1. Catalogs
  2. Aidian Oy
  3. QuikRead go CRP+Hb
video corpo

QuikRead go CRP+Hb

QuikRead go CRP+Hb

QuikRead go CRP+Hb

Product catalog summary
Overview
The QuikRead go CRP+Hb test is a diagnostic tool designed for primary healthcare settings, providing quantitative measurements of C-reactive protein (CRP) and Hemoglobin (Hb) from a single blood sample. This system includes a small instrument and a ready-to-use kit, facilitating ease of use and patient comfort.
Specifications
  • CRP measuring range: 5–200 mg/l
  • Hemoglobin measuring range: 50–245 g/l
  • Sample volume: 20 µl
Benefits
  • One analysis – two results: Provides reliable CRP and Hb results from a single analysis, eliminating the need for separate instruments.
  • Patient friendly: Requires only one sample, minimizing patient discomfort.
  • Easy to use: No manual steps are required, and the procedure includes automatic hematocrit correction for CRP results.
Procedure
  1. Place the sample into the buffer solution and close the cuvette tightly with a CRP reagent cap.
  2. Insert the cuvette into the measurement well of the instrument with the barcode facing you.
  3. Select 'Measure' on the display of the QuikRead go instrument.
  4. Results are displayed upon completion of the measurement.
Product Information
  • QuikRead go CRP+Hb kit, 50 tests (Cat. No. 140068)
  • QuikRead CRP Control 1 ml (Cat. No. 68296)
  • QuikRead go CRP Control High 1 ml (Cat. No. 137071)
  • QuikRead go Hb Control (Cat. No. 141154)
  • QuikRead Capillaries, 50 pcs (Cat. No. 67962)
  • QuikRead Plungers, 50 pcs (Cat. No. 67966)
  • QuikRead go Instrument (Cat. No. 133893)
References
  • Pepys MB. The acute phase response and C-reactive protein. Oxford Textbook of Medicine, 4th ed. 2003.
  • Weitkamp J-H, Achner JL. Diagnostic Use of C-Reactive Protein in Assessment of Neonatal Sepsis. NeoReviews 2005.
  • Gabay G, Kushner I. Acute-Phase Proteins and Other Systemic Responses to Inflammation. N Eng J Med 1999.
  • Hansson L-O, Lindqvist L. C-reactive protein: its role in the diagnosis and follow-up of infectious diseases. Curr Opin Inf Dis 1997.
  • Morley JJ, Kushner I. Serum C-reactive protein levels in disease. Ann N Y Acad Sci 1982.
Contact Information
Orion Diagnostica Oy, Koivu-Mankkaan tie 6 B, P.O. Box 83, FI-02101 Espoo, Finland. Tel. +358 10 4261, Fax +358 10 426 2794, www.oriondiagnostica.com, www.quikread.com
See more

Catalog excerpts

QuikRead go CRP+Hb-1

Get more information for diagnosis One analysis – two results Patient friendly – only one sample needed Easy to use – no manual steps

 Open the catalog to page 1
QuikRead go CRP+Hb-2

QuikRead go CRP+Hb test is a reliable and easy to use test for quantitative measurement of C-reactive protein (CRP) and Hemoglobin (Hb). The QuikRead go system – consisting of a small instrument and a readyto-use kit – is especially designed for use in primary health care settings. QuikRead go CRP+Hb kit, 50 tests • With capillaries and plungers QuikRead go CRP Control High 1 ml CRP is normally present in low concentrations in the blood of healthy people. CRP concentrations are markedly increased in bacterial infections, whereas viral infections mostly induce a very modest elevation or none at...

 Open the catalog to page 2

All Aidian Oy catalogs and technical brochures

  1. Easicult®

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.