Filter media for artificial respiratory devices
16Pages

{{requestButtons}}

Catalog excerpts

Filter media for artificial respiratory devices - 1

r MEDICAL FILTRATION TECHNOLOGY Filter media for respiratory systems and medical equipment *

Open the catalog to page 1
Filter media for artificial respiratory devices - 2

We are very proud to present you our new catalogue Medical Filtration Technology. Our program has been complemented by a variety of own new products. We can now offer you a complete product range for venting filters, breathing system filters and filter media for medical applications. Our experience of many years is the guarantee of high quality filter papers with properties tailored to different applications. Intensive Research and Development work in paper technology vouches for a continuous improvement of our filter paper to meet the requirements of tomorrow. As large portion of our...

Open the catalog to page 2
Filter media for artificial respiratory devices - 3

Quality Management System We are doing our utmost to realize this ambition and will do all that is necessary to have products and services meet even the highest expectations. At the end of the day, our business depends on your success. Quality control already begins during development. At this stage already, our chemists and technicians maintain close contact with our customers in order to tailor the right product for a given application. Raw materials are the basis for a consistent paper quality. This is why stringent quality checks are carried out for incoming goods. During production,...

Open the catalog to page 3
Filter media for artificial respiratory devices - 4

Invasive ventilation is used to assist or replace breathing when a person is unable to breathe adequately on their own. Additionally, in recent decades, Heat and Moisture Exchange (HME) devices have been employed increasingly for short-term use in anesthesia and long-term use in intensive care units. Our venting filter media are specifically developed for devices which are in common use in the treatment of patients with respiratory disorders. These filters offer protection by removing bacteria and viruses before they enter the patient's airway, bringing thus a crucial contribution in the...

Open the catalog to page 4
Filter media for artificial respiratory devices - 5

The use of a hydrophobic media as a venting and respiratory filter is necessary to provide excellent barrier to airborne microbial contaminants. Ahlstrom-Munksjo microglass filter media are manufactured from an advanced blend of borosilicate microglass fibers and acrylic resins PFOA-free. Our concept is to manufacture media in all efficiency ranges of interest- efficiencies from 99.90 % to 99.9999 % for 0.3 pm particle size - especially designed for CPAP and mechanical venting filters. Only high purity borosilicate glass fibers are employed, in thicknesses ranging from 0.2 to 2.0 pm,...

Open the catalog to page 5
Filter media for artificial respiratory devices - 6

Applications: Microfilter for supply air and venting filter for medical and pharmaceutical applications. Removal of particles and liquids (at low pressures) from air/gas supplies going to instruments that are sensitive to impurities /As MS-61 available with a length of 110 mm. Each filter is checked individually for retention.

Open the catalog to page 6
Filter media for artificial respiratory devices - 7

Applications: Microfiltration of supply air/gas (e.g. in CO2 incubators and oxygenators) and venting filter in medicine and for pharmaceutics production. Each filter is checked individually for retention.

Open the catalog to page 7
Filter media for artificial respiratory devices - 8

Applications: Microfiltration of volumes of up to 30 - 40 l/min for sterile and particle-free air or gases. Mainly used for cleaning exhaust air from suction devices. Each filter is checked individually for retention.

Open the catalog to page 8
Filter media for artificial respiratory devices - 9

Each filter is checked individually for retention.

Open the catalog to page 9
Filter media for artificial respiratory devices - 10

Specification Virogard Each filter is checked individually for retention. Lasertrap 100Applications: Complete elimination of particles, micro-organisms and odor in plumes from laser surgery and diathermy. Specification

Open the catalog to page 10
Filter media for artificial respiratory devices - 11

Product Dimensions Material Filter Male Nipple Olive male 11 mm 0, for tubes with internal 0 6-9 mm Female Nipple Olive MS-681 holders Tapered pipe thread 3/4" (KR 3/4")* nickel-plated brass nickel-plated brass Free inlet/ outlet (FI)** nickel-plated brass also available with clai tapered pipe thread The prefix L indicates holder half with lock clamps

Open the catalog to page 11
Filter media for artificial respiratory devices - 12

The filters with a pleated, hydrophobic mechanical filter membrane give the highest possible protection against contamination of the breathing system. Gard has such a mechanical membrane and is therefore very suitable. Bacstop and Bacstop Mini have an electrostatic filter membrane with a slightly lower filtration efficiency. Bacstop and Bacstop Mini will give sufficient protection during treatments that have low risks for contamination. The Gard models have several combinations of ISO connectors. The filters are available with a capnograph port. Bacstop Specification Bacstop Mini...

Open the catalog to page 12
Filter media for artificial respiratory devices - 13

The combination of a filter and aHME in the same housing is the ultimate solution for efficient microbial protection and humidification. Combigard is a combination of the excellent mechanical filter with the effective HME. Bacstop/HME is suitable for the treatments with lower risk for contamination but still with an effective humidification. The Combigard models have several combinations of ISO connectors. The filters are available with a capnograph port. Bacstop Humni Specification

Open the catalog to page 13
Filter media for artificial respiratory devices - 14

The HME inserts in the transparent housings are of 2 component micro-fibers and give a very low resistance. The resistance is low even after24 hours use. Together with an optimum moisture capacity it keeps the patient hydrated and the breathing system dry. The HMEs are available in a variety of sizes from Neogard for neonatal to HME Flex for adults.

Open the catalog to page 14
Filter media for artificial respiratory devices - 16

Ahlstrom-MunlcsjQ is a global leader in fiber-based materialSy supplying inno/ative and sustainable solutions to 'is customers. Our mission is to expand the role of fiber-based solutions (br sustainable everyday life. Our offering include filter materials, release liners, food and beverage processing materials, decor papery abrasive and tape backingsv electrotechnioal paper, glass fiber materials, medical fiber materials and solutions for diagnostics as well as a range of specialty papers for industrial and consumer end-uses. Our annual net sales are about EUR 3 billion and we employ some...

Open the catalog to page 16