Silicone ratchet handle, AO-shaft right / left / fixed, 15 cm, non-cannulated, black Twist drill 2.7 x 125 mm, AO 50 mm thread, black marker Screwdriver blade TX 10 noncannulated, interchangeable, AO-shaft AgoFix drill-guide f. drill 3.2 sys. 4.0, screwable, red marking, 65 mm AgoFix drill-guide f. drill 2.7 sys. 4.0, screwable, black marking, 45 mm...
Open the catalog to page 9
Foot & Ankle system Cannulated Screws King Kong Multidirectional Radius system 2.5 Pediatric Screw system 6.2 Titanium plating system for craniomaxillofacial osteosynthesis AgoFix Neuro Plating system 1.5 Titanium Mesh systems for craniomaxillofacial osteosynthesis / Neuro
Open the catalog to page 10
AGOMED Medizin-Technik GmbH Öschweg 29 - D-78567 Fridingen - Germany (+49) 7463 / 267 06 16 info@agomed.com http://www.agomed.com made in germany Ref.num. 2010053 Revision 01 / 06.2020
Open the catalog to page 11All AGOMED Medizin-Technik catalogs and technical brochures
-
Agomed Foot Catalog
101 Pages
-
PANDA FOOT plating system
16 Pages
-
King Kong plating System 2.5
33 Pages
-
Panda Plating System
33 Pages
-
Foot Kelle
1 Pages
-
PANDA Elbow
2 Pages
-
Panda Hand
3 Pages
-
King-Kong Jane Flyer
4 Pages
-
NEURO PLATING SYSTEM 1.5
11 Pages
-
FLATLINE MESH SYSTEM
7 Pages
-
CBS 4.5
2 Pages
-
CBS 7,5
2 Pages
-
CBS 25-39
2 Pages
-
Foot Revision system 2,7 / 3,5
12 Pages
-
Plantar system 2,7
13 Pages
-
Ultra Fit
3 Pages
-
Neuro 2
2 Pages