Catalog excerpts

Compact ALMEMO® measuring instrument 1 measuring input, over 35 measuring ranges Technical data and functions Serie ALMEMO® 2450 10/2016 • We reserve the right to make technical changes. • Generously dimensioned 2-row segment display including units • Easy and convenient to operate by means of 7 keys. • Over 35 measuring ranges for - Thermocouple and NTC sensors For the customer’s own sensors ready-to-use ALMEMO® connectors are available. (see chapter 07) - Atmospheric humidity sensor, capacitive, dewpoint sensor, water detection probe, moisture in wood FHA636MF (see chapter 13) - Pressure transducer FDA602L/D, FD8214, FD8612, Tachometer, turbine flowmeter (see chapter 10) Current clamps FEA604, Voltage / current measuring modules ZA990xAB (see chapter XREF) - Meteorological radiation probe heads FLA613 (see chapter XREF) - Carbon dioxide sensor FYAD00CO2, Carbon monoxide probe and ozone probe (see chapter 15), ALMEMO® plugs with multi-point adjustment are supported. Measuring functions Measured value, zero-setting, saving of maximum / minimum values, hold function Test functions Segment monitoring, range monitoring, sensor breakage indication, battery voltage check and display. Technical data, ALMEMO® 2450 series Measuring input 1 ALMEMO® socket Precision class C (see page 01.04) Measuring rate 2.5 mops Measuring ranges (see 01.05 / 01.06) NiCr-Ni(K), NiCroSil-NiSil(N),Fe-CuNi(L), Cu-CuNi(U), Cu-CuNi(T), PtRh10-Pt(S), Fe-CuNi(J), -200 to +950 °C Double connectors with 2 x differenti al voltage / differential current (input D - B) are not possible. Humidity, capacitive 0 to 100 % RH, (% RH, HcRH, HRH) Dew point, mixture ratio, partial vapor pressure, enthalpy, rotating vanes, digital process (0 / 100 %), frequency, pulse, rotational speed, digital Resolution (see page 01.05 / 01.06) Linearization accuracy (see page 01.05 / 01.06) Standard equipment LCD 7 segments Measured value 5 characters, 15 mm Function 4Z characters, 9 mm 16 segments Units 2 characters, 9 mm 9 symbols Keypad 7 silicone keys Power supply Battery set 3 AA alkaline batteries Current consumption approx. 10 mA without input modules Housing ABS (max. 70 °C) 127 x 83 x 42 mm (LxWxH) Operating temperature -10 to +60 °C Atmospheric humidity (ambient) 10 to 90 % RH (non-condensing) ALMEMO® 2450 series, accessories Order no. Rubberized impact protection, gray ZB2490GS2 Magnetic fastening ZB2490MH
Open the catalog to page 1
Compact measuring instrument with interface. Runs in battery mode or via mains unit Technical data and functions • Technical data and functions, as for ALMEMO® 2450 series • 2 ALMEMO® output sockets, suitable for all interface cables, network cables, trigger / relay cables • Complete sensor and device programming via interface • ALMEMO® DC socket for mains adapter. Technical data Technical data, as for ALMEMO® 2450 series Sensor power supply 9 V, maximum 0.5 A Power supply 10 to 30 VDC not electr. isolated suitable for all interface cables with option OA2450I only Internal RS485...
Open the catalog to page 2All Ahlborn catalogs and technical brochures
-
ALMEMO® 1020-2
3 Pages
-
ALMEMO® 2890-9
2 Pages
-
2690-8A
2 Pages
-
ALMEMO® 2470
3 Pages
-
ALMEMO® 5690 CPU
8 Pages
-
ALMEMO® 2490
2 Pages
-
ALMEMO® 202
2 Pages
-
ALMEMO® 710
3 Pages