Overview: The document provides detailed specifications and features of different ScanX models designed for dental imaging. Each model is tailored to specific practice needs, offering various processing capabilities and accessories.
ScanX Duo: This model is ideal for practices requiring chairside intraoral imaging. It features a compact design with two processing slots that can be used simultaneously, accommodating all intraoral sizes (0, 1, 2, 3, 4). It includes essential accessories such as power and USB cords, PSP guides, and cleaning materials.
ScanX Intraoral: Suitable for practices with digital pan or intraoral imaging needs, this model serves as a central digital processing unit. It has four processing slots and supports all intraoral sizes. Accessories include power supply, USB cord, multiple PSP guides, and cleaning supplies.
ScanX Classic: Designed for practices handling both intraoral and extraoral images, this model supports a wide range of sizes, including panoramic and cephalometric. It features four processing slots and includes comprehensive accessories similar to the other models.
Technical Specifications: All models operate on 100-240v AC, 50/60 Hz, with a resolution of up to 22 lp/mm and a theoretical resolution of 40 lp/mm. They comply with Class I Laser Product standards and include USB ports for connectivity.
Computer Requirements: The systems require Windows XP Professional or later, with a minimum of 3.0 GHz Intel CORE2 CPU, 2 GB RAM, and 120 GB hard drive. A USB 2.0 port, standard keyboard, mouse, and backup device are recommended.
See more

Catalog excerpts

ScanX Specifications Sell Sheet-1

® IMAGING UTILITY ROOM SPECIFICATIONS MERCHANDISE SELECT THE SCANX MODEL THAT BEST FITS YOUR PRACTICE AND YOUR BUDGET. SCANX INTRAORAL (PN B7100)* For practices that use a digital pan or have only intraoral imaging requirements. Also the perfect solution for creating a central digital processing location within your practice. Has four processing slots that can be used simultaneously, and accepts all intraoral sizes: 0, 1, 2, 3 and 4. SPECIFICATIONS Dimensions: 15 1/2" H x 15" W x 15 1/8" D Theoretical Resolution: 40 lp/mm (200 dpi) Accessories Included: Power Supply and (39.4 cm H x 38 cm W x 38.4 cm D) Port: USB Cord; Computer Connector Cord (USB); Weight: 43 lbs. (19.5 kg) Laser Classification: Class l Laser Product, Compliance with FDA 21 CFR 1040.10 and IEC 60825-1 4 each size 2 PSP Guides; 1 each size 0, Imaging Medium: Phosphor Storage Plates, Intraoral sizes 0, 1, 2, 3, 4 1 Plate Transfer Box; 1 Sample ScanX Electrical: 100-240v AC, 50/60 Hz Resolution: Up to 22 lp/mm (depending on scanning mode/pixel size selected) 1, and 3 PSP Guides; 20 each size 2 PSPs; 1 Box Barrier Envelopes Size 2 (qty. 300); Cleaning Sheet and 1 PSP Cleaning Wipe SCANX DUO (PN D1000)* For practices that require chairside intraoral imaging. Compact footprint takes up less than one square foot of space. Has two processing slots that can be used simultaneously, and accepts all intraoral sizes: 0, 1, 2, 3 and 4. SPECIFICATIONS Dimensions: 12" H x 10" W x 10 1/2" D Theoretical Resolution: 40 lp/mm (200 dpi) Intraoral sizes 0, 1, 2, 3, 4 (30.5 cm H x 25.4 cm W x 36.7 cm D) Port: USB Weight: 21 lbs. (9.5 kg) Laser Classification: Class l Laser Accessories Included: Power Cord; Computer Connector Cord (USB); 2 each size 2 PSP Guides; 1 each size 0 and 1 PSP Guides; 8 each size 2 PSPs; 1 Box Barrier Envelopes Size 2 (qty. 300); 1 PSP Table Mat; 1 Sample ScanX Cleaning Sheet and 1 PSP Cleaning Wipe Electrical: 100-240v AC, 50/60 Hz Product, Compliance with FDA 21 CFR 1040.10 and IEC 60825-1 Resolution: Up to 22 lp/mm (depending Imaging Medium: Two processing slots on scanning mode/pixel size selected) accept Phosphor Storage Plates; *ALL MODELS COME WITH A 24-MONTH WARRANTY

 Open the catalog to page 1
ScanX Specifications Sell Sheet-2

SCANX CLASSIC (PN B7200)* For practices that work with intraoral and extraoral images. No expensive conversion required. Simply replace film with the appropriate ScanX phosphor plate size. Use with film-based Panoramic or Cephalometric X-ray units to create crisp digital radiographs. Accepts all sizes: 0 to Cephalometric. Has four processing slots that can be used simultaneously, and accepts all intraoral sizes: 0, 1, 2, 3 and 4. SPECIFICATIONS Dimensions: 24" H x 15" W x 15 1/2" D (61 cm Imaging Medium: Phosphor Storage Plates; H x 38 cm W x 39.4 cm D) Intraoral sizes 0, 1, 2, 3, 4; Panoramic...

 Open the catalog to page 2

All Air Techniques catalogs and technical brochures

  1. Mojave

    6  Pages

  2. Lines Cleaner

    4  Pages

  3. Air Star Aero

    4  Pages

  4. ScanX Duo

    2  Pages

  5. DBSWIN

    6  Pages

  6. VISIX

    2  Pages

  7. STS 3

    2  Pages

  8. Mojave V3

    4  Pages

  9. VacStar 40

    2  Pages

  10. AirStar 10

    4  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.